Exportación Completada — 

Middle plane absorbed dose calculation applying in vivo dosimetry during total body irradiation

Descripción del Articulo

Total Body Irradiation (ICT) with photon beams is a technique used in the treatment of haematopoietic diseases in order to achieve sterile conditions necessary to perform bone marrow transplants. For this dose should be prescribed in the plane of the patient and have a roughly accurate distribution...

Descripción completa

Detalles Bibliográficos
Autores: Ubillús, F., Márquez, J., Herrera, C.
Formato: artículo
Fecha de Publicación:2013
Institución:Universidad Nacional Mayor de San Marcos
Repositorio:Revistas - Universidad Nacional Mayor de San Marcos
Lenguaje:español
OAI Identifier:oai:ojs.csi.unmsm:article/9180
Enlace del recurso:https://revistasinvestigacion.unmsm.edu.pe/index.php/fisica/article/view/9180
Nivel de acceso:acceso abierto
Materia:Total body irradiation
in vivo dosimetry
OSL dosimetry.
Irradiación de cuerpo total
dosímetría in vivo
dosimetría OSL.
Descripción
Sumario:Total Body Irradiation (ICT) with photon beams is a technique used in the treatment of haematopoietic diseases in order to achieve sterile conditions necessary to perform bone marrow transplants. For this dose should be prescribed in the plane of the patient and have a roughly accurate distribution of the dose (± 5 % deviation from the prescribed dose) throughout the body, but due to the irregular geometry of the patient can not use planning systems treatment, which is why it resorts to in vivo dosimetry. The application of the method of dosimetry in vivo is an algorithm based on the values of entry and exit doses measured by the detectors optically stimulated luminescence OSL (Al2 O3 :C) located on the surface of a phantom uniformity, which is irradiated with beams of 6 MV photons generated by the Siemens Primus Linear Accelerator Mid (Mevatron). Subsequently these results are compared with the dose readings taken by an ionization chamber (PTW-Freiburg TW31010 Model 2167) located in the middle plane. The same shall be for the case where the beam is attenuated by 22.72 %, using a lead shielding of 4 mm (used as protection of critical organs), checking deviations were less than ± 10 % in both cases. Therefore, the use of these detectors can develop an alternative dosimetric approach, which helps ensure the quality of treatment.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).