Behavior of a scaled‐down scrubber for the removal of H2S from the gases of an upflow anaerobic sludge blanket reactor
Descripción del Articulo
The present work reports the simulation of a wet scrubber coupled to an UASB reactor. The scrubber consisted of baffles, packed bed of sponge material, an acrylic tube and all the connections necessary to bring the H2S‐ladden biogas. The purpose of the equipment is to eliminate some of the gases com...
Autores: | , , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2017 |
Institución: | Universidad Nacional de Ingeniería |
Repositorio: | Revistas - Universidad Nacional de Ingeniería |
Lenguaje: | español |
OAI Identifier: | oai:oai:revistas.uni.edu.pe:article/130 |
Enlace del recurso: | https://revistas.uni.edu.pe/index.php/tecnia/article/view/130 |
Nivel de acceso: | acceso abierto |
Materia: | torre de lavado reactor UASB remoción de sulfuro de hidrógeno scrubber tower UASB reactor hydrogen sulfide removal |
id |
REVUNI_9f01be3cfcb3a6c77de24a8a30f426a9 |
---|---|
oai_identifier_str |
oai:oai:revistas.uni.edu.pe:article/130 |
network_acronym_str |
REVUNI |
network_name_str |
Revistas - Universidad Nacional de Ingeniería |
repository_id_str |
|
spelling |
Behavior of a scaled‐down scrubber for the removal of H2S from the gases of an upflow anaerobic sludge blanket reactorComportamiento de torre de lavado a nivel de escala para la remoción de H2S de un reactor anaerobico de flujo ascendenteAcaro, JoséQuispe, JeannieSalas, Malitorre de lavadoreactor UASBremoción de sulfuro de hidrógenoscrubber towerUASB reactorhydrogen sulfide removalThe present work reports the simulation of a wet scrubber coupled to an UASB reactor. The scrubber consisted of baffles, packed bed of sponge material, an acrylic tube and all the connections necessary to bring the H2S‐ladden biogas. The purpose of the equipment is to eliminate some of the gases coming out of the reactor, through their oxidation by the dissolved oxygen provided by the microalgae present in the water from the tertiary lagoon. Hydrogen sulfide is a foul‐ smelling and toxic gas which can cause death at high concentrations, and can also cause damage to the structures with which it comes into contact. The scrubber was installed on the site of CITRAR‐UNI and the behavior of the equipment was monitored during three weeks by following the temperature, pH and the concentrations of sulfates and dissolved oxygen. The results have shown that the scrubber was effectively an oxidizing environment which was removing H2S, since the dissolved oxygen was actually consumed gradually. It was also observed that the sulfate concentration was increasing, indicating a consumption of H2S, which was also confirmed by a reduction in the odor of the gas. Nuestro equipo en esta oportunidad hizo una simulación de una torre de lavado, la cual la aplicamos en el reactor UASB, a manera de escala construimos una torre de lavado compuesta por difusores, una cama de sólidos hecha de material de esponja, un tubo de acrílico y todas las conexiones que conducen el biogás con H2S. Los componentes a eliminar y/o remover fueron los gases que salen del reactor, en especial del H2S (gas odorífero y toxico que a grandes concentraciones pude llevar a la muerte y como resultado de sus reacciones con el ambiente puede causar daños en las estructuras con la cual este en contacto) mediante la oxidación con el oxígeno disuelto que proveen las microalgas presentes en el agua de la laguna terciara utilizada. Esta torre de lavado la montamos en las instalaciones de CITRAR‐UNI con el permiso del operador y vimos el comportamiento que tiene esta torre, mediante los monitoreos de oxígeno disuelto, temperatura, pH y sulfatos que realizamos durante tres semanas de monitoreo. Como resultados obtuvimos que la torre de lavado sí oxidaba y removía la contracción de H2S, ya que cuando pasaba el tiempo se consumía el oxígeno disuelto, además de esto también en el monitoreo de sulfatos pudimos observar un aumento de este parámetro es decir la torre si estaba consumiendo en H2S, y por esta razón también disminuyo el olor fétido que produce este gas. Universidad Nacional de Ingeniería2017-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionArtículo evaluado por paresapplication/pdfaudio/mpegtext/htmlhttps://revistas.uni.edu.pe/index.php/tecnia/article/view/13010.21754/tecnia.v27i1.130TECNIA; Vol. 27 No. 1 (2017); 85-90TECNIA; Vol. 27 Núm. 1 (2017); 85-902309-04130375-7765reponame:Revistas - Universidad Nacional de Ingenieríainstname:Universidad Nacional de Ingenieríainstacron:UNIspahttps://revistas.uni.edu.pe/index.php/tecnia/article/view/130/94https://revistas.uni.edu.pe/index.php/tecnia/article/view/130/518https://revistas.uni.edu.pe/index.php/tecnia/article/view/130/557Derechos de autor 2017 TECNIAhttp://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessoai:oai:revistas.uni.edu.pe:article/1302023-12-06T21:07:58Z |
