Evaluation of the exposure time of a Bulk-Fill resin in deep preparations

Descripción del Articulo

Background: Bulk-fill composite  resins  (BF)  are  used  in  posterior  restorations  with  extensive  and  deep preparations. One of the most outstanding benefits is that it can be used in increments...

Descripción completa

Detalles Bibliográficos
Autores: Vásquez-Castro, Eva, Portella-Atamari, José, Melendez, Diego, Ramirez-Vilchez, Nicol, Delgado-Cotrina, Leyla
Formato: artículo
Fecha de Publicación:2022
Institución:Universidad Peruana Cayetano Heredia
Repositorio:Revistas - Universidad Peruana Cayetano Heredia
Lenguaje:español
OAI Identifier:oai:revistas.upch.edu.pe:article/4180
Enlace del recurso:https://revistas.upch.edu.pe/index.php/REH/article/view/4180
Nivel de acceso:acceso abierto
Materia:Dureza
tiempo
resinas compuestas
polimerización
Hardness
time
composite resins
polymerization
Descripción
Sumario:Background: Bulk-fill composite  resins  (BF)  are  used  in  posterior  restorations  with  extensive  and  deep preparations. One of the most outstanding benefits is that it can be used in increments of 4 to 5 mm, reducing clinical working time. However, in teeth with root canal treatment, these preparations could be deeper. Objectives: To determine the photoactivation time necessary to polymerize a Bulk-Fill resin located in deep areas. Material and Methods: In the present experimental in vitro study, specimens of Filtek One Bulk Fill composite resin (3M ESPE, St. Paul, USA) of 5x5x5 mm color A2 photoactivated at a distance/time of 0 mm/10 s, 0 mm/20 s, 3 mm/10 s, 3 mm/20 s, 3 mm/30 s and 3 mm/40 s (n=5) were fabricated. Surface microhardness was recorded on the surface and at the base of each specimen. Results: The highest microhardness value was recorded in group BF 0 mm/20 s and BF 3 mm/40 s (p<0.05), followed by groups BF 3 mm/20 s and BF 3 mm/30 s (p>0.05). The lowest microhardness values were found in the BF 0 mm/10 s and BF 3 mm/10 s groups. Conclusion: It takes 40 s of photoactivation to polymerize a Bulk-Fill resin located in deep areas, when the lamp is 3 mm away from the resin surface.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).