C,B,R, for Sandy and Silt-Clay Subgrades

Descripción del Articulo

Currently in Peru, the design of pavement structures generally considers support capacity values ​​of sandy and silt-clayey subgrades determined fromof laboratory tests CBR- ASTM DI883.The methodology used may not be adequately applied when the C.B.R. value is assumed.of the subgrade related to the...

Descripción completa

Detalles Bibliográficos
Autores: Ordoñez Huaman, Abel, Minaya González, Silene
Formato: artículo
Fecha de Publicación:2001
Institución:Universidad Nacional de Ingeniería
Repositorio:Revistas - Universidad Nacional de Ingeniería
Lenguaje:español
OAI Identifier:oai:oai:revistas.uni.edu.pe:article/522
Enlace del recurso:https://revistas.uni.edu.pe/index.php/tecnia/article/view/522
Nivel de acceso:acceso abierto
id REVUNI_1cd32bc96f955fc8173dc9e29626748f
oai_identifier_str oai:oai:revistas.uni.edu.pe:article/522
network_acronym_str REVUNI
network_name_str Revistas - Universidad Nacional de Ingeniería
repository_id_str
spelling C,B,R, for Sandy and Silt-Clay SubgradesC,B,R, de Subrasantes Arenosas y Limo-ArcillosasOrdoñez Huaman, AbelMinaya González, SileneCurrently in Peru, the design of pavement structures generally considers support capacity values ​​of sandy and silt-clayey subgrades determined fromof laboratory tests CBR- ASTM DI883.The methodology used may not be adequately applied when the C.B.R. value is assumed.of the subgrade related to the dry density equivalent to 95% 6 100% of the Maximum Dry Density - MDS of the Modified Proctor test.The humidity and natural dry density of silt-clay soils have an important influence on the determination of the C.B.R. as has been confirmed in tests on unaltered and compacted samplesComparisons of C.B.R. values ​​were made. obtained from unaltered and compacted samples considering 95% and 100% of the MDS of the Modified Proctor test. Likewise, values ​​of elastic moduli were compared, using an extension of elastic theory.The results indicate that the values ​​of C.B.R. and elastic moduli obtained in samplesunaltered are significantly lower than those determined in compacted samples.The engineering practice for determining the C.B.R. of the subgrade based on unaltered samples is almost not used in Peru, due to this, premature failures of pavements occur due to under-sizing in the design.Actualmente en el Perú, el diseño de estructuras de pavimentos considera generalmente valores de capacidad de soporte de subrasantes arenosas y limo-arcillosas determinados a partir de ensayos de laboratorio CBR- ASTM DI883.La metodología utilizada puede no ser adecuadamente aplicada cuando se asume el valor C.B.R. de la sub-rasante relacionado a la densidad seca equivalente al 95% 6 100% de la Máxima Densidad Seca - MDS del ensayo Proctor Modificado.La humedad y la densidad seca natural de los suelos limo-arcillosos tienen una influencia importante en la determinación del C.B.R. como se ha podido comprobar en las pruebas sobre muestras inalteradas y compactadas. Se realizaron comparaciones de valores C.B.R. obtenidos de muestras inalteradas y compactadas considerando el 95% y 100% de la MDS del ensayo Proctor Modificado. Asimismo se compararon valores de módulos elásticos, utilizando una extensión de la teoría elástica.Los resultados indican que los valores de C.B.R. y módulos elásticos obtenidos en muestrasinalteradas son significativamente inferiores a es a los determinados en muestras compactadas.La práctica ingenieril para la determinación del C.B.R. de la sub-rasante basados en muestras inalteradas es casi no utilizada en el Perú, debido a ello, se presentan fallas prematuras de pavimentos por sub-dimensionamiento en el diseño.Universidad Nacional de Ingeniería2001-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionArtículo evaluado por paresapplication/pdfhttps://revistas.uni.edu.pe/index.php/tecnia/article/view/52210.21754/tecnia.v11i2.522TECNIA; Vol. 11 No. 2 (2001)TECNIA; Vol. 11 Núm. 2 (2001)2309-04130375-7765reponame:Revistas - Universidad Nacional de Ingenieríainstname:Universidad Nacional de Ingenieríainstacron:UNIspahttps://revistas.uni.edu.pe/index.php/tecnia/article/view/522/485Derechos de autor 2001 TECNIAhttp://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessoai:oai:revistas.uni.edu.pe:article/5222023-11-07T14:59:14Z
