DETERMINATION OF PYROGALLOL RED ON A GLASSY CARBON ELECTRODE MODIFIED WITH GOLD FILM AND CYSTEAMINE BY ADSORPTION VOLTAMMETRY (AdsV). POSSIBLE USE AS ELECTROCHEMICAL SENSOR
Descripción del Articulo
Interaction pyrogallol red (RP) on glassy carbon electrode surface modified gold film (AUF)and cysteamine (cis) was studied. Bearing in mind the order of the modification, it was foundthat the response of oxidation of RP showed higher current to the electrode modified withgold film electro-deposited...
Autores: | , , , , , , , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2015 |
Institución: | Sociedad Química del Perú |
Repositorio: | Revista de la Sociedad Química del Perú |
Lenguaje: | español |
OAI Identifier: | oai:rsqp.revistas.sqperu.org.pe:article/29 |
Enlace del recurso: | http://revistas.sqperu.org.pe/index.php/revistasqperu/article/view/29 |
Nivel de acceso: | acceso abierto |
Materia: | Red pyrogallol adsorption voltammetry cysteamine gold film Rojo de pirogalol voltamperometría de adsorción cisteamina película de oro |
id |
REVSQP_81db7c29a6a965d0b1d40a9c9cfcd316 |
---|---|
oai_identifier_str |
oai:rsqp.revistas.sqperu.org.pe:article/29 |
network_acronym_str |
REVSQP |
network_name_str |
Revista de la Sociedad Química del Perú |
repository_id_str |
|
spelling |
DETERMINATION OF PYROGALLOL RED ON A GLASSY CARBON ELECTRODE MODIFIED WITH GOLD FILM AND CYSTEAMINE BY ADSORPTION VOLTAMMETRY (AdsV). POSSIBLE USE AS ELECTROCHEMICAL SENSORDETERMINACIÓN DE ROJO DE PIROGALOL USANDO UN ELECTRODO DE CARBONO VÍTREO MODIFICADO CON PELÍCULA DE ORO Y CISTEAMINA POR VOLTAMPEROMETRÍA DE ADSORCIÓN (AdSV). POSIBLE USO COMO SENSOR ELECTROQUÍMICOBolaños, KarenLeiva, YaritzaMariño, AdriánCuéllar, ClaudiaQuimbaya, CarolinaCastiblanco, PaolaOtiniano, ManuelNagles, Edgar Red pyrogalloladsorption voltammetrycysteaminegold filmRojo de pirogalolvoltamperometría de adsorcióncisteaminapelícula de oroInteraction pyrogallol red (RP) on glassy carbon electrode surface modified gold film (AUF)and cysteamine (cis) was studied. Bearing in mind the order of the modification, it was foundthat the response of oxidation of RP showed higher current to the electrode modified withgold film electro-deposited on cysteamine glassy carbon (GC/Cis /AuF/E), which allowsthe RP oxidation potential of 0.48 V at pH 3.25. Electrochemical devices, such as pH, scanrate (Ʋ), adsorption potential (Eads) and adsorption time (tads) parameters were optimized toyield values: pH 3.25; Ʋ 75.50mV s-1; Eads0.10 V and tads60 s respectively. The calibrationcurve linearity reached a range between 2.00 x 10-7and 15.14x10-7mol L-1. The detection limit(3S/m) was 1.20 x 10-7mol L-1 and relative standard deviation for measurements of sevenequal RP 5.0 x 10-4mol L-1 was 1.01%.Se estudió la interacción del Rojo de Pirogalol (RP) sobre la superficie de un electrodo decarbono vítreo modificado con película de oro (AuF) y cisteamina (cis). Teniendo presente elorden de la modificación, se encontró que la respuesta de oxidación del RP presentó mayorcorriente con el electrodo modificado con cisteamina sobre película de oro electro-depositadasobre carbono vítreo (GC/AuF/Cis/E), el cual permite la oxidación de RP a un potencialde 0,48 V a pH 3,25. Con el método univariable se buscó parámetros óptimos, tales comopH, velocidad de barrido (Ʋ), potencial de adsorción (Eads) y tiempo de adsorción (tads),obteniéndose valores de: pH3,25; Ʋ 75,50mV s-1; Eads0,10 V y tads60 s, respectivamente. Lacurva de calibrado alcanzó un rango de linealidad entre 2,00 x 10-7 y 15,14x10-7 mol L–1. Ellímite de detección (3S/m) fue de 1,20 x 10-7 molL-1 y la desviación estándar relativa parasiete mediciones iguales de RP 5,0 x 10-4 mol L-1 fue de 1,01 %.Sociedad Química del Perú2015-06-30info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontexttextoapplication/pdfhttp://revistas.sqperu.org.pe/index.php/revistasqperu/article/view/2910.37761/rsqp.v81i2.29Revista de la Sociedad Química del Perú; Vol. 81 Núm. 2 (2015): Revistas de la Sociedad Química del Perú; 185 - 192Journal of the Chemical Society of Peru; Vol. 81 No. 2 (2015): Magazine of Sociedad Química del Perú; 185 - 1922309-87401810-634X10.37761/rsqp.v81i2reponame:Revista de la Sociedad Química del Perúinstname:Sociedad Química del Perúinstacron:SQPspahttp://revistas.sqperu.org.pe/index.php/revistasqperu/article/view/29/2420152015Derechos de autor 2015 Sociedad Química del Perúhttps://creativecommons.org/licenses/by/4.0/deed.esinfo:eu-repo/semantics/openAccessoai:rsqp.revistas.sqperu.org.pe:article/292020-03-04T04:23:08Z |
dc.title.none.fl_str_mv |
DETERMINATION OF PYROGALLOL RED ON A GLASSY CARBON ELECTRODE MODIFIED WITH GOLD FILM AND CYSTEAMINE BY ADSORPTION VOLTAMMETRY (AdsV). POSSIBLE USE AS ELECTROCHEMICAL SENSOR DETERMINACIÓN DE ROJO DE PIROGALOL USANDO UN ELECTRODO DE CARBONO VÍTREO MODIFICADO CON PELÍCULA DE ORO Y CISTEAMINA POR VOLTAMPEROMETRÍA DE ADSORCIÓN (AdSV). POSIBLE USO COMO SENSOR ELECTROQUÍMICO |
title |
DETERMINATION OF PYROGALLOL RED ON A GLASSY CARBON ELECTRODE MODIFIED WITH GOLD FILM AND CYSTEAMINE BY ADSORPTION VOLTAMMETRY (AdsV). POSSIBLE USE AS ELECTROCHEMICAL SENSOR |
spellingShingle |
DETERMINATION OF PYROGALLOL RED ON A GLASSY CARBON ELECTRODE MODIFIED WITH GOLD FILM AND CYSTEAMINE BY ADSORPTION VOLTAMMETRY (AdsV). POSSIBLE USE AS ELECTROCHEMICAL SENSOR Bolaños, Karen Red pyrogallol adsorption voltammetry cysteamine gold film Rojo de pirogalol voltamperometría de adsorción cisteamina película de oro |
title_short |
DETERMINATION OF PYROGALLOL RED ON A GLASSY CARBON ELECTRODE MODIFIED WITH GOLD FILM AND CYSTEAMINE BY ADSORPTION VOLTAMMETRY (AdsV). POSSIBLE USE AS ELECTROCHEMICAL SENSOR |
title_full |
DETERMINATION OF PYROGALLOL RED ON A GLASSY CARBON ELECTRODE MODIFIED WITH GOLD FILM AND CYSTEAMINE BY ADSORPTION VOLTAMMETRY (AdsV). POSSIBLE USE AS ELECTROCHEMICAL SENSOR |
title_fullStr |
DETERMINATION OF PYROGALLOL RED ON A GLASSY CARBON ELECTRODE MODIFIED WITH GOLD FILM AND CYSTEAMINE BY ADSORPTION VOLTAMMETRY (AdsV). POSSIBLE USE AS ELECTROCHEMICAL SENSOR |
title_full_unstemmed |
DETERMINATION OF PYROGALLOL RED ON A GLASSY CARBON ELECTRODE MODIFIED WITH GOLD FILM AND CYSTEAMINE BY ADSORPTION VOLTAMMETRY (AdsV). POSSIBLE USE AS ELECTROCHEMICAL SENSOR |
title_sort |
DETERMINATION OF PYROGALLOL RED ON A GLASSY CARBON ELECTRODE MODIFIED WITH GOLD FILM AND CYSTEAMINE BY ADSORPTION VOLTAMMETRY (AdsV). POSSIBLE USE AS ELECTROCHEMICAL SENSOR |
dc.creator.none.fl_str_mv |
Bolaños, Karen Leiva, Yaritza Mariño, Adrián Cuéllar, Claudia Quimbaya, Carolina Castiblanco, Paola Otiniano, Manuel Nagles, Edgar |
author |
Bolaños, Karen |
author_facet |
