Evaluation and design of protection against hydraulic scouring of the Unocolla bridge, Juliaca - Puno
Descripción del Articulo
In general, when the river flow increases, a scour phenomenon will occur, in which the substructure of the bridge, be it abutment and / or piers, will be affected, resulting in a partial or total collapse of the structure. All of the above is the key to achieving our research objectives, which is to...
Autores: | , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2022 |
Institución: | Universidad Nacional Autónoma de Tayacaja Daniel Hernández Morillo |
Repositorio: | Revista de investigación científica y tecnológica Llamkasun |
Lenguaje: | español |
OAI Identifier: | oai:ojs2.llamkasun.unat.edu.pe:article/85 |
Enlace del recurso: | https://llamkasun.unat.edu.pe/index.php/revista/article/view/85 |
Nivel de acceso: | acceso abierto |
Materia: | socavación puente modelamiento enrocado scouring bridging shaping castling minando ponte modelagem enrocamento |
Sumario: | In general, when the river flow increases, a scour phenomenon will occur, in which the substructure of the bridge, be it abutment and / or piers, will be affected, resulting in a partial or total collapse of the structure. All of the above is the key to achieving our research objectives, which is to carry out an evaluation and protection design against the hydraulic scour process of the Unocolla bridge in the city of Juliaca, Puno. The population will be the Unocolla bridge and the sample will be a substructure of the bridge. The method used is applied and its design is pure experimental, using quantitative methods, in which the research problem is described as realistic results. To determine the scour effects, topographic, hydrological and sedimentological information was collected to later carry out hydraulic modeling in the Hec-Ras program. Scour depths were determined in reference to pillars, determining in pillar 1 scour depth 1.2 m, in pillar 2 scour depth 2.46 m, in pillar 3 scour depth 1.2 m, in pillar 4 scour depth 1.2 m , for which the castling process is proposed as an alternative solution. |
---|
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).