Evaluation of the exposure time of a Bulk-Fill resin in deep preparations
Descripción del Articulo
Background: Bulk-fill composite resins (BF) are used in posterior restorations with extensive and deep preparations. One of the most outstanding benefits is that it can be used in increments...
Autores: | , , , , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2022 |
Institución: | Universidad Peruana Cayetano Heredia |
Repositorio: | Revistas - Universidad Peruana Cayetano Heredia |
Lenguaje: | español |
OAI Identifier: | oai:revistas.upch.edu.pe:article/4180 |
Enlace del recurso: | https://revistas.upch.edu.pe/index.php/REH/article/view/4180 |
Nivel de acceso: | acceso abierto |
Materia: | Dureza tiempo resinas compuestas polimerización Hardness time composite resins polymerization |
id |
REVUPCH_c87c6cf2b8d54a5fd98cd46684218dfb |
---|---|
oai_identifier_str |
oai:revistas.upch.edu.pe:article/4180 |
network_acronym_str |
REVUPCH |
network_name_str |
Revistas - Universidad Peruana Cayetano Heredia |
repository_id_str |
|
spelling |
Evaluation of the exposure time of a Bulk-Fill resin in deep preparationsEvaluación del tiempo de exposición de una resina Bulk-Fill en preparaciones profundasVásquez-Castro, EvaPortella-Atamari, JoséMelendez, DiegoRamirez-Vilchez, NicolDelgado-Cotrina, LeylaDurezatiemporesinas compuestaspolimerizaciónHardnesstimecomposite resinspolymerizationBackground: Bulk-fill composite resins (BF) are used in posterior restorations with extensive and deep preparations. One of the most outstanding benefits is that it can be used in increments of 4 to 5 mm, reducing clinical working time. However, in teeth with root canal treatment, these preparations could be deeper. Objectives: To determine the photoactivation time necessary to polymerize a Bulk-Fill resin located in deep areas. Material and Methods: In the present experimental in vitro study, specimens of Filtek One Bulk Fill composite resin (3M ESPE, St. Paul, USA) of 5x5x5 mm color A2 photoactivated at a distance/time of 0 mm/10 s, 0 mm/20 s, 3 mm/10 s, 3 mm/20 s, 3 mm/30 s and 3 mm/40 s (n=5) were fabricated. Surface microhardness was recorded on the surface and at the base of each specimen. Results: The highest microhardness value was recorded in group BF 0 mm/20 s and BF 3 mm/40 s (p<0.05), followed by groups BF 3 mm/20 s and BF 3 mm/30 s (p>0.05). The lowest microhardness values were found in the BF 0 mm/10 s and BF 3 mm/10 s groups. Conclusion: It takes 40 s of photoactivation to polymerize a Bulk-Fill resin located in deep areas, when the lamp is 3 mm away from the resin surface.Antecedentes: Las resinas compuestas tipo Bulk-Fill (BF) son usadas en piezas posteriores con preparaciones extensas y profundas. Uno de sus beneficios más resaltantes es que, puede ser utilizada en incrementos de 4 a 5 mm, disminuyendo el tiempo de trabajo clínico. Sin embargo, en dientes con tratamientos de conductos estas preparaciones podrían tener mayor profundidad. Objetivos: Determinar el tiempo de fotoactivación necesario para polimerizar una resina Bulk-Fill ubicada en zonas profundas. Material y Métodos: En el presente estudio experimental in vitro, se confeccionaron especímenes de resina compuesta Filtek One Bulk Fill (3M ESPE, St. Paul, EE.UU.) de 5x5x5 mm color A2 fotoactivado a una distancia/tiempo de 0 mm/10 s, 0 mm/20 s, 3 mm/10 s, 3 mm/20 s, 3 mm/30 s y 3 mm/40 s (n=5). La microdureza superficial se registró en la superficie y en la base de cada espécimen. Resultados: El mayor valor de microdureza se registró en el grupo BF 0 mm/20 s y BF 3 mm/40 s (p<0,05), seguido por los grupos BF 3 mm/20 s y BF 3 mm/30 s (p>0,05). Los menores valores de microdureza se encontraron en los grupos BF 0 mm/10 s y BF 3 mm/10 s. Conclusión: Se requiere de 40 s de fotoactivación para polimerizar una resina Bulk-Fill ubicada en zonas profundas, cuando la lámpara está a una distancia de 3 mm de la superficie de la resina.Universidad Peruana Cayetano Heredia2022-04-22info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistas.upch.edu.pe/index.php/REH/article/view/418010.20453/reh.v32i1.4180Revista Estomatológica Herediana; Vol. 32 No. 1 (2022): January-March; 30-35Revista Estomatológica Herediana; Vol. 32 Núm. 1 (2022): Enero-Marzo; 30-35Revista Estomatológica Herediana; v. 32 n. 1 (2022): Enero-Marzo; 30-352225-76161019-4355reponame:Revistas - Universidad Peruana Cayetano Herediainstname:Universidad Peruana Cayetano Herediainstacron:UPCHspahttps://revistas.upch.edu.pe/index.php/REH/article/view/4180/4734Derechos de autor 2022 Eva Vásquez-Castro, José Portella-Atamari, Diego Melendez, Nicol Ramirez-Vilchez, Leyla Delgado-Cotrinainfo:eu-repo/semantics/openAccessoai:revistas.upch.edu.pe:article/41802023-08-21T15:48:51Z |
