Microleakage in indirect partial restorations cemented with self-adhesive dual resin cements
Descripción del Articulo
The aim of this study is to compare in vitro the degree of marginal microleakage in pressed ceramic inlays made with two self-adhesive dual resin cements seT PP (SDI) and RelyX U200 (3M ESPE). Forty upper and lower premolars extracted for orthodontic reasons were evaluated and divided into two group...
| Autores: | , |
|---|---|
| Formato: | artículo |
| Fecha de Publicación: | 2019 |
| Institución: | Universidad Científica del Sur |
| Repositorio: | Revistas - Universidad Científica del Sur |
| Lenguaje: | español |
| OAI Identifier: | oai:revistas.cientifica.edu.pe:article/530 |
| Enlace del recurso: | https://revistas.cientifica.edu.pe/index.php/odontologica/article/view/530 |
| Nivel de acceso: | acceso abierto |
| Materia: | Microfiltración Cerámica Cementos resinosos microfiltration ceramics resinous cements |
| id |
REVUCS_c69e3e8df28937d258bdbdd3912172bd |
|---|---|
| oai_identifier_str |
oai:revistas.cientifica.edu.pe:article/530 |
| network_acronym_str |
REVUCS |
| network_name_str |
Revistas - Universidad Científica del Sur |
| repository_id_str |
. |
| dc.title.none.fl_str_mv |
Microleakage in indirect partial restorations cemented with self-adhesive dual resin cements Microfiltración en restauraciones parciales indirectas cementadas con cementos resinosos duales autoadhesivos |
| title |
Microleakage in indirect partial restorations cemented with self-adhesive dual resin cements |
| spellingShingle |
Microleakage in indirect partial restorations cemented with self-adhesive dual resin cements Zaga Bendezú, Javier Cleto Microfiltración Cerámica Cementos resinosos microfiltration ceramics resinous cements |
| title_short |
Microleakage in indirect partial restorations cemented with self-adhesive dual resin cements |
| title_full |
Microleakage in indirect partial restorations cemented with self-adhesive dual resin cements |
| title_fullStr |
Microleakage in indirect partial restorations cemented with self-adhesive dual resin cements |
| title_full_unstemmed |
Microleakage in indirect partial restorations cemented with self-adhesive dual resin cements |
| title_sort |
Microleakage in indirect partial restorations cemented with self-adhesive dual resin cements |
| dc.creator.none.fl_str_mv |
Zaga Bendezú, Javier Cleto López-Flores, Ana Isabel |
| author |
Zaga Bendezú, Javier Cleto |
| author_facet |
Zaga Bendezú, Javier Cleto López-Flores, Ana Isabel |
| author_role |
author |
| author2 |
López-Flores, Ana Isabel |
| author2_role |
author |
| dc.subject.none.fl_str_mv |
Microfiltración Cerámica Cementos resinosos microfiltration ceramics resinous cements |
| topic |
Microfiltración Cerámica Cementos resinosos microfiltration ceramics resinous cements |
| description |
The aim of this study is to compare in vitro the degree of marginal microleakage in pressed ceramic inlays made with two self-adhesive dual resin cements seT PP (SDI) and RelyX U200 (3M ESPE). Forty upper and lower premolars extracted for orthodontic reasons were evaluated and divided into two groups according to assigned cement (n = 20). Then, the preparation of class II type cavities, approximately 3 mm wide, was performed in the occlusal and proximal box; and 2 mm thick on the gingival floor and occlusal wall. They were indirectly restored with IPS e.max Press (Ivoclar Vivadent) ceramic pressed restorations, cemented with the types of cement studied according to the manufacturer's specifications. The specimens were kept in a jar and taken to thermocycling; then, cross sections were made to the crowns and the degree of microleakage was evaluated by means of a stereoscope. When comparing the microleakage between the seT PP cement and RelyX U200, it was concluded that there is no statistically significant association between the degree of microleakage and the type of cement (Pearson's Chi-square test; p > 0.05), and when observing the degree of microleakage of seT PP and RelyX U200 in the cementation of IPS e.max Pressed ceramic inlays. In conclusion, no significant differences were found between the two self-adhesive resinous cement. In both, non-microfiltration prevailed; however, for seT PP, microleakage was 17.5% in 1/3 of the cervical wall. |
| publishDate |
2019 |
| dc.date.none.fl_str_mv |
2019-12-19 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
https://revistas.cientifica.edu.pe/index.php/odontologica/article/view/530 10.21142/2523-2754-0702-2019-33-41 |
| url |
https://revistas.cientifica.edu.pe/index.php/odontologica/article/view/530 |
| identifier_str_mv |
10.21142/2523-2754-0702-2019-33-41 |
| dc.language.none.fl_str_mv |
spa |
| language |
spa |
| dc.relation.none.fl_str_mv |
https://revistas.cientifica.edu.pe/index.php/odontologica/article/view/530/611 |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Carrera de Estomatología de la Universidad Científica del Sur |
