DETERMINATION OF THE CONCENTRATION OF CHITOSAN IN POWDER BY CAPILLARY VISCOSIMETRY
Descripción del Articulo
The objective of this work has been to develop a procedure for the determination of the concentration of chitosan in powder samples, by capillary viscosimetry of Ostwald (capillary of 0.55 ± 0.02 mm internal diameter). Standard chitosan solutions between 461 mg/liter up to 9138 mg/liter and pH 1.24...
| Autores: | , |
|---|---|
| Formato: | artículo |
| Fecha de Publicación: | 2020 |
| Institución: | Sociedad Química del Perú |
| Repositorio: | Revista de la Sociedad Química del Perú |
| Lenguaje: | español |
| OAI Identifier: | oai:rsqp.revistas.sqperu.org.pe:article/269 |
| Enlace del recurso: | http://revistas.sqperu.org.pe/index.php/revistasqperu/article/view/269 |
| Nivel de acceso: | acceso abierto |
| Materia: | chitosan viscosity pH concentration quitosano viscosidad concentración |
| id |
REVSQP_c820571b492363ebedbf1cbbfad47822 |
|---|---|
| oai_identifier_str |
oai:rsqp.revistas.sqperu.org.pe:article/269 |
| network_acronym_str |
REVSQP |
| network_name_str |
Revista de la Sociedad Química del Perú |
| repository_id_str |
|
| spelling |
DETERMINATION OF THE CONCENTRATION OF CHITOSAN IN POWDER BY CAPILLARY VISCOSIMETRYDETERMINACIÓN DE LA CONCENTRACIÓN DE QUITOSANO EN POLVO POR VISCOSIMETRÍA CAPILARRodríguez Llegado, Agustín A.Cjuno H, Jesús A.chitosanviscositypHconcentrationquitosanoviscosidadpHconcentraciónThe objective of this work has been to develop a procedure for the determination of the concentration of chitosan in powder samples, by capillary viscosimetry of Ostwald (capillary of 0.55 ± 0.02 mm internal diameter). Standard chitosan solutions between 461 mg/liter up to 9138 mg/liter and pH 1.24 were prepared for all cases. Tests were also carried out at temperatures between 20° to 50°C, observing linearity with the concentration until before 9138 mg/liter. The most important dependence was the relative viscosity (ηr) versus the concentration (concordant with the Poiseuille equation) which in the range 461 mg/liter to 2808 mg/liter gave a linear dependence with r2= 0.995, enabling the analysis of samples for the content of chitosan with consistent results and comparable with the referentials.El objetivo de este trabajo ha sido desarrollar un procedimiento para la determinación de la concentración de quitosano en muestras en polvo, por viscosimetría capilar de Ostwald (capilar de 0,55 ± 0,02 mm de diámetro interno). Se prepararon soluciones de quitosano patrón entre 461 mg/litro hasta 9138 mg/litro y pH 1,24 para todos los casos. Se realizaron también ensayos a temperaturas entre 20° a 50°C observándose linealidad con la concentración hasta antes de 9138,36 mg/litro. La dependencia más importante fue la de viscosidad relativa (ηr) frente a la concentración (concordante con la ecuación de Poiseuille) que en el rango de 461 mg/litro a 2808 mg/litro dio una dependencia lineal con r2=0,995, posibilitando el análisis de muestras para el contenido de quitosano con resultados consistentes y equiparables con los referenciales.Sociedad Química del Perú2020-03-31info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionTexttextoapplication/pdfhttp://revistas.sqperu.org.pe/index.php/revistasqperu/article/view/26910.37761/rsqp.v86i1.269Revista de la Sociedad Química del Perú; Vol. 86 Núm. 1 (2020): Revista de la Sociedad Química del Perú; 24 - 33Journal of the Chemical Society of Peru; Vol. 86 No. 1 (2020): Journal of Sociedad Química del Perú; 24 - 332309-87401810-634X10.37761/rsqp.v86i1reponame:Revista de la Sociedad Química del Perúinstname:Sociedad Química del Perúinstacron:SQPspahttp://revistas.sqperu.org.pe/index.php/revistasqperu/article/view/269/23520202020Derechos de autor 2020 Sociedad Química del Perúhttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessoai:rsqp.revistas.sqperu.org.pe:article/2692020-07-31T15:48:15Z |
| dc.title.none.fl_str_mv |