dc.title.none.fl_str_mv |
Behavior of a scaled‐down scrubber for the removal of H2S from the gases of an upflow anaerobic sludge blanket reactor Comportamiento de torre de lavado a nivel de escala para la remoción de H2S de un reactor anaerobico de flujo ascendente |
title |
Behavior of a scaled‐down scrubber for the removal of H2S from the gases of an upflow anaerobic sludge blanket reactor |
spellingShingle |
Behavior of a scaled‐down scrubber for the removal of H2S from the gases of an upflow anaerobic sludge blanket reactor Acaro, José torre de lavado reactor UASB remoción de sulfuro de hidrógeno scrubber tower UASB reactor hydrogen sulfide removal |
title_short |
Behavior of a scaled‐down scrubber for the removal of H2S from the gases of an upflow anaerobic sludge blanket reactor |
title_full |
Behavior of a scaled‐down scrubber for the removal of H2S from the gases of an upflow anaerobic sludge blanket reactor |
title_fullStr |
Behavior of a scaled‐down scrubber for the removal of H2S from the gases of an upflow anaerobic sludge blanket reactor |
title_full_unstemmed |
Behavior of a scaled‐down scrubber for the removal of H2S from the gases of an upflow anaerobic sludge blanket reactor |
title_sort |
Behavior of a scaled‐down scrubber for the removal of H2S from the gases of an upflow anaerobic sludge blanket reactor |
dc.creator.none.fl_str_mv |
Acaro, José Quispe, Jeannie Salas, Mali |
author |
Acaro, José |
author_facet |
Acaro, José Quispe, Jeannie Salas, Mali |
author_role |
author |
author2 |
Quispe, Jeannie Salas, Mali |
author2_role |
author author |
dc.subject.none.fl_str_mv |
torre de lavado reactor UASB remoción de sulfuro de hidrógeno scrubber tower UASB reactor hydrogen sulfide removal |
topic |
torre de lavado reactor UASB remoción de sulfuro de hidrógeno scrubber tower UASB reactor hydrogen sulfide removal |
description |
The present work reports the simulation of a wet scrubber coupled to an UASB reactor. The scrubber consisted of baffles, packed bed of sponge material, an acrylic tube and all the connections necessary to bring the H2S‐ladden biogas. The purpose of the equipment is to eliminate some of the gases coming out of the reactor, through their oxidation by the dissolved oxygen provided by the microalgae present in the water from the tertiary lagoon. Hydrogen sulfide is a foul‐ smelling and toxic gas which can cause death at high concentrations, and can also cause damage to the structures with which it comes into contact. The scrubber was installed on the site of CITRAR‐UNI and the behavior of the equipment was monitored during three weeks by following the temperature, pH and the concentrations of sulfates and dissolved oxygen. The results have shown that the scrubber was effectively an oxidizing environment which was removing H2S, since the dissolved oxygen was actually consumed gradually. It was also observed that the sulfate concentration was increasing, indicating a consumption of H2S, which was also confirmed by a reduction in the odor of the gas. |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017-06-01 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Artículo evaluado por pares |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
https://revistas.uni.edu.pe/index.php/tecnia/article/view/130 10.21754/tecnia.v27i1.130 |
url |
https://revistas.uni.edu.pe/index.php/tecnia/article/view/130 |
identifier_str_mv |
10.21754/tecnia.v27i1.130 |
dc.language.none.fl_str_mv |
spa |
language |
spa |
dc.relation.none.fl_str_mv |
https://revistas.uni.edu.pe/index.php/tecnia/article/view/130/94 https://revistas.uni.edu.pe/index.php/tecnia/article/view/130/518 https://revistas.uni.edu.pe/index.php/tecnia/article/view/130/557 |
dc.rights.none.fl_str_mv |
Derechos de autor 2017 TECNIA http://creativecommons.org/licenses/by/4.0 info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Derechos de autor 2017 TECNIA http://creativecommons.org/licenses/by/4.0 |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf audio/mpeg text/html |
dc.publisher.none.fl_str_mv |
Universidad Nacional de Ingeniería |
publisher.none.fl_str_mv |
Universidad Nacional de Ingeniería |
dc.source.none.fl_str_mv |
TECNIA; Vol. 27 No. 1 (2017); 85-90 TECNIA; Vol. 27 Núm. 1 (2017); 85-90 2309-0413 0375-7765 reponame:Revistas - Universidad Nacional de Ingeniería instname:Universidad Nacional de Ingeniería instacron:UNI |
instname_str |
Universidad Nacional de Ingeniería |
instacron_str |
UNI |
institution |
UNI |
reponame_str |
Revistas - Universidad Nacional de Ingeniería |
collection |
Revistas - Universidad Nacional de Ingeniería |
repository.name.fl_str_mv |
|
repository.mail.fl_str_mv |
|
_version_ |
1833562776077860864 |
score |
13.735319 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).