Shear strength of brick mortar interface for masonry in Lima city

Descripción del Articulo

Masonry structures constitute a large proportion of the building inventory in Lima and in most cities in Peru, mainly because of their benefits in terms of low cost, good mechanical properties and easily worked. It was observed in the cyclic loading test of masonry walls carried out at CISMID that t...

Descripción completa

Detalles Bibliográficos
Autores: Lavado, Luis, Gallardo, Jorge
Formato: artículo
Fecha de Publicación:2019
Institución:Universidad Nacional de Ingeniería
Repositorio:Revistas - Universidad Nacional de Ingeniería
Lenguaje:español
OAI Identifier:oai:oai:revistas.uni.edu.pe:article/707
Enlace del recurso:https://revistas.uni.edu.pe/index.php/tecnia/article/view/707
Nivel de acceso:acceso abierto
Materia:Mansory
cortante directo
Ladrillo hecho a mano
Interface
Direct Shear
Handmade brick
id REVUNI_f1fd7ca4a8a919422452a2e1aac5c95f
oai_identifier_str oai:oai:revistas.uni.edu.pe:article/707
network_acronym_str REVUNI
network_name_str Revistas - Universidad Nacional de Ingeniería
repository_id_str
spelling Shear strength of brick mortar interface for masonry in Lima cityResistencia al corte de la interfaz de mortero de ladrillo para mampostería en la ciudad de LimaLavado, LuisGallardo, JorgeMansorycortante directoLadrillo hecho a manoInterfaceMansoryDirect ShearHandmade brickInterfaceMasonry structures constitute a large proportion of the building inventory in Lima and in most cities in Peru, mainly because of their benefits in terms of low cost, good mechanical properties and easily worked. It was observed in the cyclic loading test of masonry walls carried out at CISMID that the modes of failures can be mainly generated by shear forces. Based on the previous information, it is known that diagonal cracking and slip of the mortar-brick joints are the dominant failure mechanisms of confined masonry walls.  In order to determine the mechanical behavior in the mortar-brick joint, an experimental program was carried out, by using industrial and handmade bricks. The test specimens were specifically designed to transmit pure shear along the bed joints under certain constant levels of compressive stress normal to the bed joint. The results of experimental shear tests are presented and discussed. It is then found a consistency between the behavior of masonry joints under shear with the Mohr Coulomb criterion. The shear failure capacity was influenced by the brick type, pre-compression load level and mortar type. It is also noticed in this experimental study that the pre-compressive stress normal to the bed joints significantly increase the shear strength of the mortar-brick joint.Las estructuras de mampostería constituyen una gran proporción del inventario de edificaciones en Lima y en la mayoría de las ciudades del Perú, principalmente por sus beneficios en términos de bajo costo, buenas propiedades mecánicas y facilidad de trabajo. Se observó en el ensayo de carga cíclica de muros de mampostería realizado en el CISMID que los modos de falla pueden ser generados principalmente por fuerzas cortantes. Con base en la información anterior, se sabe que el agrietamiento diagonal y el deslizamiento de las juntas mortero-ladrillo son los mecanismos de falla dominantes de los muros de mampostería confinada. Para determinar el comportamiento mecánico en la unión mortero-ladrillo se realizó un programa experimental, utilizando ladrillos industriales y artesanales. Los especímenes de prueba fueron diseñados específicamente para transmitir cortante puro a lo largo de las juntas del lecho bajo ciertos niveles constantes de tensión de compresión normales a la junta del lecho. Se presentan y discuten los resultados de las pruebas experimentales de corte. Se encuentra entonces una consistencia entre el comportamiento de las juntas de mampostería bajo cortante con el criterio de Mohr Coulomb. La capacidad de falla por cortante estuvo influenciada por el tipo de ladrillo, el nivel de carga de precompresión y el tipo de mortero. También se observa en este estudio experimental que la tensión precompresiva normal a las juntas del lecho aumenta significativamente la resistencia al corte de la junta mortero-ladrillo.  Universidad Nacional de Ingeniería2019-08-07info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionTECNIA Special Issue on Earthquake Engineeringapplication/pdfaudio/mpeghttps://revistas.uni.edu.pe/index.php/tecnia/article/view/70710.21754/tecnia.v29i2.707TECNIA; Vol. 29 No. 2 (2019): Earthquake Engineering; 59.64TECNIA; Vol. 29 Núm. 2 (2019): Ingeniería Sísmica; 59.642309-04130375-7765reponame:Revistas - Universidad Nacional de Ingenieríainstname:Universidad Nacional de Ingenieríainstacron:UNIspahttps://revistas.uni.edu.pe/index.php/tecnia/article/view/707/1109https://revistas.uni.edu.pe/index.php/tecnia/article/view/707/1127Derechos de autor 2019 TECNIAhttp://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessoai:oai:revistas.uni.edu.pe:article/7072023-12-11T03:28:44Z
