Characterization of X-ray beams by Attenuation Method for Calibration of Personal Dosimeters
Descripción del Articulo
The choice of the attenuation method to characterize the X rays beams used in the calibration of personal dosemeters at the Calibraion and Dosimetry laboratiry of the Peruvian Institute of Nuclear Energy (IPEN). Voltages applied to the X ray tube and the addition of filters have been made according...
Autores: | , , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 1999 |
Institución: | Universidad Nacional Mayor de San Marcos |
Repositorio: | Revistas - Universidad Nacional Mayor de San Marcos |
Lenguaje: | español |
OAI Identifier: | oai:ojs.csi.unmsm:article/8599 |
Enlace del recurso: | https://revistasinvestigacion.unmsm.edu.pe/index.php/fisica/article/view/8599 |
Nivel de acceso: | acceso abierto |
Materia: | X ray attenuation spectra dosimetry radioprotection rayos X atenuación espectros dosímetría radioprotección |
id |
REVUNMSM_34348670e97c0938505dd041dabc57e2 |
---|---|
oai_identifier_str |
oai:ojs.csi.unmsm:article/8599 |
network_acronym_str |
REVUNMSM |
network_name_str |
Revistas - Universidad Nacional Mayor de San Marcos |
repository_id_str |
|
spelling |
Characterization of X-ray beams by Attenuation Method for Calibration of Personal DosimetersCaracterización de Haces de Rayos X por el Método de Atenuación para la Calibración de Dosímetros PersonalesBenavente, T.Márquez, J.Santa Cruz, J.X rayattenuationspectradosimetryradioprotectionrayos XatenuaciónespectrosdosímetríaradioprotecciónThe choice of the attenuation method to characterize the X rays beams used in the calibration of personal dosemeters at the Calibraion and Dosimetry laboratiry of the Peruvian Institute of Nuclear Energy (IPEN). Voltages applied to the X ray tube and the addition of filters have been made according to the publication ANSI No.13. Half value layer, homogeneity coefficient were found with respect to values published in ANSI No.13. Also spectral distributions and their resolutions were determined. Relative differences of 16 and 9% respectively were found in comparison with values calculated by the Montecarlo's Method.En el Laboratorio de Calibraciones y Dosimetría del IPEN se ha empleado el méodo de atenuación para caracterizar los haces de rayos X utilizados en la calibración de dosímetros personales. Los volatjes aplicados al tubo de rayos X y las filttraciones adicionales empleadas son sugeridos en el ANSI Nro. 13. A partir de los datos de atenuación se determinó la capa semirreductora, el coeficiente de homogeneidad y la energía media, encontrándose en promedio diferencias relativas de 3, 40 y 4% con respecto a los valores de ANSI Nro. 13. También se determinaron las distribuciones espectrales y sus resoluaciones; halándose diferencias relativas de 16 y 9% respectivamente, en comparación con los calculados por la técnica de Montecarlo.Universidad Nacional Mayor de San Marcos1999-04-02info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistasinvestigacion.unmsm.edu.pe/index.php/fisica/article/view/859910.15381/rif.v1i02.8599Revista de Investigación de Física; Vol. 1 No. 02 (1998); 52-55Revista de Investigación de Física; Vol. 1 Núm. 02 (1998); 52-551728-29771605-7724reponame:Revistas - Universidad Nacional Mayor de San Marcosinstname:Universidad Nacional Mayor de San Marcosinstacron:UNMSMspahttps://revistasinvestigacion.unmsm.edu.pe/index.php/fisica/article/view/8599/7445Derechos de autor 1999 T. Benavente, J. Márquez, J. Santa Cruzhttps://creativecommons.org/licenses/by-nc-sa/4.0info:eu-repo/semantics/openAccessoai:ojs.csi.unmsm:article/85992020-07-30T18:37:00Z |
dc.title.none.fl_str_mv |
Characterization of X-ray beams by Attenuation Method for Calibration of Personal Dosimeters Caracterización de Haces de Rayos X por el Método de Atenuación para la Calibración de Dosímetros Personales |
