Middle plane absorbed dose calculation applying in vivo dosimetry during total body irradiation
Descripción del Articulo
Total Body Irradiation (ICT) with photon beams is a technique used in the treatment of haematopoietic diseases in order to achieve sterile conditions necessary to perform bone marrow transplants. For this dose should be prescribed in the plane of the patient and have a roughly accurate distribution...
Autores: | , , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2013 |
Institución: | Universidad Nacional Mayor de San Marcos |
Repositorio: | Revistas - Universidad Nacional Mayor de San Marcos |
Lenguaje: | español |
OAI Identifier: | oai:ojs.csi.unmsm:article/9180 |
Enlace del recurso: | https://revistasinvestigacion.unmsm.edu.pe/index.php/fisica/article/view/9180 |
Nivel de acceso: | acceso abierto |
Materia: | Total body irradiation in vivo dosimetry OSL dosimetry. Irradiación de cuerpo total dosímetría in vivo dosimetría OSL. |
id |
REVUNMSM_39d31417d748678a80d3b4038893f1ac |
---|---|
oai_identifier_str |
oai:ojs.csi.unmsm:article/9180 |
network_acronym_str |
REVUNMSM |
network_name_str |
Revistas - Universidad Nacional Mayor de San Marcos |
repository_id_str |
|
spelling |
Middle plane absorbed dose calculation applying in vivo dosimetry during total body irradiationCálculo de la dosis absorbida en el plano medio aplicando el método de dosimetría in vivo para el caso de la irradiación de cuerpo totalUbillús, F.Márquez, J.Herrera, C.Total body irradiationin vivo dosimetryOSL dosimetry.Irradiación de cuerpo totaldosímetría in vivodosimetría OSL.Total Body Irradiation (ICT) with photon beams is a technique used in the treatment of haematopoietic diseases in order to achieve sterile conditions necessary to perform bone marrow transplants. For this dose should be prescribed in the plane of the patient and have a roughly accurate distribution of the dose (± 5 % deviation from the prescribed dose) throughout the body, but due to the irregular geometry of the patient can not use planning systems treatment, which is why it resorts to in vivo dosimetry. The application of the method of dosimetry in vivo is an algorithm based on the values of entry and exit doses measured by the detectors optically stimulated luminescence OSL (Al2 O3 :C) located on the surface of a phantom uniformity, which is irradiated with beams of 6 MV photons generated by the Siemens Primus Linear Accelerator Mid (Mevatron). Subsequently these results are compared with the dose readings taken by an ionization chamber (PTW-Freiburg TW31010 Model 2167) located in the middle plane. The same shall be for the case where the beam is attenuated by 22.72 %, using a lead shielding of 4 mm (used as protection of critical organs), checking deviations were less than ± 10 % in both cases. Therefore, the use of these detectors can develop an alternative dosimetric approach, which helps ensure the quality of treatment.La Irradiación de Cuerpo Total (ICT) con haces de fotones es una técnica utilizada en el tratamiento de enfermedades hematopoyéticas, a fin de lograr las condiciones de esterilidad necesarias para realizar trasplantes de médula ósea. Para esto se debe prescribir la dosis en el plano medio del paciente y tener una distribución aproximadamente exacta de la dosis (desviación del ± 5 % de la dosis prescrita) en todo el cuerpo, pero debido a la geometría irregular del paciente no es posible utilizar sistemas de planificación de tratamiento; es por esto que se recurre a la dosimetría in vivo. La aplicación del método de dosimetría in vivo consiste en un algoritmo de cálculo basado en los valores de dosis de entrada y salida medidos por los detectores de Luminiscencia Ópticamente Estimulada OSL (Al2 O3 :C) ubicados en las superficies de un fantoma homogéno, el cual es irradiado con haces de fotones de 6 MV generados por el Acelerador Lineal Siemens Primus Mid (Mevatron). Posteriormente estos resultados son comparados con las lecturas de dosis tomadas por una cámara de ionización (PTW Freiburg Modelo TW31010-2167) ubicada en plano medio. De igual forma se procede para el caso en el que el haz es atenuado en un 22.72 %, empleando una protección de plomo de 4 mm (utilizado como protección de órganos críticos), comprobándose desviaciones menores al ± 10 % en ambos casos. Por tanto, el uso de estos detectores permite desarrollar un método dosimétrico alternativo, que contribuye a garantizar la calidad del tratamiento.Universidad Nacional Mayor de San Marcos2013-07-15info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistasinvestigacion.unmsm.edu.pe/index.php/fisica/article/view/918010.15381/rif.v16i01.9180Revista de Investigación de Física; Vol. 16 No. 01 (2013); 1-7Revista de Investigación de Física; Vol. 16 Núm. 01 (2013); 1-71728-29771605-7724reponame:Revistas - Universidad Nacional Mayor de San Marcosinstname:Universidad Nacional Mayor de San Marcosinstacron:UNMSMspahttps://revistasinvestigacion.unmsm.edu.pe/index.php/fisica/article/view/9180/8008Derechos de autor 2013 F. Ubillús, J. Márquez, C. Herrerahttps://creativecommons.org/licenses/by-nc-sa/4.0info:eu-repo/semantics/openAccessoai:ojs.csi.unmsm:article/91802020-09-03T20:07:20Z |