dc.title.none.fl_str_mv Shear strength of brick mortar interface for masonry in Lima city
Resistencia al corte de la interfaz de mortero de ladrillo para mampostería en la ciudad de Lima
title Shear strength of brick mortar interface for masonry in Lima city
spellingShingle Shear strength of brick mortar interface for masonry in Lima city
Lavado, Luis
Mansory
cortante directo
Ladrillo hecho a mano
Interface
Mansory
Direct Shear
Handmade brick
Interface
title_short Shear strength of brick mortar interface for masonry in Lima city
title_full Shear strength of brick mortar interface for masonry in Lima city
title_fullStr Shear strength of brick mortar interface for masonry in Lima city
title_full_unstemmed Shear strength of brick mortar interface for masonry in Lima city
title_sort Shear strength of brick mortar interface for masonry in Lima city
dc.creator.none.fl_str_mv Lavado, Luis
Gallardo, Jorge
author Lavado, Luis
author_facet Lavado, Luis
Gallardo, Jorge
author_role author
author2 Gallardo, Jorge
author2_role author
dc.subject.none.fl_str_mv Mansory
cortante directo
Ladrillo hecho a mano
Interface
Mansory
Direct Shear
Handmade brick
Interface
topic Mansory
cortante directo
Ladrillo hecho a mano
Interface
Mansory
Direct Shear
Handmade brick
Interface
description Masonry structures constitute a large proportion of the building inventory in Lima and in most cities in Peru, mainly because of their benefits in terms of low cost, good mechanical properties and easily worked. It was observed in the cyclic loading test of masonry walls carried out at CISMID that the modes of failures can be mainly generated by shear forces. Based on the previous information, it is known that diagonal cracking and slip of the mortar-brick joints are the dominant failure mechanisms of confined masonry walls.  In order to determine the mechanical behavior in the mortar-brick joint, an experimental program was carried out, by using industrial and handmade bricks. The test specimens were specifically designed to transmit pure shear along the bed joints under certain constant levels of compressive stress normal to the bed joint. The results of experimental shear tests are presented and discussed. It is then found a consistency between the behavior of masonry joints under shear with the Mohr Coulomb criterion. The shear failure capacity was influenced by the brick type, pre-compression load level and mortar type. It is also noticed in this experimental study that the pre-compressive stress normal to the bed joints significantly increase the shear strength of the mortar-brick joint.
publishDate 2019
dc.date.none.fl_str_mv 2019-08-07
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
TECNIA Special Issue on Earthquake Engineering
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://revistas.uni.edu.pe/index.php/tecnia/article/view/707
10.21754/tecnia.v29i2.707
url https://revistas.uni.edu.pe/index.php/tecnia/article/view/707
identifier_str_mv 10.21754/tecnia.v29i2.707
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv https://revistas.uni.edu.pe/index.php/tecnia/article/view/707/1109
https://revistas.uni.edu.pe/index.php/tecnia/article/view/707/1127
dc.rights.none.fl_str_mv Derechos de autor 2019 TECNIA
http://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Derechos de autor 2019 TECNIA
http://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
audio/mpeg
dc.publisher.none.fl_str_mv Universidad Nacional de Ingeniería
publisher.none.fl_str_mv Universidad Nacional de Ingeniería
dc.source.none.fl_str_mv TECNIA; Vol. 29 No. 2 (2019): Earthquake Engineering; 59.64
TECNIA; Vol. 29 Núm. 2 (2019): Ingeniería Sísmica; 59.64
2309-0413
0375-7765
reponame:Revistas - Universidad Nacional de Ingeniería
instname:Universidad Nacional de Ingeniería
instacron:UNI
instname_str Universidad Nacional de Ingeniería
instacron_str UNI
institution UNI
reponame_str Revistas - Universidad Nacional de Ingeniería
collection Revistas - Universidad Nacional de Ingeniería
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1833562779052670976
score 13.888049
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).