title |
Characterization of X-ray beams by Attenuation Method for Calibration of Personal Dosimeters |
spellingShingle |
Characterization of X-ray beams by Attenuation Method for Calibration of Personal Dosimeters Benavente, T. X ray attenuation spectra dosimetry radioprotection rayos X atenuación espectros dosímetría radioprotección |
title_short |
Characterization of X-ray beams by Attenuation Method for Calibration of Personal Dosimeters |
title_full |
Characterization of X-ray beams by Attenuation Method for Calibration of Personal Dosimeters |
title_fullStr |
Characterization of X-ray beams by Attenuation Method for Calibration of Personal Dosimeters |
title_full_unstemmed |
Characterization of X-ray beams by Attenuation Method for Calibration of Personal Dosimeters |
title_sort |
Characterization of X-ray beams by Attenuation Method for Calibration of Personal Dosimeters |
dc.creator.none.fl_str_mv |
Benavente, T. Márquez, J. Santa Cruz, J. |
author |
Benavente, T. |
author_facet |
Benavente, T. Márquez, J. Santa Cruz, J. |
author_role |
author |
author2 |
Márquez, J. Santa Cruz, J. |
author2_role |
author author |
dc.subject.none.fl_str_mv |
X ray attenuation spectra dosimetry radioprotection rayos X atenuación espectros dosímetría radioprotección |
topic |
X ray attenuation spectra dosimetry radioprotection rayos X atenuación espectros dosímetría radioprotección |
description |
The choice of the attenuation method to characterize the X rays beams used in the calibration of personal dosemeters at the Calibraion and Dosimetry laboratiry of the Peruvian Institute of Nuclear Energy (IPEN). Voltages applied to the X ray tube and the addition of filters have been made according to the publication ANSI No.13. Half value layer, homogeneity coefficient were found with respect to values published in ANSI No.13. Also spectral distributions and their resolutions were determined. Relative differences of 16 and 9% respectively were found in comparison with values calculated by the Montecarlo's Method. |
publishDate |
1999 |
dc.date.none.fl_str_mv |
1999-04-02 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
https://revistasinvestigacion.unmsm.edu.pe/index.php/fisica/article/view/8599 10.15381/rif.v1i02.8599 |
url |
https://revistasinvestigacion.unmsm.edu.pe/index.php/fisica/article/view/8599 |
identifier_str_mv |
10.15381/rif.v1i02.8599 |
dc.language.none.fl_str_mv |
spa |
language |
spa |
dc.relation.none.fl_str_mv |
https://revistasinvestigacion.unmsm.edu.pe/index.php/fisica/article/view/8599/7445 |
dc.rights.none.fl_str_mv |
Derechos de autor 1999 T. Benavente, J. Márquez, J. Santa Cruz https://creativecommons.org/licenses/by-nc-sa/4.0 info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Derechos de autor 1999 T. Benavente, J. Márquez, J. Santa Cruz https://creativecommons.org/licenses/by-nc-sa/4.0 |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidad Nacional Mayor de San Marcos |
publisher.none.fl_str_mv |
Universidad Nacional Mayor de San Marcos |
dc.source.none.fl_str_mv |
Revista de Investigación de Física; Vol. 1 No. 02 (1998); 52-55 Revista de Investigación de Física; Vol. 1 Núm. 02 (1998); 52-55 1728-2977 1605-7724 reponame:Revistas - Universidad Nacional Mayor de San Marcos instname:Universidad Nacional Mayor de San Marcos instacron:UNMSM |
instname_str |
Universidad Nacional Mayor de San Marcos |
instacron_str |
UNMSM |
institution |
UNMSM |
reponame_str |
Revistas - Universidad Nacional Mayor de San Marcos |
collection |
Revistas - Universidad Nacional Mayor de San Marcos |
repository.name.fl_str_mv |
|
repository.mail.fl_str_mv |
|
_version_ |
1795238318175158272 |
score |
13.871978 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).