REMOVAL OF CHROMIUM AND CHEMICAL OXYGEN DEMAND OF TANNERY WASTEWATER BY ELECTROCOAGULATION
Descripción del Articulo
Removal of trivalent chromium and chemical oxygen demand (DQO) of tannery wastewater samples by electrocoagulation (EC) from discontinuous operation electrochemical reactor were studied. The influence of times (15 to 45 min), voltages (5 to 10 V), dilutions (0 to 2) and their interactions in EC proc...
Autores: | , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2017 |
Institución: | Sociedad Química del Perú |
Repositorio: | Revista de la Sociedad Química del Perú |
Lenguaje: | español |
OAI Identifier: | oai:rsqp.revistas.sqperu.org.pe:article/117 |
Enlace del recurso: | http://revistas.sqperu.org.pe/index.php/revistasqperu/article/view/117 |
Nivel de acceso: | acceso abierto |
Materia: | Electrocoagulation trivalent chromium chemical demand oxygen Electrocoagulación cromo trivalente demanda química de oxígeno |
id |
REVSQP_e889eb092c49cca3dcf9d27f9a6b18fc |
---|---|
oai_identifier_str |
oai:rsqp.revistas.sqperu.org.pe:article/117 |
network_acronym_str |
REVSQP |
network_name_str |
Revista de la Sociedad Química del Perú |
repository_id_str |
|
spelling |
REMOVAL OF CHROMIUM AND CHEMICAL OXYGEN DEMAND OF TANNERY WASTEWATER BY ELECTROCOAGULATIONREMOCIÓN DE CROMO Y DEMANDA QUÍMICA DE OXÍGENO DE AGUAS RESIDUALES DE CURTIEMBRE POR ELECTROCOAGULACIÓNMayta, RoddyMayta, JhonyElectrocoagulationtrivalent chromiumchemical demand oxygenElectrocoagulacióncromo trivalentedemanda química de oxígenoRemoval of trivalent chromium and chemical oxygen demand (DQO) of tannery wastewater samples by electrocoagulation (EC) from discontinuous operation electrochemical reactor were studied. The influence of times (15 to 45 min), voltages (5 to 10 V), dilutions (0 to 2) and their interactions in EC process were significant (p <0.05). Increases in pH, temperature, and decreases of conductivity of the samples during the EC process were observed. The maximum removal of trivalent chromium (~98 %) and DQO (~48 %) was obtained with the treatment (45 min, 10 V and dilution of 2). Likewise, the experimental results allowed to develop mathematical models for the removal of trivalent chromium and DQO, respectively.Se estudió la remoción de cromo III y demanda química de oxígeno (DQO) de muestras de aguas residuales de curtiduría por electrocoagulación (EC) en un reactor electroquímico de operación discontinua. La influencia de los tiempos (15 a 45 min), voltajes (5 a 10 V), diluciones (0 a 2) y sus interacciones en el proceso de EC fueron significativos (p<0,05). Durante el proceso de EC de las muestras se observó incrementos de pH, temperatura y disminuciones de la conductividad. La máxima remoción de cromo III (~98 %) y DQO (~48 %) fue obtenida con el tratamiento (45 min, 10 V y dilución de 2). Asimismo, los resultados experimentales permitieron desarrollar modelos matemáticos para la remoción de cromo III y DQO, respectivamente.Sociedad Química del Perú2017-09-30info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontexttextoapplication/pdfhttp://revistas.sqperu.org.pe/index.php/revistasqperu/article/view/11710.37761/rsqp.v83i3.117Revista de la Sociedad Química del Perú; Vol. 83 Núm. 3 (2017): Revista de la Sociedad Química del Perú; 331 - 340Journal of the Chemical Society of Peru; Vol. 83 No. 3 (2017): Journal of Sociedad Química del Perú; 331 - 3402309-87401810-634X10.37761/rsqp.v83i3reponame:Revista de la Sociedad Química del Perúinstname:Sociedad Química del Perúinstacron:SQPspahttp://revistas.sqperu.org.pe/index.php/revistasqperu/article/view/117/9920172017Derechos de autor 2017 Sociedad Química del Perúhttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessoai:rsqp.revistas.sqperu.org.pe:article/1172020-03-04T03:33:41Z |
dc.title.none.fl_str_mv |
REMOVAL OF CHROMIUM AND CHEMICAL OXYGEN DEMAND OF TANNERY WASTEWATER BY ELECTROCOAGULATION REMOCIÓN DE CROMO Y DEMANDA QUÍMICA DE OXÍGENO DE AGUAS RESIDUALES DE CURTIEMBRE POR ELECTROCOAGULACIÓN |
