An engineering system capable of degrading biologically in continous operation IWWs (industrial waste water) contaminated with heavy metals using native strains of Aspergillus sp. using a new technology was implemented efficiently incorporating plug flow reactor. The system was configured with eight...
| Autores: | , , , |
|---|---|
| Formato: | artículo |
| Fecha de Publicación: | 2019 |
| Institución: | Universidad Católica de Santa María |
| Repositorio: | Revistas - Universidad Católica de Santa María |
| Lenguaje: | español |
| OAI Identifier: | oai:ojs.revistas.ucsm.edu.pe:article/214 |
| Enlace del recurso: | https://revistas.ucsm.edu.pe/ojs/index.php/veritas/article/view/214 |
| Nivel de acceso: | acceso abierto |
| Materia: | Sistema de ingeniería Aspergillus sp Biodegradación Aguas residuales industriales (ARI‘s) Metales pesados |
| id |
REVUCSM_d254c8a89f0ad5d78d1179815de20e67 |
|---|---|
| oai_identifier_str |
oai:ojs.revistas.ucsm.edu.pe:article/214 |
| network_acronym_str |
REVUCSM |
| network_name_str |
Revistas - Universidad Católica de Santa María |
| repository_id_str |
|
| spelling |
Engineering system for biological degradation of IWW’s contaminated with heavy metals using native Strains of Aspergillus sp. Sistema de ingeniería para la degradación biológica de ARI‘s contaminadas con metales pesados utilizando cepas nativas de Aspergillus sp.Francisco J. RoqueEliana C. CalleGrecia E. BarrigaCynthia J. HanccoSistema de ingenieríaAspergillus spBiodegradaciónAguas residuales industriales (ARI‘s)Metales pesadosAn engineering system capable of degrading biologically in continous operation IWWs (industrial waste water) contaminated with heavy metals using native strains of Aspergillus sp. using a new technology was implemented efficiently incorporating plug flow reactor. The system was configured with eight fully stainless steel tubes packed with immobilized cells of Aspergillus sp. circularly arranged within a cylindrical tank way to provide heating jacket thermostating system possessing bioscrubber fungal strains to develop its maximum performance at 30 ± 1°C, likewise, was also an electric 2 HP nominal power centrifuge which was fed wastewater and recirculated through the system to get their purging heavy metals (Cu, Zn, Cd and Pb) so that when the system worked was allowed into the raw water to the tubes containing immobilized fungal cells and with which contact is executed removal and cleaning of heavy metals described above flowing water. The system used in its design included peripherals like two water tanks, one of them was found in raw wastewater and treated water the other got to operate the system and that proved to be the desired effluent, both are connected to the pump centrifuge tubes and packaged with fungal strains. Un sistema innovador de ingeniería que degrado biológicamente en operación continua ARI’s (aguas residuales industriales) contaminadas con metales pesados utilizando cepas nativas de Aspergillus sp. fue implementado eficientemente incorporando tecnología de flujo pistón. Dicho sistema fue configurado con ocho tubos de acero inoxidable completamente empaquetados con células inmovilizadas de Aspergillus sp. Ordenados circularmente dentro de un tanque cilíndrico a manera de chaqueta de calentamiento para proveer termostatización del sistema biodegradador que poseen a las cepas fungales para que desarrollen su máxima performance a 30 ± 1°C; así mismo, se insertó una electrobomba centrífuga de 2 1-IP de potencia nominal con la cual se aumentó y recirculó el agua residual a través del sistema para conseguir su depuración en metales pesados (Cu, Zn, Cd y Pb) de modo que cuando el sistema funcionó se permitió el ingreso del agua cruda a los tubos que contuvieron las células fungales inmovilizadas y con cuyo contacto se ejecutó la remoción y depuración de los metales pesados anteriormente descritos del agua fluyente. El sistema utilizado incluyó en su diseño algunos periféricos como dos depósitos de agua; en uno de ellos se encontró el agua residual cruda y en el otro el agua depurada conseguida al funcionar el sistema y que resultó ser el efluente deseado; ambos estuvieron conectados a la bomba centrífuga y a los tubos empaquetados cori las cepas fungales. Universidad Católica de Santa María2019-06-13info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistas.ucsm.edu.pe/ojs/index.php/veritas/article/view/214Veritas; Vol. 14 Núm. 1 (2013): VÉRITAS: Investigación, Innovación y Desarrollo; 75-92Veritas; Vol. 14 Núm. 1 (2013): VÉRITAS: Investigación, Innovación y Desarrollo; 75-92Veritas; Vol. 14 Núm. 1 (2013): VÉRITAS: Investigación, Innovación y Desarrollo; 75-921684-78221684-7822reponame:Revistas - Universidad Católica de Santa Maríainstname:Universidad Católica de Santa Maríainstacron:UCSMspahttps://revistas.ucsm.edu.pe/ojs/index.php/veritas/article/view/214/140Derechos de autor 2019 Veritasinfo:eu-repo/semantics/openAccessoai:ojs.revistas.ucsm.edu.pe:article/2142019-06-13T17:05:35Z |