| publisher.none.fl_str_mv |
Carrera de Estomatología de la Universidad Científica del Sur |
| dc.source.none.fl_str_mv |
Revista Científica Odontológica; Vol. 7 Núm. 2 (2019); 33-41 Revista Científica Odontológica; Vol. 7 No. 2 (2019); 33-41 2523-2754 2310-2594 10.21142/2523-2754-0702-2019 reponame:Revistas - Universidad Científica del Sur instname:Universidad Científica del Sur instacron:CIENTÍFICA |
| instname_str |
Universidad Científica del Sur |
| instacron_str |
CIENTÍFICA |
| institution |
CIENTÍFICA |
| reponame_str |
Revistas - Universidad Científica del Sur |
| collection |
Revistas - Universidad Científica del Sur |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1846879641696993280 |
| spelling |
Microleakage in indirect partial restorations cemented with self-adhesive dual resin cementsMicrofiltración en restauraciones parciales indirectas cementadas con cementos resinosos duales autoadhesivosZaga Bendezú, Javier CletoLópez-Flores, Ana IsabelMicrofiltraciónCerámicaCementos resinososmicrofiltrationceramicsresinous cementsThe aim of this study is to compare in vitro the degree of marginal microleakage in pressed ceramic inlays made with two self-adhesive dual resin cements seT PP (SDI) and RelyX U200 (3M ESPE). Forty upper and lower premolars extracted for orthodontic reasons were evaluated and divided into two groups according to assigned cement (n = 20). Then, the preparation of class II type cavities, approximately 3 mm wide, was performed in the occlusal and proximal box; and 2 mm thick on the gingival floor and occlusal wall. They were indirectly restored with IPS e.max Press (Ivoclar Vivadent) ceramic pressed restorations, cemented with the types of cement studied according to the manufacturer's specifications. The specimens were kept in a jar and taken to thermocycling; then, cross sections were made to the crowns and the degree of microleakage was evaluated by means of a stereoscope. When comparing the microleakage between the seT PP cement and RelyX U200, it was concluded that there is no statistically significant association between the degree of microleakage and the type of cement (Pearson's Chi-square test; p > 0.05), and when observing the degree of microleakage of seT PP and RelyX U200 in the cementation of IPS e.max Pressed ceramic inlays. In conclusion, no significant differences were found between the two self-adhesive resinous cement. In both, non-microfiltration prevailed; however, for seT PP, microleakage was 17.5% in 1/3 of the cervical wall.El objetivo de este estudio es comparar in vitro el grado de microfiltración marginal en incrustaciones de cerámica inyectada realizadas con dos cementos resinosos duales autoadhesivos seT PP (SDI) y RelyX U200 (3M ESPE). Se evaluaron 40 premolares superiores e inferiores extraídos por motivos ortodónticos y se dividieron en dos grupos según cemento asignado (n = 20). Luego, se realizó la preparación de cavidades tipo clase II, de aproximadamente 3 mm de ancho en la caja oclusal y proximal; y 2 mm de espesor en el piso gingival y la pared oclusal. Se restauraron de manera indirecta con restauraciones inyectadas de cerámica IPS e.max Press (Ivoclar Vivadent), se cementaron con los cementos estudiados según las especificaciones del fabricante. Los especímenes fueron guardados en un frasco y llevados a termociclado; luego, se realizaron cortes transversales a las coronas y se evaluó el grado de microfiltración por medio de un estereoscopio. Al comparar la microfiltración entre el cemento seT PP y RelyX U200, se concluyó que no existe una asociación estadísticamente significativa entre el grado de microfiltración y el tipo de cemento (prueba de Chi-cuadrado de Pearson; p > 0,05) y al observar el grado de microfiltración del seT PP y el RelyX U200 en la cementación de incrustaciones cerámicas inyectadas IPS e.max Press. En conclusión, no se hallaron diferencias significativas entre los dos cementos resinosos autoadhesivos. En ambos prevaleció la no microfiltración; sin embargo, para seT PP, la microfiltración fue del 17,5% en 1/3 de la pared cervical.Carrera de Estomatología de la Universidad Científica del Sur2019-12-19info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistas.cientifica.edu.pe/index.php/odontologica/article/view/53010.21142/2523-2754-0702-2019-33-41Revista Científica Odontológica; Vol. 7 Núm. 2 (2019); 33-41Revista Científica Odontológica; Vol. 7 No. 2 (2019); 33-412523-27542310-259410.21142/2523-2754-0702-2019reponame:Revistas - Universidad Científica del Surinstname:Universidad Científica del Surinstacron:CIENTÍFICAspahttps://revistas.cientifica.edu.pe/index.php/odontologica/article/view/530/611info:eu-repo/semantics/openAccessoai:revistas.cientifica.edu.pe:article/5302022-05-18T11:49:07Z |
| score |
12.605999 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).