Active power filter under differents loads
Descripción del Articulo
Active filtering of electric power has now become a nature technology for harmonic and reactive power compensation. This paper deals about study and simulation of an Active Power Filter (APF) it Works with a four different single phase non linear loads, also simulations results of practical cases ar...
Autores: | , , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2005 |
Institución: | Universidad Nacional de Ingeniería |
Repositorio: | Revistas - Universidad Nacional de Ingeniería |
Lenguaje: | español |
OAI Identifier: | oai:oai:revistas.uni.edu.pe:article/421 |
Enlace del recurso: | https://revistas.uni.edu.pe/index.php/tecnia/article/view/421 |
Nivel de acceso: | acceso abierto |
Materia: | Filtro activo de potencia Armónicos Cargas no lineales Active power filter Harmonics Non linear loads |
id |
REVUNI_e7252295b8b08ed7292f116b178c68f6 |
---|---|
oai_identifier_str |
oai:oai:revistas.uni.edu.pe:article/421 |
network_acronym_str |
REVUNI |
network_name_str |
Revistas - Universidad Nacional de Ingeniería |
repository_id_str |
|
spelling |
Active power filter under differents loadsFiltro activo de potencia bajo diferentes tipos de cargaNúñez Zuñiga, TeresaSoto Lock, AlbertoMoreno Martinez, RodolfoFiltro activo de potenciaArmónicosCargas no linealesActive power filterHarmonicsNon linear loadsActive filtering of electric power has now become a nature technology for harmonic and reactive power compensation. This paper deals about study and simulation of an Active Power Filter (APF) it Works with a four different single phase non linear loads, also simulations results of practical cases are included.Debido al significativo desarrollo alcanzado por la electrónica de potencia se ha producido la proliferación de cargas no lineales como los rectificadores de gran potencia, los que son responsables por el deterioro de la calidad de la onda corriente. Este problema se traduce en la inyección de armónicos de corriente por parte de las cargas no lineales a la red y que se ha convertido en un problema muy serio. En el presente artículo se estudia y simula un Filtro Activo de Potencia (FAP) shunt, para la compensación de diferentes cargas monofásicas no lineales, las que suelen encontrarse en la industria y eliminar el efecto nocivo de la inyección de armónicos de corriente a la red.Universidad Nacional de Ingeniería2005-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionArtículo evaluado por paresapplication/pdfhttps://revistas.uni.edu.pe/index.php/tecnia/article/view/42110.21754/tecnia.v9i1.421TECNIA; Vol. 9 No. 1 (1999); 13-24TECNIA; Vol. 9 Núm. 1 (1999); 13-242309-04130375-7765reponame:Revistas - Universidad Nacional de Ingenieríainstname:Universidad Nacional de Ingenieríainstacron:UNIspahttps://revistas.uni.edu.pe/index.php/tecnia/article/view/421/331Derechos de autor 2005 TECNIAhttp://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessoai:oai:revistas.uni.edu.pe:article/4212023-12-01T15:56:21Z |
dc.title.none.fl_str_mv |
Active power filter under differents loads Filtro activo de potencia bajo diferentes tipos de carga |
title |
Active power filter under differents loads |
spellingShingle |
Active power filter under differents loads Núñez Zuñiga, Teresa Filtro activo de potencia Armónicos Cargas no lineales Active power filter Harmonics Non linear loads |
title_short |
Active power filter under differents loads |
title_full |
Active power filter under differents loads |
title_fullStr |
Active power filter under differents loads |
title_full_unstemmed |
Active power filter under differents loads |
title_sort |
Active power filter under differents loads |
dc.creator.none.fl_str_mv |
Núñez Zuñiga, Teresa Soto Lock, Alberto Moreno Martinez, Rodolfo |
author |
Núñez Zuñiga, Teresa |
author_facet |
Núñez Zuñiga, Teresa Soto Lock, Alberto Moreno Martinez, Rodolfo |
author_role |
author |
author2 |
Soto Lock, Alberto Moreno Martinez, Rodolfo |
author2_role |
author author |
dc.subject.none.fl_str_mv |
Filtro activo de potencia Armónicos Cargas no lineales Active power filter Harmonics Non linear loads |
topic |
Filtro activo de potencia Armónicos Cargas no lineales Active power filter Harmonics Non linear loads |
description |
Active filtering of electric power has now become a nature technology for harmonic and reactive power compensation. This paper deals about study and simulation of an Active Power Filter (APF) it Works with a four different single phase non linear loads, also simulations results of practical cases are included. |
publishDate |
2005 |
dc.date.none.fl_str_mv |
2005-12-01 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Artículo evaluado por pares |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
https://revistas.uni.edu.pe/index.php/tecnia/article/view/421 10.21754/tecnia.v9i1.421 |
url |
https://revistas.uni.edu.pe/index.php/tecnia/article/view/421 |
identifier_str_mv |
10.21754/tecnia.v9i1.421 |
dc.language.none.fl_str_mv |
spa |
language |
spa |
dc.relation.none.fl_str_mv |
https://revistas.uni.edu.pe/index.php/tecnia/article/view/421/331 |
dc.rights.none.fl_str_mv |
Derechos de autor 2005 TECNIA http://creativecommons.org/licenses/by/4.0 info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Derechos de autor 2005 TECNIA http://creativecommons.org/licenses/by/4.0 |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidad Nacional de Ingeniería |
publisher.none.fl_str_mv |
Universidad Nacional de Ingeniería |
dc.source.none.fl_str_mv |
TECNIA; Vol. 9 No. 1 (1999); 13-24 TECNIA; Vol. 9 Núm. 1 (1999); 13-24 2309-0413 0375-7765 reponame:Revistas - Universidad Nacional de Ingeniería instname:Universidad Nacional de Ingeniería instacron:UNI |
instname_str |
Universidad Nacional de Ingeniería |
instacron_str |
UNI |
institution |
UNI |
reponame_str |
Revistas - Universidad Nacional de Ingeniería |
collection |
Revistas - Universidad Nacional de Ingeniería |
repository.name.fl_str_mv |
|
repository.mail.fl_str_mv |
|
_version_ |
1833562777428426752 |
score |
13.947759 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).