| dc.title.none.fl_str_mv |
Engineering system for biological degradation of IWW’s contaminated with heavy metals using native Strains of Aspergillus sp. Sistema de ingeniería para la degradación biológica de ARI‘s contaminadas con metales pesados utilizando cepas nativas de Aspergillus sp. |
| title |
Engineering system for biological degradation of IWW’s contaminated with heavy metals using native Strains of Aspergillus sp. |
| spellingShingle |
Engineering system for biological degradation of IWW’s contaminated with heavy metals using native Strains of Aspergillus sp. Francisco J. Roque Sistema de ingeniería Aspergillus sp Biodegradación Aguas residuales industriales (ARI‘s) Metales pesados |
| title_short |
Engineering system for biological degradation of IWW’s contaminated with heavy metals using native Strains of Aspergillus sp. |
| title_full |
Engineering system for biological degradation of IWW’s contaminated with heavy metals using native Strains of Aspergillus sp. |
| title_fullStr |
Engineering system for biological degradation of IWW’s contaminated with heavy metals using native Strains of Aspergillus sp. |
| title_full_unstemmed |
Engineering system for biological degradation of IWW’s contaminated with heavy metals using native Strains of Aspergillus sp. |
| title_sort |
Engineering system for biological degradation of IWW’s contaminated with heavy metals using native Strains of Aspergillus sp. |
| dc.creator.none.fl_str_mv |
Francisco J. Roque Eliana C. Calle Grecia E. Barriga Cynthia J. Hancco |
| author |
Francisco J. Roque |
| author_facet |
Francisco J. Roque Eliana C. Calle Grecia E. Barriga Cynthia J. Hancco |
| author_role |
author |
| author2 |
Eliana C. Calle Grecia E. Barriga Cynthia J. Hancco |
| author2_role |
author author author |
| dc.subject.none.fl_str_mv |
Sistema de ingeniería Aspergillus sp Biodegradación Aguas residuales industriales (ARI‘s) Metales pesados |
| topic |
Sistema de ingeniería Aspergillus sp Biodegradación Aguas residuales industriales (ARI‘s) Metales pesados |
| description |
An engineering system capable of degrading biologically in continous operation IWWs (industrial waste water) contaminated with heavy metals using native strains of Aspergillus sp. using a new technology was implemented efficiently incorporating plug flow reactor. The system was configured with eight fully stainless steel tubes packed with immobilized cells of Aspergillus sp. circularly arranged within a cylindrical tank way to provide heating jacket thermostating system possessing bioscrubber fungal strains to develop its maximum performance at 30 ± 1°C, likewise, was also an electric 2 HP nominal power centrifuge which was fed wastewater and recirculated through the system to get their purging heavy metals (Cu, Zn, Cd and Pb) so that when the system worked was allowed into the raw water to the tubes containing immobilized fungal cells and with which contact is executed removal and cleaning of heavy metals described above flowing water. The system used in its design included peripherals like two water tanks, one of them was found in raw wastewater and treated water the other got to operate the system and that proved to be the desired effluent, both are connected to the pump centrifuge tubes and packaged with fungal strains. |
| publishDate |
2019 |
| dc.date.none.fl_str_mv |
2019-06-13 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
https://revistas.ucsm.edu.pe/ojs/index.php/veritas/article/view/214 |
| url |
https://revistas.ucsm.edu.pe/ojs/index.php/veritas/article/view/214 |
| dc.language.none.fl_str_mv |
spa |
| language |
spa |
| dc.relation.none.fl_str_mv |
https://revistas.ucsm.edu.pe/ojs/index.php/veritas/article/view/214/140 |
| dc.rights.none.fl_str_mv |
Derechos de autor 2019 Veritas info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
Derechos de autor 2019 Veritas |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Universidad Católica de Santa María |
| publisher.none.fl_str_mv |
Universidad Católica de Santa María |
| dc.source.none.fl_str_mv |
Veritas; Vol. 14 Núm. 1 (2013): VÉRITAS: Investigación, Innovación y Desarrollo; 75-92 Veritas; Vol. 14 Núm. 1 (2013): VÉRITAS: Investigación, Innovación y Desarrollo; 75-92 Veritas; Vol. 14 Núm. 1 (2013): VÉRITAS: Investigación, Innovación y Desarrollo; 75-92 1684-7822 1684-7822 reponame:Revistas - Universidad Católica de Santa María instname:Universidad Católica de Santa María instacron:UCSM |
| instname_str |
Universidad Católica de Santa María |
| instacron_str |
UCSM |
| institution |
UCSM |
| reponame_str |
Revistas - Universidad Católica de Santa María |
| collection |
Revistas - Universidad Católica de Santa María |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1846698416548085760 |
| score |
13.140231 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).