MONTMORILLONITE APPLICATION IN ELECTROCHEMICAL TREATMENT EFFLUENT

Descripción del Articulo

In this work it is proposed the usage of montmorillonile for zinc and copper ion removal from electrochemicai effluents. The initial concentrations of zinc etfluents analyzed in this work, varied between 1O and 94 ppm in Zn2+, being the pH between values 6-7. The obtained percentage of removal with...

Descripción completa

Detalles Bibliográficos
Autores: Zárate A., Gisela, Osario A., Ana, Vela C., Rosemary, Carhuancho A., Maria H.
Formato: artículo
Fecha de Publicación:2006
Institución:Universidad Nacional Mayor de San Marcos
Repositorio:Revistas - Universidad Nacional Mayor de San Marcos
Lenguaje:español
OAI Identifier:oai:ojs.csi.unmsm:article/4067
Enlace del recurso:https://revistasinvestigacion.unmsm.edu.pe/index.php/quim/article/view/4067
Nivel de acceso:acceso abierto
Materia:Montrnorillonite
Zinc
Cooper
Effluents
Electrochemical.
Montmorillonita
Cobre
Efluentes
Electroquímicos.
id REVUNMSM_c4ebac26cb483d5179f83e587405281a
oai_identifier_str oai:ojs.csi.unmsm:article/4067
network_acronym_str REVUNMSM
network_name_str Revistas - Universidad Nacional Mayor de San Marcos
repository_id_str
spelling MONTMORILLONITE APPLICATION IN ELECTROCHEMICAL TREATMENT EFFLUENTAPLICACIÓN DE LA MONTMORILLONITA EN EL TRATAMIENTO DE EFLUENTES ELECTROQUÍMICOSZárate A., GiselaOsario A., AnaVela C., RosemaryCarhuancho A., Maria H.MontrnorilloniteZincCooperEffluentsElectrochemical.MontmorillonitaZincCobreEfluentesElectroquímicos.In this work it is proposed the usage of montmorillonile for zinc and copper ion removal from electrochemicai effluents. The initial concentrations of zinc etfluents analyzed in this work, varied between 1O and 94 ppm in Zn2+, being the pH between values 6-7. The obtained percentage of removal with calcic and sodic montmorillonite surpassed in all the cases 98%. The initial concenlrations of copper effluents oscillated between 16 and 160 ppm. in Cu2•. In the treatment of these effluents with calcic montmorillonite an elimination between 98.5 and 85.5% was reached al pH values between 4-5. In both cases it was used a relation of 5 grams ot clay 1200 milliliters of effluent for one hour agitation .En este trabajo se propone la aplicación de la montmorillonita para la remoción de iones cinc y cobre presentes en efluentes electroquimicos. Las concentraciones iniciales de los efluentes de cinc con los cuales se trabajó, variaron entre 1O y 94 ppm. en Zn2- , encontrándose los valores de pH entre 6-7. Los porcentajes de remoción obtenidos con montmorillonita cálcica y sódica superaron en todos los casos el 98%. Las concentraciones iniciales de los efluentes de cobre oscilaron entre 16 y 160 ppm. en Cu2•. En el tratamiento de estos efluentes con montmorillonita de tipo cálcica se logró una eliminación entre el 98,5 y 85,5%, a valores de pH regulados entre 4-5. En ambos casos se utilizó una relación de 5 gramos de arcilla /200 mL de efluente con una agitación de una hora.Universidad Nacional Mayor de San Marcos2006-08-14info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistasinvestigacion.unmsm.edu.pe/index.php/quim/article/view/4067Revista Peruana de Química e Ingeniería Química; Vol. 9 No. 1 (2006); 33-36Revista Peruana de Química e Ingeniería Química; Vol. 9 Núm. 1 (2006); 33-361609-75991726-2208reponame:Revistas - Universidad Nacional Mayor de San Marcosinstname:Universidad Nacional Mayor de San Marcosinstacron:UNMSMspahttps://revistasinvestigacion.unmsm.edu.pe/index.php/quim/article/view/4067/3245Derechos de autor 2006 Gisela Zárate A., Ana Osario A., Rosemary Vela C., Maria H. Carhuancho A.https://creativecommons.org/licenses/by-nc-sa/4.0info:eu-repo/semantics/openAccessoai:ojs.csi.unmsm:article/40672020-05-10T15:09:56Z