title |
REMOVAL OF CHROMIUM AND CHEMICAL OXYGEN DEMAND OF TANNERY WASTEWATER BY ELECTROCOAGULATION |
spellingShingle |
REMOVAL OF CHROMIUM AND CHEMICAL OXYGEN DEMAND OF TANNERY WASTEWATER BY ELECTROCOAGULATION Mayta, Roddy Electrocoagulation trivalent chromium chemical demand oxygen Electrocoagulación cromo trivalente demanda química de oxígeno |
title_short |
REMOVAL OF CHROMIUM AND CHEMICAL OXYGEN DEMAND OF TANNERY WASTEWATER BY ELECTROCOAGULATION |
title_full |
REMOVAL OF CHROMIUM AND CHEMICAL OXYGEN DEMAND OF TANNERY WASTEWATER BY ELECTROCOAGULATION |
title_fullStr |
REMOVAL OF CHROMIUM AND CHEMICAL OXYGEN DEMAND OF TANNERY WASTEWATER BY ELECTROCOAGULATION |
title_full_unstemmed |
REMOVAL OF CHROMIUM AND CHEMICAL OXYGEN DEMAND OF TANNERY WASTEWATER BY ELECTROCOAGULATION |
title_sort |
REMOVAL OF CHROMIUM AND CHEMICAL OXYGEN DEMAND OF TANNERY WASTEWATER BY ELECTROCOAGULATION |
dc.creator.none.fl_str_mv |
Mayta, Roddy Mayta, Jhony |
author |
Mayta, Roddy |
author_facet |
Mayta, Roddy Mayta, Jhony |
author_role |
author |
author2 |
Mayta, Jhony |
author2_role |
author |
dc.subject.none.fl_str_mv |
Electrocoagulation trivalent chromium chemical demand oxygen Electrocoagulación cromo trivalente demanda química de oxígeno |
topic |
Electrocoagulation trivalent chromium chemical demand oxygen Electrocoagulación cromo trivalente demanda química de oxígeno |
description |
Removal of trivalent chromium and chemical oxygen demand (DQO) of tannery wastewater samples by electrocoagulation (EC) from discontinuous operation electrochemical reactor were studied. The influence of times (15 to 45 min), voltages (5 to 10 V), dilutions (0 to 2) and their interactions in EC process were significant (p <0.05). Increases in pH, temperature, and decreases of conductivity of the samples during the EC process were observed. The maximum removal of trivalent chromium (~98 %) and DQO (~48 %) was obtained with the treatment (45 min, 10 V and dilution of 2). Likewise, the experimental results allowed to develop mathematical models for the removal of trivalent chromium and DQO, respectively. |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017-09-30 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion text texto |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://revistas.sqperu.org.pe/index.php/revistasqperu/article/view/117 10.37761/rsqp.v83i3.117 |
url |
http://revistas.sqperu.org.pe/index.php/revistasqperu/article/view/117 |
identifier_str_mv |
10.37761/rsqp.v83i3.117 |
dc.language.none.fl_str_mv |
spa |
language |
spa |
dc.relation.none.fl_str_mv |
http://revistas.sqperu.org.pe/index.php/revistasqperu/article/view/117/99 |
dc.rights.none.fl_str_mv |
Derechos de autor 2017 Sociedad Química del Perú https://creativecommons.org/licenses/by/4.0 info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Derechos de autor 2017 Sociedad Química del Perú https://creativecommons.org/licenses/by/4.0 |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.coverage.none.fl_str_mv |
2017 2017 |
dc.publisher.none.fl_str_mv |
Sociedad Química del Perú |
publisher.none.fl_str_mv |
Sociedad Química del Perú |
dc.source.none.fl_str_mv |
Revista de la Sociedad Química del Perú; Vol. 83 Núm. 3 (2017): Revista de la Sociedad Química del Perú; 331 - 340 Journal of the Chemical Society of Peru; Vol. 83 No. 3 (2017): Journal of Sociedad Química del Perú; 331 - 340 2309-8740 1810-634X 10.37761/rsqp.v83i3 reponame:Revista de la Sociedad Química del Perú instname:Sociedad Química del Perú instacron:SQP |
instname_str |
Sociedad Química del Perú |
instacron_str |
SQP |
institution |
SQP |
reponame_str |
Revista de la Sociedad Química del Perú |
collection |
Revista de la Sociedad Química del Perú |
repository.name.fl_str_mv |
|
repository.mail.fl_str_mv |
|
_version_ |
1842801570646851584 |
score |
12.660138 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).