Critical Evaluation of the Ultrsdonographic Biophysical Profile Score, Their Interpretation and Value. Hospital Guillermo Almenara, Lima-Perú

Descripción del Articulo

OBJECTIVES: To make a critical evaluation of the performance of Ultrasonographic Biophysical Profile (UBP) as a method for antepartum fetal evaluation; to define their main outcome measures as well as their interpretation, and propose a fetal well-being assessment algorithm which considers the score...

Descripción completa

Detalles Bibliográficos
Autores: Alegría Guerrero, Raúl, Donayre, Abelardo, Paz Castillo, Julio
Formato: artículo
Fecha de Publicación:1999
Institución:Universidad Nacional Mayor de San Marcos
Repositorio:Revistas - Universidad Nacional Mayor de San Marcos
Lenguaje:español
OAI Identifier:oai:ojs.csi.unmsm:article/4450
Enlace del recurso:https://revistasinvestigacion.unmsm.edu.pe/index.php/anales/article/view/4450
Nivel de acceso:acceso abierto
Materia:Utrasonography
Fetus
Prenatal Care
Pregnancy
Ultrasonografía
Feto
Atención Prenatal
Embarazo
Descripción
Sumario:OBJECTIVES: To make a critical evaluation of the performance of Ultrasonographic Biophysical Profile (UBP) as a method for antepartum fetal evaluation; to define their main outcome measures as well as their interpretation, and propose a fetal well-being assessment algorithm which considers the score obtained. MATERIAL AND METHODS: Observational, prospective blind study. Since october, 1997 to september, 1998, 120 women with a gestational age ³28 weeks who required fetal well-being assessment to decide pregnancy interruption, at the High-Risk-Obstetrics Department, Hospital Guillermo Almenara, Lima. We evaluate the difficulties and benefits obtained with the ultrasonographic assessment of baseline fetal heart rate and heart reactivity; and the value of ultrasonographic qualitative assessment of amniotic fluid volume, placentary senescence and early placentary aging; and the value of establishing a cutpoint to define high risk pregnancies. RESULTS: Using this way, UBP showed an high sensitivity (87,5%), a good predictive value (63,6%) and an important decrease of false positive and false negative results (36,3% and 2,0%, respectively). CONCLUSIONS: Used in conjunction with a fetal well-being assessment algorithm and with an individualized approach to each woman, UBP was efficient and effective.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).