Interference generated by lipemia in the measurement of biochemical constituents
Descripción del Articulo
Turbidity due to lipemia in diagnostic samples is one of the main causes of the appearance of clinically significant biases in the measurement of biochemical magnitudes. Objective. To assess the interference by lipemia in the measurement of 25 biochemical constituents in two analyzers with dry chemi...
Autores: | , , , , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2023 |
Institución: | Universidad Nacional Mayor de San Marcos |
Repositorio: | Revistas - Universidad Nacional Mayor de San Marcos |
Lenguaje: | español |
OAI Identifier: | oai:ojs.csi.unmsm:article/25406 |
Enlace del recurso: | https://revistasinvestigacion.unmsm.edu.pe/index.php/anales/article/view/25406 |
Nivel de acceso: | acceso abierto |
Materia: | Sesgo lipemia errores diagnósticos lipoproteínas pruebas de química clínica Bias diagnostic errors lipoproteins clinical chemistry tests |
Sumario: | Turbidity due to lipemia in diagnostic samples is one of the main causes of the appearance of clinically significant biases in the measurement of biochemical magnitudes. Objective. To assess the interference by lipemia in the measurement of 25 biochemical constituents in two analyzers with dry chemistry technology (Vitros 7600®) and liquid chemistry (Atellica® Solution). Methods. Pre-experimental study with pre and post test. Increasing amounts of a parenteral nutrition lipid emulsion were added to seven aliquots of pooled sera and the influence of the interferent on 25 constituents was determined in duplicate. The relative percentage deviation of the concentration of the constituent due to the influence of turbidity with respect to a sample without interference, was calculated. Tolerance limits for interference were established using three criteria: reagent distributor, desirable systematic error, and maximum permissible error. Results. The constituents that presented the greatest biases for the liquid chemistry analyzer were: Phosphorus (-84.72%), ALT (+81.25%) and AST (-75.76%), while for the dry chemistry platform the constituents, ALT (-79.41%), CK (-28.92%) and lipase (+24.85%). Significant interference was detected in a different number of constituents according to the tolerable limit criteria used. Conclusions. The different results found according to the methodology and the analyzer used, in addition to the lack of replicability of the tests for the evaluation of interference by lipemia, originates the need to harmonize the processes and establish identical limits of tolerable interference between the laboratories and suppliers of inputs. |
---|
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).