Ex vivos models to teaching therapeutic endoscopic ultrasound (T-EUS)
Descripción del Articulo
Background: Endoscopic ultrasound training has a learning curve greater than the other endoscopic therapeutic techniques.One of the preclinical teaching methods is the use of ex vivo porcine models. Aim: To describe five ex vivo porcine modelsfor training in therapeutic echoendoscopic procedures. Ma...
| Autores: | , , , , , , |
|---|---|
| Formato: | artículo |
| Fecha de Publicación: | 2018 |
| Institución: | Sociedad de Gastroenterología del Perú |
| Repositorio: | Revista de Gastroenterología del Perú |
| Lenguaje: | español |
| OAI Identifier: | oai:ojs.revistagastroperu.com:article/877 |
| Enlace del recurso: | http://www.revistagastroperu.com/index.php/rgp/article/view/877 |
| Nivel de acceso: | acceso abierto |
| Materia: | Endoscopic ultrasonography Simulation training Learning curve |
| id |
REVSGP_31f55c14dbc0bbf15f058700aba73444 |
|---|---|
| oai_identifier_str |
oai:ojs.revistagastroperu.com:article/877 |
| network_acronym_str |
REVSGP |
| network_name_str |
Revista de Gastroenterología del Perú |
| repository_id_str |
. |
| spelling |
Ex vivos models to teaching therapeutic endoscopic ultrasound (T-EUS)L.A. Artifon, EversonCheng, SpencerThaisa Nakadomari, ThaisaKashiwagi, LeandroCelso Ardengh, JoseBelmonte, EmilioOtoch, Jose P.Endoscopic ultrasonographySimulation trainingLearning curveBackground: Endoscopic ultrasound training has a learning curve greater than the other endoscopic therapeutic techniques.One of the preclinical teaching methods is the use of ex vivo porcine models. Aim: To describe five ex vivo porcine modelsfor training in therapeutic echoendoscopic procedures. Materials and methods: Using porcine digestive tract containingesophagus, stomach, duodenum, spleen, liver and gallbladder, five models for therapeutic echoendoscopy training weredescribed. With other segments of the porcine pieces (such as the bladder, spleen segment and omentum segment) andwith easily accessible materials (such as grape and ultrasound gel), lesions were simulated to be treated. These models wereapplied in the Hands on course at the IRCAD (Institut de recherche contre les cancers de l'appareil digestif) Barretos of2017. Endoscopic equipment and instruments are the same as those used in clinical practice. Result: The models are easilyreproducible and do not require exchange during the hands on course period. Endoscopic and echographic imaging andtactile sensitivity are similar to the real one. Conclusion: The models described in this study demonstrated to be realistic,easy to reproduce and allow repetition during the same session. However, comparative studies are necessary to verify thereal impact on teaching.Sociedad de Gastroenterología del Perú2018-05-15info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://www.revistagastroperu.com/index.php/rgp/article/view/87710.47892/rgp.2018.381.877Revista de Gastroenterología del Perú; Vol. 38 Núm. 1 (2018); 103-1101609-722X1022-5129reponame:Revista de Gastroenterología del Perúinstname:Sociedad de Gastroenterología del Perúinstacron:SOCIOGASTROspahttp://www.revistagastroperu.com/index.php/rgp/article/view/877/851Derechos de autor 2018 Revista de Gastroenterología del Perúinfo:eu-repo/semantics/openAccessoai:ojs.revistagastroperu.com:article/8772018-05-15T19:54:34Z |
| dc.title.none.fl_str_mv |
Ex vivos models to teaching therapeutic endoscopic ultrasound (T-EUS) |
| title |
Ex vivos models to teaching therapeutic endoscopic ultrasound (T-EUS) |
| spellingShingle |
Ex vivos models to teaching therapeutic endoscopic ultrasound (T-EUS) L.A. Artifon, Everson Endoscopic ultrasonography Simulation training Learning curve |
| title_short |
Ex vivos models to teaching therapeutic endoscopic ultrasound (T-EUS) |
| title_full |
Ex vivos models to teaching therapeutic endoscopic ultrasound (T-EUS) |