dc.title.none.fl_str_mv C,B,R, for Sandy and Silt-Clay Subgrades
C,B,R, de Subrasantes Arenosas y Limo-Arcillosas
title C,B,R, for Sandy and Silt-Clay Subgrades
spellingShingle C,B,R, for Sandy and Silt-Clay Subgrades
Ordoñez Huaman, Abel
title_short C,B,R, for Sandy and Silt-Clay Subgrades
title_full C,B,R, for Sandy and Silt-Clay Subgrades
title_fullStr C,B,R, for Sandy and Silt-Clay Subgrades
title_full_unstemmed C,B,R, for Sandy and Silt-Clay Subgrades
title_sort C,B,R, for Sandy and Silt-Clay Subgrades
dc.creator.none.fl_str_mv Ordoñez Huaman, Abel
Minaya González, Silene
author Ordoñez Huaman, Abel
author_facet Ordoñez Huaman, Abel
Minaya González, Silene
author_role author
author2 Minaya González, Silene
author2_role author
description Currently in Peru, the design of pavement structures generally considers support capacity values ​​of sandy and silt-clayey subgrades determined fromof laboratory tests CBR- ASTM DI883.The methodology used may not be adequately applied when the C.B.R. value is assumed.of the subgrade related to the dry density equivalent to 95% 6 100% of the Maximum Dry Density - MDS of the Modified Proctor test.The humidity and natural dry density of silt-clay soils have an important influence on the determination of the C.B.R. as has been confirmed in tests on unaltered and compacted samplesComparisons of C.B.R. values ​​were made. obtained from unaltered and compacted samples considering 95% and 100% of the MDS of the Modified Proctor test. Likewise, values ​​of elastic moduli were compared, using an extension of elastic theory.The results indicate that the values ​​of C.B.R. and elastic moduli obtained in samplesunaltered are significantly lower than those determined in compacted samples.The engineering practice for determining the C.B.R. of the subgrade based on unaltered samples is almost not used in Peru, due to this, premature failures of pavements occur due to under-sizing in the design.
publishDate 2001
dc.date.none.fl_str_mv 2001-12-01
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Artículo evaluado por pares
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://revistas.uni.edu.pe/index.php/tecnia/article/view/522
10.21754/tecnia.v11i2.522
url https://revistas.uni.edu.pe/index.php/tecnia/article/view/522
identifier_str_mv 10.21754/tecnia.v11i2.522
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv https://revistas.uni.edu.pe/index.php/tecnia/article/view/522/485
dc.rights.none.fl_str_mv Derechos de autor 2001 TECNIA
http://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Derechos de autor 2001 TECNIA
http://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidad Nacional de Ingeniería
publisher.none.fl_str_mv Universidad Nacional de Ingeniería
dc.source.none.fl_str_mv TECNIA; Vol. 11 No. 2 (2001)
TECNIA; Vol. 11 Núm. 2 (2001)
2309-0413
0375-7765
reponame:Revistas - Universidad Nacional de Ingeniería
instname:Universidad Nacional de Ingeniería
instacron:UNI
instname_str Universidad Nacional de Ingeniería
instacron_str UNI
institution UNI
reponame_str Revistas - Universidad Nacional de Ingeniería
collection Revistas - Universidad Nacional de Ingeniería
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1833562778384728064
score 13.887938
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).