The impact of 5S on Microbiological Air Quality of an agrobiological products quality laboratory

Descripción del Articulo

Microbiological air quality (MAQ) was monitored in the agrobiological products quality laboratory before and after the application of the "5S" methodology. The results were obtained through the agar-plate sedimentation method, carried out via biweekly sampling from April to June and from S...

Descripción completa

Detalles Bibliográficos
Autores: Huánuco, Lucía, Rosales López, Pedro Pablo
Formato: artículo
Fecha de Publicación:2018
Institución:Universidad Nacional Mayor de San Marcos
Repositorio:Revistas - Universidad Nacional Mayor de San Marcos
Lenguaje:español
OAI Identifier:oai:ojs.csi.unmsm:article/15599
Enlace del recurso:https://revistasinvestigacion.unmsm.edu.pe/index.php/idata/article/view/15599
Nivel de acceso:acceso abierto
Materia:5S
microbiological air quality
CFU
laboratory
Calidad microbiológica del aire
UFC
laboratorio
Descripción
Sumario:Microbiological air quality (MAQ) was monitored in the agrobiological products quality laboratory before and after the application of the "5S" methodology. The results were obtained through the agar-plate sedimentation method, carried out via biweekly sampling from April to June and from September to November of 2017, keeping temperature and relative humidity parameters constant (23 + 2 ° C and 62 + 3%). The initial level of 5S achieved only 43% of compliance, considered as "Below average", obtaining in this instance MAQ sampling distributed among fungi of 25 CFU/plate (50%), followed by bacteria at 16 CFU/plate (33%) and yeast at 8 CFU/plate (17%). In contrast, after carrying out 5S implementation, a result of 91% or "Excellent" level was obtained, which had fungal counts of 14 CFU/plate and 1 CFU/plate for the case of bacteria and yeasts. That is to say, the total microbial load decreased 68% between both conditions. By means of Student’s T test for means of related samples, significant differences in Microbiological Air Quality before and after 5S implementation at the laboratory studied were confirmed.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).