Efficiency of energy dissipators in the seismic response of buildings
Descripción del Articulo
This paper aims to study the efficiency of energy dissipators, both fluid viscous and hysteretic, to improve the seismic responses of buildings. To quantify the ability of energy dissipators to reduce seismic responses, a series of time history analyzes were carried out on simplified models of build...
Autores: | , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2022 |
Institución: | Universidad Nacional de Ingeniería |
Repositorio: | Revistas - Universidad Nacional de Ingeniería |
Lenguaje: | español |
OAI Identifier: | oai:oai:revistas.uni.edu.pe:article/1379 |
Enlace del recurso: | https://revistas.uni.edu.pe/index.php/tecnia/article/view/1379 |
Nivel de acceso: | acceso abierto |
Materia: | Energy dissipators Fluid viscous dampers Hysteretic dampers Seismic protection systems Hysteretic dampers dimensioning |
Sumario: | This paper aims to study the efficiency of energy dissipators, both fluid viscous and hysteretic, to improve the seismic responses of buildings. To quantify the ability of energy dissipators to reduce seismic responses, a series of time history analyzes were carried out on simplified models of buildings. Said simplified models consist of masses and springs with linear and elastic behavior whose properties are obtained from a shear beam model, joined by link elements with non-linear behavior to simulate energy dissipators. The main study parameters that were considered are the fundamental period of the structure without seismic control devices and the objective reduction factor. Likewise, a procedure is proposed for the dimensioning of the hysteretic dampers that will be incorporated into a building. On the other hand, the main building of the Lima airport was used as a case study, for which two alternatives are proposed, each one with a different type of energy dissipator, but both designed to have similar performance. Finally, the reductions obtained by both the simplified models and three-dimensional models are compared. It is concluded that the simplified models allow a fast and acceptable prediction of the levels of reduction of the seismic response in buildings that incorporate energy dissipators. |
---|
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).