Objective: To evaluate a Chinese-made carbon-13 breath test as a non-invasive diagnostic method for Hp infection in the Peruvian population through the determination of sensitivity, specificity, positive and negative predictive value, positive and negative likelihood ratio, and diagnostic utility. M...

Descripción completa

Detalles Bibliográficos
Autores: Bernui Vigo, Grazia María, Del Aguila Gamarra, Lorena Alexandra, Sanes Guevara, María Fátima, Prochazka Zarate, Ricardo, Bussalleu Rivera, Alejandro
Formato: artículo
Fecha de Publicación:2022
Institución:Sociedad de Gastroenterología del Perú
Repositorio:Revista de Gastroenterología del Perú
Lenguaje:español
OAI Identifier:oai:ojs.revistagastroperu.com:article/1341
Enlace del recurso:http://www.revistagastroperu.com/index.php/rgp/article/view/1341
Nivel de acceso:acceso abierto
Materia:Breath tests
Helicobacter pylori
Biopsy
Endoscopy
Evaluation study
pruebas respiratorias
gastrointestinal
biopsia
endoscopía
estudio de evaluación
Descripción
Sumario:Objective: To evaluate a Chinese-made carbon-13 breath test as a non-invasive diagnostic method for Hp infection in the Peruvian population through the determination of sensitivity, specificity, positive and negative predictive value, positive and negative likelihood ratio, and diagnostic utility. Materials and methods: A cross-sectional and descriptive study was carried out on a secondary database of the Gastroenterology Service of the Cayetano Heredia Hospital and Cayetano Heredia Clinic from November 2017 to August 2018. Patients over 18 years of age who underwent endoscopy were included upper digestive. Results: A sensitivity of 90.3% (95% CI 0.81-0.96), a specificity of 82.5% (95% CI 0.67-0.93), a positive predictive value was found and negative of 90.3% and 82.5%, and positive and negative likelihood ratio of 5.16 and 0.12, respectively. The area under the ROC curve was 0.88 (95% CI: 0.80-0.96). Conclusions: The carbon 13 breath test is a non-invasive and simple test that provides results quickly. However, it is not possible to recommend the routine use of this test due to the discrepancy between the international and local results obtained. Studies with larger sam d protocols and different manufacturers are suggested to evaluate their performance and characteristics.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).