dc.title.none.fl_str_mv |
Middle plane absorbed dose calculation applying in vivo dosimetry during total body irradiation Cálculo de la dosis absorbida en el plano medio aplicando el método de dosimetría in vivo para el caso de la irradiación de cuerpo total |
title |
Middle plane absorbed dose calculation applying in vivo dosimetry during total body irradiation |
spellingShingle |
Middle plane absorbed dose calculation applying in vivo dosimetry during total body irradiation Ubillús, F. Total body irradiation in vivo dosimetry OSL dosimetry. Irradiación de cuerpo total dosímetría in vivo dosimetría OSL. |
title_short |
Middle plane absorbed dose calculation applying in vivo dosimetry during total body irradiation |
title_full |
Middle plane absorbed dose calculation applying in vivo dosimetry during total body irradiation |
title_fullStr |
Middle plane absorbed dose calculation applying in vivo dosimetry during total body irradiation |
title_full_unstemmed |
Middle plane absorbed dose calculation applying in vivo dosimetry during total body irradiation |
title_sort |
Middle plane absorbed dose calculation applying in vivo dosimetry during total body irradiation |
dc.creator.none.fl_str_mv |
Ubillús, F. Márquez, J. Herrera, C. |
author |
Ubillús, F. |
author_facet |
Ubillús, F. Márquez, J. Herrera, C. |
author_role |
author |
author2 |
Márquez, J. Herrera, C. |
author2_role |
author author |
dc.subject.none.fl_str_mv |
Total body irradiation in vivo dosimetry OSL dosimetry. Irradiación de cuerpo total dosímetría in vivo dosimetría OSL. |
topic |
Total body irradiation in vivo dosimetry OSL dosimetry. Irradiación de cuerpo total dosímetría in vivo dosimetría OSL. |
description |
Total Body Irradiation (ICT) with photon beams is a technique used in the treatment of haematopoietic diseases in order to achieve sterile conditions necessary to perform bone marrow transplants. For this dose should be prescribed in the plane of the patient and have a roughly accurate distribution of the dose (± 5 % deviation from the prescribed dose) throughout the body, but due to the irregular geometry of the patient can not use planning systems treatment, which is why it resorts to in vivo dosimetry. The application of the method of dosimetry in vivo is an algorithm based on the values of entry and exit doses measured by the detectors optically stimulated luminescence OSL (Al2 O3 :C) located on the surface of a phantom uniformity, which is irradiated with beams of 6 MV photons generated by the Siemens Primus Linear Accelerator Mid (Mevatron). Subsequently these results are compared with the dose readings taken by an ionization chamber (PTW-Freiburg TW31010 Model 2167) located in the middle plane. The same shall be for the case where the beam is attenuated by 22.72 %, using a lead shielding of 4 mm (used as protection of critical organs), checking deviations were less than ± 10 % in both cases. Therefore, the use of these detectors can develop an alternative dosimetric approach, which helps ensure the quality of treatment. |
publishDate |
2013 |
dc.date.none.fl_str_mv |
2013-07-15 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
https://revistasinvestigacion.unmsm.edu.pe/index.php/fisica/article/view/9180 10.15381/rif.v16i01.9180 |
url |
https://revistasinvestigacion.unmsm.edu.pe/index.php/fisica/article/view/9180 |
identifier_str_mv |
10.15381/rif.v16i01.9180 |
dc.language.none.fl_str_mv |
spa |
language |
spa |
dc.relation.none.fl_str_mv |
https://revistasinvestigacion.unmsm.edu.pe/index.php/fisica/article/view/9180/8008 |
dc.rights.none.fl_str_mv |
Derechos de autor 2013 F. Ubillús, J. Márquez, C. Herrera https://creativecommons.org/licenses/by-nc-sa/4.0 info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Derechos de autor 2013 F. Ubillús, J. Márquez, C. Herrera https://creativecommons.org/licenses/by-nc-sa/4.0 |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidad Nacional Mayor de San Marcos |
publisher.none.fl_str_mv |
Universidad Nacional Mayor de San Marcos |
dc.source.none.fl_str_mv |
Revista de Investigación de Física; Vol. 16 No. 01 (2013); 1-7 Revista de Investigación de Física; Vol. 16 Núm. 01 (2013); 1-7 1728-2977 1605-7724 reponame:Revistas - Universidad Nacional Mayor de San Marcos instname:Universidad Nacional Mayor de San Marcos instacron:UNMSM |
instname_str |
Universidad Nacional Mayor de San Marcos |
instacron_str |
UNMSM |
institution |
UNMSM |
reponame_str |
Revistas - Universidad Nacional Mayor de San Marcos |
collection |
Revistas - Universidad Nacional Mayor de San Marcos |
repository.name.fl_str_mv |
|
repository.mail.fl_str_mv |
|
_version_ |
1795238318906015744 |
score |
13.7211075 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).