dc.title.none.fl_str_mv |
Evaluation of the exposure time of a Bulk-Fill resin in deep preparations Evaluación del tiempo de exposición de una resina Bulk-Fill en preparaciones profundas |
title |
Evaluation of the exposure time of a Bulk-Fill resin in deep preparations |
spellingShingle |
Evaluation of the exposure time of a Bulk-Fill resin in deep preparations Vásquez-Castro, Eva Dureza tiempo resinas compuestas polimerización Hardness time composite resins polymerization |
title_short |
Evaluation of the exposure time of a Bulk-Fill resin in deep preparations |
title_full |
Evaluation of the exposure time of a Bulk-Fill resin in deep preparations |
title_fullStr |
Evaluation of the exposure time of a Bulk-Fill resin in deep preparations |
title_full_unstemmed |
Evaluation of the exposure time of a Bulk-Fill resin in deep preparations |
title_sort |
Evaluation of the exposure time of a Bulk-Fill resin in deep preparations |
dc.creator.none.fl_str_mv |
Vásquez-Castro, Eva Portella-Atamari, José Melendez, Diego Ramirez-Vilchez, Nicol Delgado-Cotrina, Leyla |
author |
Vásquez-Castro, Eva |
author_facet |
Vásquez-Castro, Eva Portella-Atamari, José Melendez, Diego Ramirez-Vilchez, Nicol Delgado-Cotrina, Leyla |
author_role |
author |
author2 |
Portella-Atamari, José Melendez, Diego Ramirez-Vilchez, Nicol Delgado-Cotrina, Leyla |
author2_role |
author author author author |
dc.subject.none.fl_str_mv |
Dureza tiempo resinas compuestas polimerización Hardness time composite resins polymerization |
topic |
Dureza tiempo resinas compuestas polimerización Hardness time composite resins polymerization |
description |
Background: Bulk-fill composite resins (BF) are used in posterior restorations with extensive and deep preparations. One of the most outstanding benefits is that it can be used in increments of 4 to 5 mm, reducing clinical working time. However, in teeth with root canal treatment, these preparations could be deeper. Objectives: To determine the photoactivation time necessary to polymerize a Bulk-Fill resin located in deep areas. Material and Methods: In the present experimental in vitro study, specimens of Filtek One Bulk Fill composite resin (3M ESPE, St. Paul, USA) of 5x5x5 mm color A2 photoactivated at a distance/time of 0 mm/10 s, 0 mm/20 s, 3 mm/10 s, 3 mm/20 s, 3 mm/30 s and 3 mm/40 s (n=5) were fabricated. Surface microhardness was recorded on the surface and at the base of each specimen. Results: The highest microhardness value was recorded in group BF 0 mm/20 s and BF 3 mm/40 s (p<0.05), followed by groups BF 3 mm/20 s and BF 3 mm/30 s (p>0.05). The lowest microhardness values were found in the BF 0 mm/10 s and BF 3 mm/10 s groups. Conclusion: It takes 40 s of photoactivation to polymerize a Bulk-Fill resin located in deep areas, when the lamp is 3 mm away from the resin surface. |
publishDate |
2022 |
dc.date.none.fl_str_mv |
2022-04-22 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
https://revistas.upch.edu.pe/index.php/REH/article/view/4180 10.20453/reh.v32i1.4180 |
url |
https://revistas.upch.edu.pe/index.php/REH/article/view/4180 |
identifier_str_mv |
10.20453/reh.v32i1.4180 |
dc.language.none.fl_str_mv |
spa |
language |
spa |
dc.relation.none.fl_str_mv |
https://revistas.upch.edu.pe/index.php/REH/article/view/4180/4734 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidad Peruana Cayetano Heredia |
publisher.none.fl_str_mv |
Universidad Peruana Cayetano Heredia |
dc.source.none.fl_str_mv |
Revista Estomatológica Herediana; Vol. 32 No. 1 (2022): January-March; 30-35 Revista Estomatológica Herediana; Vol. 32 Núm. 1 (2022): Enero-Marzo; 30-35 Revista Estomatológica Herediana; v. 32 n. 1 (2022): Enero-Marzo; 30-35 2225-7616 1019-4355 reponame:Revistas - Universidad Peruana Cayetano Heredia instname:Universidad Peruana Cayetano Heredia instacron:UPCH |
instname_str |
Universidad Peruana Cayetano Heredia |
instacron_str |
UPCH |
institution |
UPCH |
reponame_str |
Revistas - Universidad Peruana Cayetano Heredia |
collection |
Revistas - Universidad Peruana Cayetano Heredia |
repository.name.fl_str_mv |
|
repository.mail.fl_str_mv |
|
_version_ |
1844884491576803328 |
score |
12.828746 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).