DETECTION OF AFLATOXINS IN AMBULATORY SAMPLES OF CANNABIS OIL SOLUTION FROM LIMA METROPOLITANA BY FLUORESCENCE LIQUID CHROMATOGRAPHY DETECTOR (FL-HPLC)

Descripción del Articulo

In this study we identified and quantified five samples of oily solutions of cannabis that were collected on an outpatient basis from the center of Lima, Perú, in order to perform the analysis was performed by liquid chromatography with fluorescence detector (HPLC-FL) analysis required a standard co...

Descripción completa

Detalles Bibliográficos
Autores: Castro Luna, Américo, Huachaca Lagos, Daice, Ramos Cevallos, Norma, Castillo Morales, Felix, Zuñiga Santi, Arcadio, Barrientos Amau, Adil, Puma Puma, Maricielo, Otori Querevalu, Sofia
Formato: artículo
Fecha de Publicación:2025
Institución:Sociedad Química del Perú
Repositorio:Revista de la Sociedad Química del Perú
Lenguaje:español
OAI Identifier:oai:rsqp.revistas.sqperu.org.pe:article/509
Enlace del recurso:https://revistas.sqperu.org.pe/index.php/revistasqperu/article/view/509
Nivel de acceso:acceso abierto
Materia:Aflatoxins
Cannabis
Liquid chromatography
Fluorescence
Aflatoxinas
Cromatografía líquida
Fluorescencia
Descripción
Sumario:In this study we identified and quantified five samples of oily solutions of cannabis that were collected on an outpatient basis from the center of Lima, Perú, in order to perform the analysis was performed by liquid chromatography with fluorescence detector (HPLC-FL) analysis required a standard containing a mix of four aflatoxins which are aflatoxins G1, B1, G2 and B2, From the standard aflatoxins of a concentration of 2,6 ug/mL (mix of AFB1, AFB2, AFG1 and AFG2) 1ug/mL of AFB1, 1ug/mL of AFG1, 0. 3 ug/mL of AFB2 and 0.3 ug/mL of AFG2, the results obtained in the analyzed samples do not contain aflatoxins. Quality control is of utmost importance to verify that the formulations with cannabis can have an adequate dose, the adequate dose, contamination by microorganisms, mycotoxins such as aflatoxins, pesticides, among others, must be controlled in order to avoid dangerous consequences for health, safety standards and the respective quality control must be complied with.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).