C,B,R, for Sandy and Silt-Clay Subgrades
Descripción del Articulo
Currently in Peru, the design of pavement structures generally considers support capacity values of sandy and silt-clayey subgrades determined fromof laboratory tests CBR- ASTM DI883.The methodology used may not be adequately applied when the C.B.R. value is assumed.of the subgrade related to the...
Autores: | , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2001 |
Institución: | Universidad Nacional de Ingeniería |
Repositorio: | Revistas - Universidad Nacional de Ingeniería |
Lenguaje: | español |
OAI Identifier: | oai:oai:revistas.uni.edu.pe:article/522 |
Enlace del recurso: | https://revistas.uni.edu.pe/index.php/tecnia/article/view/522 |
Nivel de acceso: | acceso abierto |
Sumario: | Currently in Peru, the design of pavement structures generally considers support capacity values of sandy and silt-clayey subgrades determined fromof laboratory tests CBR- ASTM DI883.The methodology used may not be adequately applied when the C.B.R. value is assumed.of the subgrade related to the dry density equivalent to 95% 6 100% of the Maximum Dry Density - MDS of the Modified Proctor test.The humidity and natural dry density of silt-clay soils have an important influence on the determination of the C.B.R. as has been confirmed in tests on unaltered and compacted samplesComparisons of C.B.R. values were made. obtained from unaltered and compacted samples considering 95% and 100% of the MDS of the Modified Proctor test. Likewise, values of elastic moduli were compared, using an extension of elastic theory.The results indicate that the values of C.B.R. and elastic moduli obtained in samplesunaltered are significantly lower than those determined in compacted samples.The engineering practice for determining the C.B.R. of the subgrade based on unaltered samples is almost not used in Peru, due to this, premature failures of pavements occur due to under-sizing in the design. |
---|
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).