Efficiency of energy dissipators in the seismic response of buildings

Descripción del Articulo

This paper aims to study the efficiency of energy dissipators, both fluid viscous and hysteretic, to improve the seismic responses of buildings. To quantify the ability of energy dissipators to reduce seismic responses, a series of time history analyzes were carried out on simplified models of build...

Descripción completa

Detalles Bibliográficos
Autores: Saldaña Vasquez, Keyvin Yuliño, Scaletti Farina, Hugo Victor Luis
Formato: artículo
Fecha de Publicación:2022
Institución:Universidad Nacional de Ingeniería
Repositorio:Revistas - Universidad Nacional de Ingeniería
Lenguaje:español
OAI Identifier:oai:oai:revistas.uni.edu.pe:article/1379
Enlace del recurso:https://revistas.uni.edu.pe/index.php/tecnia/article/view/1379
Nivel de acceso:acceso abierto
Materia:Energy dissipators
Fluid viscous dampers
Hysteretic dampers
Seismic protection systems
Hysteretic dampers dimensioning
Descripción
Sumario:This paper aims to study the efficiency of energy dissipators, both fluid viscous and hysteretic, to improve the seismic responses of buildings. To quantify the ability of energy dissipators to reduce seismic responses, a series of time history analyzes were carried out on simplified models of buildings. Said simplified models consist of masses and springs with linear and elastic behavior whose properties are obtained from a shear beam model, joined by link elements with non-linear behavior to simulate energy dissipators. The main study parameters that were considered are the fundamental period of the structure without seismic control devices and the objective reduction factor. Likewise, a procedure is proposed for the dimensioning of the hysteretic dampers that will be incorporated into a building. On the other hand, the main building of the Lima airport was used as a case study, for which two alternatives are proposed, each one with a different type of energy dissipator, but both designed to have similar performance. Finally, the reductions obtained by both the simplified models and three-dimensional models are compared. It is concluded that the simplified models allow a fast and acceptable prediction of the levels of reduction of the seismic response in buildings that incorporate energy dissipators.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).