| title_fullStr |
Ex vivos models to teaching therapeutic endoscopic ultrasound (T-EUS) |
| title_full_unstemmed |
Ex vivos models to teaching therapeutic endoscopic ultrasound (T-EUS) |
| title_sort |
Ex vivos models to teaching therapeutic endoscopic ultrasound (T-EUS) |
| dc.creator.none.fl_str_mv |
L.A. Artifon, Everson Cheng, Spencer Thaisa Nakadomari, Thaisa Kashiwagi, Leandro Celso Ardengh, Jose Belmonte, Emilio Otoch, Jose P. |
| author |
L.A. Artifon, Everson |
| author_facet |
L.A. Artifon, Everson Cheng, Spencer Thaisa Nakadomari, Thaisa Kashiwagi, Leandro Celso Ardengh, Jose Belmonte, Emilio Otoch, Jose P. |
| author_role |
author |
| author2 |
Cheng, Spencer Thaisa Nakadomari, Thaisa Kashiwagi, Leandro Celso Ardengh, Jose Belmonte, Emilio Otoch, Jose P. |
| author2_role |
author author author author author author |
| dc.subject.none.fl_str_mv |
Endoscopic ultrasonography Simulation training Learning curve |
| topic |
Endoscopic ultrasonography Simulation training Learning curve |
| description |
Background: Endoscopic ultrasound training has a learning curve greater than the other endoscopic therapeutic techniques.One of the preclinical teaching methods is the use of ex vivo porcine models. Aim: To describe five ex vivo porcine modelsfor training in therapeutic echoendoscopic procedures. Materials and methods: Using porcine digestive tract containingesophagus, stomach, duodenum, spleen, liver and gallbladder, five models for therapeutic echoendoscopy training weredescribed. With other segments of the porcine pieces (such as the bladder, spleen segment and omentum segment) andwith easily accessible materials (such as grape and ultrasound gel), lesions were simulated to be treated. These models wereapplied in the Hands on course at the IRCAD (Institut de recherche contre les cancers de l'appareil digestif) Barretos of2017. Endoscopic equipment and instruments are the same as those used in clinical practice. Result: The models are easilyreproducible and do not require exchange during the hands on course period. Endoscopic and echographic imaging andtactile sensitivity are similar to the real one. Conclusion: The models described in this study demonstrated to be realistic,easy to reproduce and allow repetition during the same session. However, comparative studies are necessary to verify thereal impact on teaching. |
| publishDate |
2018 |
| dc.date.none.fl_str_mv |
2018-05-15 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
http://www.revistagastroperu.com/index.php/rgp/article/view/877 10.47892/rgp.2018.381.877 |
| url |
http://www.revistagastroperu.com/index.php/rgp/article/view/877 |
| identifier_str_mv |
10.47892/rgp.2018.381.877 |
| dc.language.none.fl_str_mv |
spa |
| language |
spa |
| dc.relation.none.fl_str_mv |
http://www.revistagastroperu.com/index.php/rgp/article/view/877/851 |
| dc.rights.none.fl_str_mv |
Derechos de autor 2018 Revista de Gastroenterología del Perú info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
Derechos de autor 2018 Revista de Gastroenterología del Perú |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Sociedad de Gastroenterología del Perú |
| publisher.none.fl_str_mv |
Sociedad de Gastroenterología del Perú |
| dc.source.none.fl_str_mv |
Revista de Gastroenterología del Perú; Vol. 38 Núm. 1 (2018); 103-110 1609-722X 1022-5129 reponame:Revista de Gastroenterología del Perú instname:Sociedad de Gastroenterología del Perú instacron:SOCIOGASTRO |
| instname_str |
Sociedad de Gastroenterología del Perú |
| instacron_str |
SOCIOGASTRO |
| institution |
SOCIOGASTRO |
| reponame_str |
Revista de Gastroenterología del Perú |
| collection |
Revista de Gastroenterología del Perú |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1846699730775572480 |
| score |
13.046471 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).