dc.title.none.fl_str_mv MONTMORILLONITE APPLICATION IN ELECTROCHEMICAL TREATMENT EFFLUENT
APLICACIÓN DE LA MONTMORILLONITA EN EL TRATAMIENTO DE EFLUENTES ELECTROQUÍMICOS
title MONTMORILLONITE APPLICATION IN ELECTROCHEMICAL TREATMENT EFFLUENT
spellingShingle MONTMORILLONITE APPLICATION IN ELECTROCHEMICAL TREATMENT EFFLUENT
Zárate A., Gisela
Montrnorillonite
Zinc
Cooper
Effluents
Electrochemical.
Montmorillonita
Zinc
Cobre
Efluentes
Electroquímicos.
title_short MONTMORILLONITE APPLICATION IN ELECTROCHEMICAL TREATMENT EFFLUENT
title_full MONTMORILLONITE APPLICATION IN ELECTROCHEMICAL TREATMENT EFFLUENT
title_fullStr MONTMORILLONITE APPLICATION IN ELECTROCHEMICAL TREATMENT EFFLUENT
title_full_unstemmed MONTMORILLONITE APPLICATION IN ELECTROCHEMICAL TREATMENT EFFLUENT
title_sort MONTMORILLONITE APPLICATION IN ELECTROCHEMICAL TREATMENT EFFLUENT
dc.creator.none.fl_str_mv Zárate A., Gisela
Osario A., Ana
Vela C., Rosemary
Carhuancho A., Maria H.
author Zárate A., Gisela
author_facet Zárate A., Gisela
Osario A., Ana
Vela C., Rosemary
Carhuancho A., Maria H.
author_role author
author2 Osario A., Ana
Vela C., Rosemary
Carhuancho A., Maria H.
author2_role author
author
author
dc.subject.none.fl_str_mv Montrnorillonite
Zinc
Cooper
Effluents
Electrochemical.
Montmorillonita
Zinc
Cobre
Efluentes
Electroquímicos.
topic Montrnorillonite
Zinc
Cooper
Effluents
Electrochemical.
Montmorillonita
Zinc
Cobre
Efluentes
Electroquímicos.
description In this work it is proposed the usage of montmorillonile for zinc and copper ion removal from electrochemicai effluents. The initial concentrations of zinc etfluents analyzed in this work, varied between 1O and 94 ppm in Zn2+, being the pH between values 6-7. The obtained percentage of removal with calcic and sodic montmorillonite surpassed in all the cases 98%. The initial concenlrations of copper effluents oscillated between 16 and 160 ppm. in Cu2•. In the treatment of these effluents with calcic montmorillonite an elimination between 98.5 and 85.5% was reached al pH values between 4-5. In both cases it was used a relation of 5 grams ot clay 1200 milliliters of effluent for one hour agitation .
publishDate 2006
dc.date.none.fl_str_mv 2006-08-14
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://revistasinvestigacion.unmsm.edu.pe/index.php/quim/article/view/4067
url https://revistasinvestigacion.unmsm.edu.pe/index.php/quim/article/view/4067
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv https://revistasinvestigacion.unmsm.edu.pe/index.php/quim/article/view/4067/3245
dc.rights.none.fl_str_mv Derechos de autor 2006 Gisela Zárate A., Ana Osario A., Rosemary Vela C., Maria H. Carhuancho A.
https://creativecommons.org/licenses/by-nc-sa/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Derechos de autor 2006 Gisela Zárate A., Ana Osario A., Rosemary Vela C., Maria H. Carhuancho A.
https://creativecommons.org/licenses/by-nc-sa/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidad Nacional Mayor de San Marcos
publisher.none.fl_str_mv Universidad Nacional Mayor de San Marcos
dc.source.none.fl_str_mv Revista Peruana de Química e Ingeniería Química; Vol. 9 No. 1 (2006); 33-36
Revista Peruana de Química e Ingeniería Química; Vol. 9 Núm. 1 (2006); 33-36
1609-7599
1726-2208
reponame:Revistas - Universidad Nacional Mayor de San Marcos
instname:Universidad Nacional Mayor de San Marcos
instacron:UNMSM
instname_str Universidad Nacional Mayor de San Marcos
instacron_str UNMSM
institution UNMSM
reponame_str Revistas - Universidad Nacional Mayor de San Marcos
collection Revistas - Universidad Nacional Mayor de San Marcos
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1795238290632212480
score 13.90198
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).