Determination of the size of small particles by light scattering
Descripción del Articulo
In this work, we describe the design and construction of a system to measure the angular light scattering distribution from small dielectric spheres suspended in water, using a laser as the light source. It also covers the development of an optical detection system to improve the signal‐to‐noise rat...
Autores: | , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2017 |
Institución: | Universidad Nacional de Ingeniería |
Repositorio: | Revistas - Universidad Nacional de Ingeniería |
Lenguaje: | español |
OAI Identifier: | oai:oai:revistas.uni.edu.pe:article/172 |
Enlace del recurso: | https://revistas.uni.edu.pe/index.php/tecnia/article/view/172 |
Nivel de acceso: | acceso abierto |
Materia: | scattering de luz micropartículas de látex teoría de Mie light scattering latex microparticles Mie theory |
id |
REVUNI_994cc6277ab3893e18900c6e6fb17c77 |
---|---|
oai_identifier_str |
oai:oai:revistas.uni.edu.pe:article/172 |
network_acronym_str |
REVUNI |
network_name_str |
Revistas - Universidad Nacional de Ingeniería |
repository_id_str |
|
spelling |
Determination of the size of small particles by light scatteringDeterminación del tamaño de partículas pequeñas por scattering de luzVelazco, AbnerGutarra, Abelscattering de luzmicropartículas de látexteoría de Mielight scatteringlatex microparticlesMie theoryIn this work, we describe the design and construction of a system to measure the angular light scattering distribution from small dielectric spheres suspended in water, using a laser as the light source. It also covers the development of an optical detection system to improve the signal‐to‐noise ratio. We report on the experimental measurements of light scattering from colloidal suspensions of latex spheres with nominal diameters of 0.49 and 1.03 µm and a coefficient of variation of 3%. Two lasers with different wavelengths (632.8 and 532.0 nm) were used to observe the variation of the angular scattering distribution. The experimental results were then compared with angular scattering distributions generated from Mie theory, in order to determine the particle size. We obtained diameters of 0.49 and 0.95 µm, with a relative accuracy of 6.1 and 5.3%, respectively. En este trabajo se describe el diseño y la construcción de un sistema para medir la distribución angular del scattering de luz de micro esferas dieléctricas suspendidas en agua, usando un láser como fuente de luz. El trabajo cubre el desarrollo de un sistema de detección óptico para mejorar la relación señal ruido. Reportamos medidas experimentales de scattering de luz de suspensiones coloidales de esferas de látex con diámetros nominales de 0,49 y 1,03 µm, y un coeficiente de variación de 3%. Se utilizaron dos láseres de diferentes longitudes de onda, 632,8 y 532,0 nm, para observar la variación de la distribución angular de scattering. Los resultados experimentales fueron comparados con distribuciones de scattering angular generadas por la teoría de Mie para determinar el tamaño de partícula. Los diámetros obtenidos fueron 0,49 y 0,95 µm con una incertidumbre relativa de 6,1 y 5,3%, respectivamente. Universidad Nacional de Ingeniería2017-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionArtículo evaluado por paresapplication/pdfaudio/mpegtext/htmlhttps://revistas.uni.edu.pe/index.php/tecnia/article/view/17210.21754/tecnia.v27i2.172TECNIA; Vol. 27 No. 2 (2017); 27-32TECNIA; Vol. 27 Núm. 2 (2017); 27-322309-04130375-7765reponame:Revistas - Universidad Nacional de Ingenieríainstname:Universidad Nacional de Ingenieríainstacron:UNIspahttps://revistas.uni.edu.pe/index.php/tecnia/article/view/172/46https://revistas.uni.edu.pe/index.php/tecnia/article/view/172/449https://revistas.uni.edu.pe/index.php/tecnia/article/view/172/538Derechos de autor 2017 TECNIAhttp://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessoai:oai:revistas.uni.edu.pe:article/1722023-12-06T21:17:47Z |
dc.title.none.fl_str_mv |
Determination of the size of small particles by light scattering Determinación del tamaño de partículas pequeñas por scattering de luz |
title |
Determination of the size of small particles by light scattering |
spellingShingle |
Determination of the size of small particles by light scattering Velazco, Abner scattering de luz micropartículas de látex teoría de Mie light scattering latex microparticles Mie theory |
title_short |
Determination of the size of small particles by light scattering |
title_full |
Determination of the size of small particles by light scattering |
title_fullStr |
Determination of the size of small particles by light scattering |
title_full_unstemmed |
Determination of the size of small particles by light scattering |
title_sort |
Determination of the size of small particles by light scattering |
dc.creator.none.fl_str_mv |
Velazco, Abner Gutarra, Abel |
author |
Velazco, Abner |
author_facet |
Velazco, Abner Gutarra, Abel |
author_role |
author |
author2 |
Gutarra, Abel |
author2_role |
author |
dc.subject.none.fl_str_mv |
scattering de luz micropartículas de látex teoría de Mie light scattering latex microparticles Mie theory |
topic |
scattering de luz micropartículas de látex teoría de Mie light scattering latex microparticles Mie theory |
description |
In this work, we describe the design and construction of a system to measure the angular light scattering distribution from small dielectric spheres suspended in water, using a laser as the light source. It also covers the development of an optical detection system to improve the signal‐to‐noise ratio. We report on the experimental measurements of light scattering from colloidal suspensions of latex spheres with nominal diameters of 0.49 and 1.03 µm and a coefficient of variation of 3%. Two lasers with different wavelengths (632.8 and 532.0 nm) were used to observe the variation of the angular scattering distribution. The experimental results were then compared with angular scattering distributions generated from Mie theory, in order to determine the particle size. We obtained diameters of 0.49 and 0.95 µm, with a relative accuracy of 6.1 and 5.3%, respectively. |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017-12-01 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Artículo evaluado por pares |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
https://revistas.uni.edu.pe/index.php/tecnia/article/view/172 10.21754/tecnia.v27i2.172 |
url |
https://revistas.uni.edu.pe/index.php/tecnia/article/view/172 |
identifier_str_mv |
10.21754/tecnia.v27i2.172 |
dc.language.none.fl_str_mv |
spa |
language |
spa |
dc.relation.none.fl_str_mv |
https://revistas.uni.edu.pe/index.php/tecnia/article/view/172/46 https://revistas.uni.edu.pe/index.php/tecnia/article/view/172/449 https://revistas.uni.edu.pe/index.php/tecnia/article/view/172/538 |
dc.rights.none.fl_str_mv |
Derechos de autor 2017 TECNIA http://creativecommons.org/licenses/by/4.0 info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Derechos de autor 2017 TECNIA http://creativecommons.org/licenses/by/4.0 |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf audio/mpeg text/html |
dc.publisher.none.fl_str_mv |
Universidad Nacional de Ingeniería |
publisher.none.fl_str_mv |
Universidad Nacional de Ingeniería |
dc.source.none.fl_str_mv |
TECNIA; Vol. 27 No. 2 (2017); 27-32 TECNIA; Vol. 27 Núm. 2 (2017); 27-32 2309-0413 0375-7765 reponame:Revistas - Universidad Nacional de Ingeniería instname:Universidad Nacional de Ingeniería instacron:UNI |
instname_str |
Universidad Nacional de Ingeniería |
instacron_str |
UNI |
institution |
UNI |
reponame_str |
Revistas - Universidad Nacional de Ingeniería |
collection |
Revistas - Universidad Nacional de Ingeniería |
repository.name.fl_str_mv |
|
repository.mail.fl_str_mv |
|
_version_ |
1833562776127143936 |
score |
13.87115 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).