Exportación Completada — 

Comparison of the precision of the working length of four electronic apical locators with stainless steel files and titanium nickel in mesiovestibular ducts of first lower molars.

Descripción del Articulo

Objective: The purpose of this study was to compare the precision of the working length of Root ZX mini, Proper Pixi, Woodpex III and Raypex 6 using VDW C-Pilot No. 15 with Maillefer nickel titanium No. 15 and stainless steel files in mesiovestibular ducts of first lower molars. Materialsand methods...

Descripción completa

Detalles Bibliográficos
Autores: Mio-Suclupe, Rosa Eudocia, García-Rupaya, Carmen Rosa
Formato: artículo
Fecha de Publicación:2020
Institución:Universidad Científica del Sur
Repositorio:Revistas - Universidad Científica del Sur
Lenguaje:español
OAI Identifier:oai:revistas.cientifica.edu.pe:article/746
Enlace del recurso:https://revistas.cientifica.edu.pe/index.php/odontologica/article/view/746
Nivel de acceso:acceso abierto
Materia:localizador apical electrónico
limas de acero inoxidable y de níquel-titanio
Proper Pixi
Root ZX min
Woodpex III
Raypex 6
longitud de trabajo
electronic apex locator
stainless steel and nickel titanium files
Root ZX mini
working length
Descripción
Sumario:Objective: The purpose of this study was to compare the precision of the working length of Root ZX mini, Proper Pixi, Woodpex III and Raypex 6 using VDW C-Pilot No. 15 with Maillefer nickel titanium No. 15 and stainless steel files in mesiovestibular ducts of first lower molars. Materialsand methods: This was an experimental in vitro study, including 35 mesiobuccal canals of lower first molars. The real length of 4 electronic apical locators, Root ZX mini, Proper Pixi, Woodpex III and Raypex6, was determined with a digital Vernier caliper, and electronic measurementswere recorded using stainless steel and nickel titanium files. Results: There were no statistically significant differences between the real and the electronic lengths of the different tools studied (p <0.05). Conclusions: Statistically significant differences were obtained when comparing theprecision of Root ZX mini, Proper Pixi, Woodpex III and Raypex 6 with stainless steel files, while the precision of nickel titanium files was not affected.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).