Sentinel lymph node biopsy with blue patent more imprinted in the axillary stage of breast cancer in a hospital of high complexity

Descripción del Articulo

Objetive: To analyze the main clinical-pathological characteristics of patients with breast carcinoma in whom a sentinel lymph node biopsy was performed with patent blue plus imprint in the axillary staging. The study. This descriptive series evaluated a series of 20 cases of patients with an anatom...

Descripción completa

Detalles Bibliográficos
Autores: Yan-Quiroz, Edgar Fermin, Agreda–Castro, Folker, Loayza-Silva, Carmen Carolina, Nuñez-Pachec, Renzo, Chu-Ramírez, Carlos
Formato: artículo
Fecha de Publicación:2021
Institución:Cuerpo Médico Hospital Nacional Almanzor Aguinaga Asenjo
Repositorio:Revista del Cuerpo Médico Hospital Nacional Almanzor Aguinaga Asenjo
Lenguaje:español
OAI Identifier:oai:cmhnaaa_ojs_cmhnaaa.cmhnaaa.org.pe:article/1064
Enlace del recurso:https://cmhnaaa.org.pe/ojs/index.php/rcmhnaaa/article/view/1064
Nivel de acceso:acceso abierto
Materia:Ganglio centinela
Impronta Molecular
Cáncer de mama
Neoplasias
Biopsia
Servicio de Oncología en Hospital
Sentinel lymph node
Imprint
Breast cancer
Neoplasms
Biopsy
Oncology Service
Hospital
id REVCMH_5a42dac5c9e254d8c61cef0ef2f67ca3
oai_identifier_str oai:cmhnaaa_ojs_cmhnaaa.cmhnaaa.org.pe:article/1064
network_acronym_str REVCMH
network_name_str Revista del Cuerpo Médico Hospital Nacional Almanzor Aguinaga Asenjo
repository_id_str
spelling Sentinel lymph node biopsy with blue patent more imprinted in the axillary stage of breast cancer in a hospital of high complexityBiopsia de ganglio centinela con azul patente más impronta en el estadiaje axilar de cáncer de mama en un hospital de alta complejidadYan-Quiroz, Edgar FerminAgreda–Castro, FolkerLoayza-Silva, Carmen CarolinaNuñez-Pachec, RenzoChu-Ramírez, CarlosGanglio centinelaImpronta MolecularCáncer de mamaNeoplasiasBiopsiaServicio de Oncología en HospitalSentinel lymph nodeImprintBreast cancerNeoplasmsBiopsyOncology ServiceHospitalObjetive: To analyze the main clinical-pathological characteristics of patients with breast carcinoma in whom a sentinel lymph node biopsy was performed with patent blue plus imprint in the axillary staging. The study. This descriptive series evaluated a series of 20 cases of patients with an anatomopathological diagnosis of infiltrating ductal carcinoma treated in the area of ​​Oncological Surgery of the Hospital of High Complexity "Virgen de la Puerta" EsSalud, La Libertad - Peru, during the period February 2017 until January 2018. Findings: The sensitivity and specificity of the sentinel lymph node imprint was 75% respectively. The positive and negative predictive value was 67% and 82% respectively. The positive and negative likelihood ratio was 3.0 and 0.33. The Kappa index was 0.2 of considered as a concordance index. Conclusions. The sentinel lymph node technique is a good alternative for the management of breast cancer, since it avoids unnecessary surgical interventions.Objetivo: Analizar las principales características clínicopatológicas de pacientes con carcinoma de mama en quienes se realizó biopsia de ganglio centinela con azul patente más impronta en el estadiaje axilar. El estudio. Serie descriptiva, evaluó una serie de 20 casos con diagnóstico anatomopatológico de carcinoma ductal infiltrante atendidas en el área de Cirugía Oncológica del Hospital de Alta Complejidad “Virgen de la Puerta” EsSalud, La Libertad - Perú, durante el periodo febrero 2017 - enero 2018. Hallazgos: La sensibilidad y especificidad de la impronta de ganglio centinela fue de 75% respectivamente. El valor predictivo positivo y negativo fue de 67% y 82%. El cociente de probabilidad positivo y negativo fue de 3,0 y 0,33. El índice de Kappa fue 0,2 de considerado como un índice de concordancia. Conclusiones: La técnica del ganglio centinela es una buena alternativa para el manejo de cáncer de mama, ya que evita intervenciones quirúrgicas innecesarias.Cuerpo Médico del Hospital Nacional Almanzor Aguinaga Asenjo2021-09-04info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://cmhnaaa.org.pe/ojs/index.php/rcmhnaaa/article/view/106410.35434/rcmhnaaa.2021.142.1064Revista del Cuerpo