Design and construction of the small wind generator called “AR-SF-500” for the ore milling to a laborator y scale

Descripción del Articulo

The small wind generator called “AR-SFWP- 500” has a dynamo that generated a potency of 500 watts, which characterize for having in its internal structure, the called “permanent magnet” for working with small wind generators, such as employing in rural zones, where there is a lack of electric energy...

Descripción completa

Detalles Bibliográficos
Autores: Romero Baylón, Alfonso, Flores Chávez, Silvana, Pacheco, Werner
Formato: artículo
Fecha de Publicación:2011
Institución:Universidad Nacional Mayor de San Marcos
Repositorio:Revistas - Universidad Nacional Mayor de San Marcos
Lenguaje:español
OAI Identifier:oai:ojs.csi.unmsm:article/6212
Enlace del recurso:https://revistasinvestigacion.unmsm.edu.pe/index.php/idata/article/view/6212
Nivel de acceso:acceso abierto
Materia:Wind energy
wind generator
ore milling.
Energía eólica
microaerogenerador
molino de mineral
id REVUNMSM_74e3813fb6b82507204d04b24b5f0e3a
oai_identifier_str oai:ojs.csi.unmsm:article/6212
network_acronym_str REVUNMSM
network_name_str Revistas - Universidad Nacional Mayor de San Marcos
repository_id_str
spelling Design and construction of the small wind generator called “AR-SF-500” for the ore milling to a laborator y scaleDiseño y construcción de microaerogenerador “ar -sf -wp -500” para la molienda de mineral a escala de laboratorioRomero Baylón, AlfonsoFlores Chávez, SilvanaPacheco, WernerWind energywind generatorore milling.Energía eólicamicroaerogeneradormolino de mineralThe small wind generator called “AR-SFWP- 500” has a dynamo that generated a potency of 500 watts, which characterize for having in its internal structure, the called “permanent magnet” for working with small wind generators, such as employing in rural zones, where there is a lack of electric energy. In this sense, the purpose of the paper, treats explaining the process of design and construction of the Small Wind Generator AR-SFWP- 500, whose principle of functioning is based in transform the wind energy in electric energy, in such manner, this kind of energy has been used for moving the ore milling at laboratory scale, which uses an electric motor of a lower potency.El micro-aerogenerador, denominado AR-SFWP- 500, posee un dínamo que genera una potencia de 500 Watts, el cual se caracteriza por tener en su estructura interna, imanes permanentes (GIP) para trabajar con microaerogeneradores, como para emplearlos en zonas rurales, donde hay carencia de energía eléctrica. El propósito del artículo, consiste en explicar el proceso del diseño y la construcción del Microaerogenerador AR-SF-WP-500, cuyo principio de funcionamiento se basa en convertir la energía eólica en energía eléctrica, de tal manera que este tipo de energía se use para mover el molino de mineral de escala de laboratorio, el cual emplea un motor eléctrico de baja potencia.Facultad de Ingeniería Industrial, Universidad Nacional Mayor de San Marcos2011-07-15info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistasinvestigacion.unmsm.edu.pe/index.php/idata/article/view/621210.15381/idata.v14i1.6212Industrial Data; Vol. 14 No. 1 (2011); 062-068Industrial Data; Vol. 14 Núm. 1 (2011); 062-0681810-99931560-9146reponame:Revistas - Universidad Nacional Mayor de San Marcosinstname:Universidad Nacional Mayor de San Marcosinstacron:UNMSMspahttps://revistasinvestigacion.unmsm.edu.pe/index.php/idata/article/view/6212/5417Derechos de autor 2011 Alfonso Romero Baylón, Silvana Flores Chávez, Werner Pachecohttps://creativecommons.org/licenses/by-nc-sa/4.0info:eu-repo/semantics/openAccessoai:ojs.csi.unmsm:article/62122020-06-13T22:00:47Z
dc.title.none.fl_str_mv Design and construction of the small wind generator called “AR-SF-500” for the ore milling to a laborator y scale