DETERMINATION OF THE CONCENTRATION OF CHITOSAN IN POWDER BY CAPILLARY VISCOSIMETRY DETERMINACIÓN DE LA CONCENTRACIÓN DE QUITOSANO EN POLVO POR VISCOSIMETRÍA CAPILAR |
| title |
DETERMINATION OF THE CONCENTRATION OF CHITOSAN IN POWDER BY CAPILLARY VISCOSIMETRY |
| spellingShingle |
DETERMINATION OF THE CONCENTRATION OF CHITOSAN IN POWDER BY CAPILLARY VISCOSIMETRY Rodríguez Llegado, Agustín A. chitosan viscosity pH concentration quitosano viscosidad pH concentración |
| title_short |
DETERMINATION OF THE CONCENTRATION OF CHITOSAN IN POWDER BY CAPILLARY VISCOSIMETRY |
| title_full |
DETERMINATION OF THE CONCENTRATION OF CHITOSAN IN POWDER BY CAPILLARY VISCOSIMETRY |
| title_fullStr |
DETERMINATION OF THE CONCENTRATION OF CHITOSAN IN POWDER BY CAPILLARY VISCOSIMETRY |
| title_full_unstemmed |
DETERMINATION OF THE CONCENTRATION OF CHITOSAN IN POWDER BY CAPILLARY VISCOSIMETRY |
| title_sort |
DETERMINATION OF THE CONCENTRATION OF CHITOSAN IN POWDER BY CAPILLARY VISCOSIMETRY |
| dc.creator.none.fl_str_mv |
Rodríguez Llegado, Agustín A. Cjuno H, Jesús A. |
| author |
Rodríguez Llegado, Agustín A. |
| author_facet |
Rodríguez Llegado, Agustín A. Cjuno H, Jesús A. |
| author_role |
author |
| author2 |
Cjuno H, Jesús A. |
| author2_role |
author |
| dc.subject.none.fl_str_mv |
chitosan viscosity pH concentration quitosano viscosidad pH concentración |
| topic |
chitosan viscosity pH concentration quitosano viscosidad pH concentración |
| description |
The objective of this work has been to develop a procedure for the determination of the concentration of chitosan in powder samples, by capillary viscosimetry of Ostwald (capillary of 0.55 ± 0.02 mm internal diameter). Standard chitosan solutions between 461 mg/liter up to 9138 mg/liter and pH 1.24 were prepared for all cases. Tests were also carried out at temperatures between 20° to 50°C, observing linearity with the concentration until before 9138 mg/liter. The most important dependence was the relative viscosity (ηr) versus the concentration (concordant with the Poiseuille equation) which in the range 461 mg/liter to 2808 mg/liter gave a linear dependence with r2= 0.995, enabling the analysis of samples for the content of chitosan with consistent results and comparable with the referentials. |
| publishDate |
2020 |
| dc.date.none.fl_str_mv |
2020-03-31 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Text texto |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
http://revistas.sqperu.org.pe/index.php/revistasqperu/article/view/269 10.37761/rsqp.v86i1.269 |
| url |
http://revistas.sqperu.org.pe/index.php/revistasqperu/article/view/269 |
| identifier_str_mv |
10.37761/rsqp.v86i1.269 |
| dc.language.none.fl_str_mv |
spa |
| language |
spa |
| dc.relation.none.fl_str_mv |
http://revistas.sqperu.org.pe/index.php/revistasqperu/article/view/269/235 |
| dc.rights.none.fl_str_mv |
Derechos de autor 2020 Sociedad Química del Perú https://creativecommons.org/licenses/by/4.0 info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
Derechos de autor 2020 Sociedad Química del Perú https://creativecommons.org/licenses/by/4.0 |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.coverage.none.fl_str_mv |
2020 2020 |
| dc.publisher.none.fl_str_mv |
Sociedad Química del Perú |
| publisher.none.fl_str_mv |
Sociedad Química del Perú |
| dc.source.none.fl_str_mv |
Revista de la Sociedad Química del Perú; Vol. 86 Núm. 1 (2020): Revista de la Sociedad Química del Perú; 24 - 33 Journal of the Chemical Society of Peru; Vol. 86 No. 1 (2020): Journal of Sociedad Química del Perú; 24 - 33 2309-8740 1810-634X 10.37761/rsqp.v86i1 reponame:Revista de la Sociedad Química del Perú instname:Sociedad Química del Perú instacron:SQP |
| instname_str |
Sociedad Química del Perú |
| instacron_str |
SQP |
| institution |
SQP |
| reponame_str |
Revista de la Sociedad Química del Perú |
| collection |
Revista de la Sociedad Química del Perú |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1846606543431139328 |
| score |
13.098175 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).