Medical devices in times of pandemic: Efficacy of a high-flow artisanal system in the management of patients hospitalized by COVID-19.
Descripción del Articulo
Objective: To evaluate the efficacy of the Wayrachi continuous positive airway pressure (CPAP) non-invasive respiratory support device compared to the commercial high-flow cannula (CAF) for the treatment of patients with SARS-CoV-2. Methods: Study carried out at the Honorio Delgado Espinoza Hospital...
Autores: | , , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2023 |
Institución: | Colegio Médico del Perú |
Repositorio: | Acta Médica Peruana |
Lenguaje: | español |
OAI Identifier: | oai:amp.cmp.org.pe:article/2712 |
Enlace del recurso: | https://amp.cmp.org.pe/index.php/AMP/article/view/2712 |
Nivel de acceso: | acceso abierto |
Materia: | Dispositivo Médico Tratamiento Conservador Ventilación no Invasiva COVID-19 Medical Device Conservative Treatment Noninvasive Ventilation Covid-19 |
id |
REVCMP_3e55b748ef54d9b1c75d39203ca90cd2 |
---|---|
oai_identifier_str |
oai:amp.cmp.org.pe:article/2712 |
network_acronym_str |
REVCMP |
network_name_str |
Acta Médica Peruana |
repository_id_str |
. |
spelling |
Medical devices in times of pandemic: Efficacy of a high-flow artisanal system in the management of patients hospitalized by COVID-19.Dispositivos médicos en tiempos de pandemia: Eficacia de un sistema artesanal de alto flujo en el manejo de pacientes hospitalizados por COVID-19Muñoz del Carpio Toia, AguedaLópez Ticona, AldoOsada, JorgeMuñoz del Carpio Toia, AguedaLópez Ticona, AldoOsada, JorgeDispositivo MédicoTratamiento ConservadorVentilación no InvasivaCOVID-19Medical DeviceConservative TreatmentNoninvasive VentilationCovid-19Objective: To evaluate the efficacy of the Wayrachi continuous positive airway pressure (CPAP) non-invasive respiratory support device compared to the commercial high-flow cannula (CAF) for the treatment of patients with SARS-CoV-2. Methods: Study carried out at the Honorio Delgado Espinoza Hospital in Arequipa (Hospital COVID-MINSA Arequipa). The medical records of patients with SARS-CoV-2, of moderate or severe severity, who required non-invasive respiratory assistance, hospitalized in the internal medicine service during the 2nd wave of COVID in Peru, were evaluated. A survival analysis was performed considering days to death comparing Wayrachi with CAF. The effect of variables on death was explored using Cox regression. Results: 114 patients treated with Wayrachi (56.44%) and 88 with CAF (43.5%) were evaluated, observing a frequency of death of 34.2% and 34.1%, respectively. When comparing the frequency of death, or its survival, in both managements, no significant difference was observed (p=0.986 and p=0.928), this was maintained in the multivariate model. Conclusion: The Wayrachi CPAP had similar results to those presented by the commercial CAF equipment, which indicates it as an effective option for the management of COVID patients who require non-invasive respiratory support.Objetivo: Evaluar la eficacia del dispositivo artesanal de asistencia respiratoria no invasivo de administración de presión positiva continua en las vías respiratorias (CPAP) Wayrachi en comparación con la cánula de alto flujo comercial (CAF) para el tratamiento de pacientes con SARS-CoV-2. Métodos: Estudio realizado en el Hospital Honorio Delgado Espinoza de Arequipa (Hospital COVID-MINSA Arequipa). Se evaluó a las historias clínicas de pacientes con SARS-CoV-2, de severidad moderada o grave que requerían asistencia respiratoria no invasiva, hospitalizados en el servicio de medicina interna durante la 2da ola de COVID en el Perú. Se realizó un análisis de supervivencia considerando los días a la muerte comparando al Wayrachi con la CAF. Se exploró el efecto de las variables sobre la muerte mediante una regresión de Cox. Resultados: Se evaluaron 114 pacientes tratados con Wayrachi (56,44%) y 88 con CAF (43,5%), observándose una frecuencia de muerte de 34,2% y 34,1% respectivamente. Al comparar la frecuencia de muerte, o su sobrevida, en ambos manejos no se observó una diferencia significativa (p=0,986 y p=0,928), esto se mantuvo en el modelo multivariado. Conclusión: El CPAP Wayrachi tuvo resultados similares a los presentados por el equipo CAF comercial lo que lo indica como una opción eficaz para el manejo de pacientes COVID que requieran soporte respiratorio no invasivo.Colegio Médico del Perú2023-12-04info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdftext/htmltext/xmlhttps://amp.cmp.org.pe/index.php/AMP/article/view/271210.35663/amp.2023.403.2712ACTA MEDICA PERUANA; Vol. 40 No. 3 (2023): July - SeptemberACTA MEDICA PERUANA; Vol. 40 Núm. 3 (2023): Julio - Setiembre1728-59171018-8800reponame:Acta Médica Peruanainstname:Colegio Médico del Perúinstacron:CMPspahttps://amp.cmp.org.pe/index.php/AMP/article/view/2712/1576https://amp.cmp.org.pe/index.php/AMP/article/view/2712/1712https://amp.cmp.org.pe/index.php/AMP/article/view/2712/1713Copyright (c) 2023 ACTA MEDICA PERUANAinfo:eu-repo/semantics/openAccessoai:amp.cmp.org.pe:article/27122024-10-02T04:18:21Z |