Bolaños, Karen Leiva, Yaritza Mariño, Adrián Cuéllar, Claudia Quimbaya, Carolina Castiblanco, Paola Otiniano, Manuel Nagles, Edgar |
author_role |
author |
author2 |
Leiva, Yaritza Mariño, Adrián Cuéllar, Claudia Quimbaya, Carolina Castiblanco, Paola Otiniano, Manuel Nagles, Edgar |
author2_role |
author author author author author author author |
dc.subject.none.fl_str_mv |
Red pyrogallol adsorption voltammetry cysteamine gold film Rojo de pirogalol voltamperometría de adsorción cisteamina película de oro |
topic |
Red pyrogallol adsorption voltammetry cysteamine gold film Rojo de pirogalol voltamperometría de adsorción cisteamina película de oro |
description |
Interaction pyrogallol red (RP) on glassy carbon electrode surface modified gold film (AUF)and cysteamine (cis) was studied. Bearing in mind the order of the modification, it was foundthat the response of oxidation of RP showed higher current to the electrode modified withgold film electro-deposited on cysteamine glassy carbon (GC/Cis /AuF/E), which allowsthe RP oxidation potential of 0.48 V at pH 3.25. Electrochemical devices, such as pH, scanrate (Ʋ), adsorption potential (Eads) and adsorption time (tads) parameters were optimized toyield values: pH 3.25; Ʋ 75.50mV s-1; Eads0.10 V and tads60 s respectively. The calibrationcurve linearity reached a range between 2.00 x 10-7and 15.14x10-7mol L-1. The detection limit(3S/m) was 1.20 x 10-7mol L-1 and relative standard deviation for measurements of sevenequal RP 5.0 x 10-4mol L-1 was 1.01%. |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015-06-30 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion text texto |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://revistas.sqperu.org.pe/index.php/revistasqperu/article/view/29 10.37761/rsqp.v81i2.29 |
url |
http://revistas.sqperu.org.pe/index.php/revistasqperu/article/view/29 |
identifier_str_mv |
10.37761/rsqp.v81i2.29 |
dc.language.none.fl_str_mv |
spa |
language |
spa |
dc.relation.none.fl_str_mv |
http://revistas.sqperu.org.pe/index.php/revistasqperu/article/view/29/24 |
dc.rights.none.fl_str_mv |
Derechos de autor 2015 Sociedad Química del Perú https://creativecommons.org/licenses/by/4.0/deed.es info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Derechos de autor 2015 Sociedad Química del Perú https://creativecommons.org/licenses/by/4.0/deed.es |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.coverage.none.fl_str_mv |
2015 2015 |
dc.publisher.none.fl_str_mv |
Sociedad Química del Perú |
publisher.none.fl_str_mv |
Sociedad Química del Perú |
dc.source.none.fl_str_mv |
Revista de la Sociedad Química del Perú; Vol. 81 Núm. 2 (2015): Revistas de la Sociedad Química del Perú; 185 - 192 Journal of the Chemical Society of Peru; Vol. 81 No. 2 (2015): Magazine of Sociedad Química del Perú; 185 - 192 2309-8740 1810-634X 10.37761/rsqp.v81i2 reponame:Revista de la Sociedad Química del Perú instname:Sociedad Química del Perú instacron:SQP |
instname_str |
Sociedad Química del Perú |
instacron_str |
SQP |
institution |
SQP |
reponame_str |
Revista de la Sociedad Química del Perú |
collection |
Revista de la Sociedad Química del Perú |
repository.name.fl_str_mv |
|
repository.mail.fl_str_mv |
|
_version_ |
1842801486896037888 |
score |
12.840276 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).