Diseño y construcción de microaerogenerador “ar -sf -wp -500” para la molienda de mineral a escala de laboratorio
title Design and construction of the small wind generator called “AR-SF-500” for the ore milling to a laborator y scale
spellingShingle Design and construction of the small wind generator called “AR-SF-500” for the ore milling to a laborator y scale
Romero Baylón, Alfonso
Wind energy
wind generator
ore milling.
Energía eólica
microaerogenerador
molino de mineral
title_short Design and construction of the small wind generator called “AR-SF-500” for the ore milling to a laborator y scale
title_full Design and construction of the small wind generator called “AR-SF-500” for the ore milling to a laborator y scale
title_fullStr Design and construction of the small wind generator called “AR-SF-500” for the ore milling to a laborator y scale
title_full_unstemmed Design and construction of the small wind generator called “AR-SF-500” for the ore milling to a laborator y scale
title_sort Design and construction of the small wind generator called “AR-SF-500” for the ore milling to a laborator y scale
dc.creator.none.fl_str_mv Romero Baylón, Alfonso
Flores Chávez, Silvana
Pacheco, Werner
author Romero Baylón, Alfonso
author_facet Romero Baylón, Alfonso
Flores Chávez, Silvana
Pacheco, Werner
author_role author
author2 Flores Chávez, Silvana
Pacheco, Werner
author2_role author
author
dc.subject.none.fl_str_mv Wind energy
wind generator
ore milling.
Energía eólica
microaerogenerador
molino de mineral
topic Wind energy
wind generator
ore milling.
Energía eólica
microaerogenerador
molino de mineral
description The small wind generator called “AR-SFWP- 500” has a dynamo that generated a potency of 500 watts, which characterize for having in its internal structure, the called “permanent magnet” for working with small wind generators, such as employing in rural zones, where there is a lack of electric energy. In this sense, the purpose of the paper, treats explaining the process of design and construction of the Small Wind Generator AR-SFWP- 500, whose principle of functioning is based in transform the wind energy in electric energy, in such manner, this kind of energy has been used for moving the ore milling at laboratory scale, which uses an electric motor of a lower potency.
publishDate 2011
dc.date.none.fl_str_mv 2011-07-15
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://revistasinvestigacion.unmsm.edu.pe/index.php/idata/article/view/6212
10.15381/idata.v14i1.6212
url https://revistasinvestigacion.unmsm.edu.pe/index.php/idata/article/view/6212
identifier_str_mv 10.15381/idata.v14i1.6212
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv https://revistasinvestigacion.unmsm.edu.pe/index.php/idata/article/view/6212/5417
dc.rights.none.fl_str_mv Derechos de autor 2011 Alfonso Romero Baylón, Silvana Flores Chávez, Werner Pacheco
https://creativecommons.org/licenses/by-nc-sa/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Derechos de autor 2011 Alfonso Romero Baylón, Silvana Flores Chávez, Werner Pacheco
https://creativecommons.org/licenses/by-nc-sa/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Facultad de Ingeniería Industrial, Universidad Nacional Mayor de San Marcos
publisher.none.fl_str_mv Facultad de Ingeniería Industrial, Universidad Nacional Mayor de San Marcos
dc.source.none.fl_str_mv Industrial Data; Vol. 14 No. 1 (2011); 062-068
Industrial Data; Vol. 14 Núm. 1 (2011); 062-068
1810-9993
1560-9146
reponame:Revistas - Universidad Nacional Mayor de San Marcos
instname:Universidad Nacional Mayor de San Marcos
instacron:UNMSM
instname_str Universidad Nacional Mayor de San Marcos
instacron_str UNMSM
institution UNMSM
reponame_str Revistas - Universidad Nacional Mayor de San Marcos
collection Revistas - Universidad Nacional Mayor de San Marcos
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1795238300032696320
score 13.905277
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).