dc.title.none.fl_str_mv |
Medical devices in times of pandemic: Efficacy of a high-flow artisanal system in the management of patients hospitalized by COVID-19. Dispositivos médicos en tiempos de pandemia: Eficacia de un sistema artesanal de alto flujo en el manejo de pacientes hospitalizados por COVID-19 |
title |
Medical devices in times of pandemic: Efficacy of a high-flow artisanal system in the management of patients hospitalized by COVID-19. |
spellingShingle |
Medical devices in times of pandemic: Efficacy of a high-flow artisanal system in the management of patients hospitalized by COVID-19. Muñoz del Carpio Toia, Agueda Dispositivo Médico Tratamiento Conservador Ventilación no Invasiva COVID-19 Medical Device Conservative Treatment Noninvasive Ventilation Covid-19 |
title_short |
Medical devices in times of pandemic: Efficacy of a high-flow artisanal system in the management of patients hospitalized by COVID-19. |
title_full |
Medical devices in times of pandemic: Efficacy of a high-flow artisanal system in the management of patients hospitalized by COVID-19. |
title_fullStr |
Medical devices in times of pandemic: Efficacy of a high-flow artisanal system in the management of patients hospitalized by COVID-19. |
title_full_unstemmed |
Medical devices in times of pandemic: Efficacy of a high-flow artisanal system in the management of patients hospitalized by COVID-19. |
title_sort |
Medical devices in times of pandemic: Efficacy of a high-flow artisanal system in the management of patients hospitalized by COVID-19. |
dc.creator.none.fl_str_mv |
Muñoz del Carpio Toia, Agueda López Ticona, Aldo Osada, Jorge Muñoz del Carpio Toia, Agueda López Ticona, Aldo Osada, Jorge |
author |
Muñoz del Carpio Toia, Agueda |
author_facet |
Muñoz del Carpio Toia, Agueda López Ticona, Aldo Osada, Jorge |
author_role |
author |
author2 |
López Ticona, Aldo Osada, Jorge |
author2_role |
author author |
dc.subject.none.fl_str_mv |
Dispositivo Médico Tratamiento Conservador Ventilación no Invasiva COVID-19 Medical Device Conservative Treatment Noninvasive Ventilation Covid-19 |
topic |
Dispositivo Médico Tratamiento Conservador Ventilación no Invasiva COVID-19 Medical Device Conservative Treatment Noninvasive Ventilation Covid-19 |
description |
Objective: To evaluate the efficacy of the Wayrachi continuous positive airway pressure (CPAP) non-invasive respiratory support device compared to the commercial high-flow cannula (CAF) for the treatment of patients with SARS-CoV-2. Methods: Study carried out at the Honorio Delgado Espinoza Hospital in Arequipa (Hospital COVID-MINSA Arequipa). The medical records of patients with SARS-CoV-2, of moderate or severe severity, who required non-invasive respiratory assistance, hospitalized in the internal medicine service during the 2nd wave of COVID in Peru, were evaluated. A survival analysis was performed considering days to death comparing Wayrachi with CAF. The effect of variables on death was explored using Cox regression. Results: 114 patients treated with Wayrachi (56.44%) and 88 with CAF (43.5%) were evaluated, observing a frequency of death of 34.2% and 34.1%, respectively. When comparing the frequency of death, or its survival, in both managements, no significant difference was observed (p=0.986 and p=0.928), this was maintained in the multivariate model. Conclusion: The Wayrachi CPAP had similar results to those presented by the commercial CAF equipment, which indicates it as an effective option for the management of COVID patients who require non-invasive respiratory support. |
publishDate |
2023 |
dc.date.none.fl_str_mv |
2023-12-04 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
https://amp.cmp.org.pe/index.php/AMP/article/view/2712 10.35663/amp.2023.403.2712 |
url |
https://amp.cmp.org.pe/index.php/AMP/article/view/2712 |
identifier_str_mv |
10.35663/amp.2023.403.2712 |
dc.language.none.fl_str_mv |
spa |
language |
spa |
dc.relation.none.fl_str_mv |
https://amp.cmp.org.pe/index.php/AMP/article/view/2712/1576 https://amp.cmp.org.pe/index.php/AMP/article/view/2712/1712 https://amp.cmp.org.pe/index.php/AMP/article/view/2712/1713 |
dc.rights.none.fl_str_mv |
Copyright (c) 2023 ACTA MEDICA PERUANA info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Copyright (c) 2023 ACTA MEDICA PERUANA |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf text/html text/xml |
dc.publisher.none.fl_str_mv |
Colegio Médico del Perú |
publisher.none.fl_str_mv |
Colegio Médico del Perú |
dc.source.none.fl_str_mv |
ACTA MEDICA PERUANA; Vol. 40 No. 3 (2023): July - September ACTA MEDICA PERUANA; Vol. 40 Núm. 3 (2023): Julio - Setiembre 1728-5917 1018-8800 reponame:Acta Médica Peruana instname:Colegio Médico del Perú instacron:CMP |
instname_str |
Colegio Médico del Perú |
instacron_str |
CMP |
institution |
CMP |
reponame_str |
Acta Médica Peruana |
collection |
Acta Médica Peruana |
repository.name.fl_str_mv |
|
repository.mail.fl_str_mv |
|
_version_ |
1842710634480795648 |
score |
13.10263 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).