Médico Hospital Nacional Almanzor Aguinaga Asenjo; Vol. 14 No. 2 (2021): April - June; 190 - 194Revista del Cuerpo Médico Hospital Nacional Almanzor Aguinaga Asenjo; Vol. 14 Núm. 2 (2021): Abril - Junio; 190 - 1942227-47312225-5109reponame:Revista del Cuerpo Médico Hospital Nacional Almanzor Aguinaga Asenjoinstname:Cuerpo Médico Hospital Nacional Almanzor Aguinaga Asenjoinstacron:HNAAAspahttps://cmhnaaa.org.pe/ojs/index.php/rcmhnaaa/article/view/1064/434Derechos de autor 2021 Edgar Fermin Yan-Quiroz, Folker Agreda–Castro, Carmen Carolina Loayza-Silva, Renzo Nuñez-Pachec, Carlos Chu-Ramírezinfo:eu-repo/semantics/openAccessoai:cmhnaaa_ojs_cmhnaaa.cmhnaaa.org.pe:article/10642022-02-01T00:20:36Z
dc.title.none.fl_str_mv Sentinel lymph node biopsy with blue patent more imprinted in the axillary stage of breast cancer in a hospital of high complexity
Biopsia de ganglio centinela con azul patente más impronta en el estadiaje axilar de cáncer de mama en un hospital de alta complejidad
title Sentinel lymph node biopsy with blue patent more imprinted in the axillary stage of breast cancer in a hospital of high complexity
spellingShingle Sentinel lymph node biopsy with blue patent more imprinted in the axillary stage of breast cancer in a hospital of high complexity
Yan-Quiroz, Edgar Fermin
Ganglio centinela
Impronta Molecular
Cáncer de mama
Neoplasias
Biopsia
Servicio de Oncología en Hospital
Sentinel lymph node
Imprint
Breast cancer
Neoplasms
Biopsy
Oncology Service
Hospital
title_short Sentinel lymph node biopsy with blue patent more imprinted in the axillary stage of breast cancer in a hospital of high complexity
title_full Sentinel lymph node biopsy with blue patent more imprinted in the axillary stage of breast cancer in a hospital of high complexity
title_fullStr Sentinel lymph node biopsy with blue patent more imprinted in the axillary stage of breast cancer in a hospital of high complexity
title_full_unstemmed Sentinel lymph node biopsy with blue patent more imprinted in the axillary stage of breast cancer in a hospital of high complexity
title_sort Sentinel lymph node biopsy with blue patent more imprinted in the axillary stage of breast cancer in a hospital of high complexity
dc.creator.none.fl_str_mv Yan-Quiroz, Edgar Fermin
Agreda–Castro, Folker
Loayza-Silva, Carmen Carolina
Nuñez-Pachec, Renzo
Chu-Ramírez, Carlos
author Yan-Quiroz, Edgar Fermin
author_facet Yan-Quiroz, Edgar Fermin
Agreda–Castro, Folker
Loayza-Silva, Carmen Carolina
Nuñez-Pachec, Renzo
Chu-Ramírez, Carlos
author_role author
author2 Agreda–Castro, Folker
Loayza-Silva, Carmen Carolina
Nuñez-Pachec, Renzo
Chu-Ramírez, Carlos
author2_role author
author
author
author
dc.subject.none.fl_str_mv Ganglio centinela
Impronta Molecular
Cáncer de mama
Neoplasias
Biopsia
Servicio de Oncología en Hospital
Sentinel lymph node
Imprint
Breast cancer
Neoplasms
Biopsy
Oncology Service
Hospital
topic Ganglio centinela
Impronta Molecular
Cáncer de mama
Neoplasias
Biopsia
Servicio de Oncología en Hospital
Sentinel lymph node
Imprint
Breast cancer
Neoplasms
Biopsy
Oncology Service
Hospital
description Objetive: To analyze the main clinical-pathological characteristics of patients with breast carcinoma in whom a sentinel lymph node biopsy was performed with patent blue plus imprint in the axillary staging. The study. This descriptive series evaluated a series of 20 cases of patients with an anatomopathological diagnosis of infiltrating ductal carcinoma treated in the area of ​​Oncological Surgery of the Hospital of High Complexity "Virgen de la Puerta" EsSalud, La Libertad - Peru, during the period February 2017 until January 2018. Findings: The sensitivity and specificity of the sentinel lymph node imprint was 75% respectively. The positive and negative predictive value was 67% and 82% respectively. The positive and negative likelihood ratio was 3.0 and 0.33. The Kappa index was 0.2 of considered as a concordance index. Conclusions. The sentinel lymph node technique is a good alternative for the management of breast cancer, since it avoids unnecessary surgical interventions.
publishDate 2021
dc.date.none.fl_str_mv 2021-09-04
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://cmhnaaa.org.pe/ojs/index.php/rcmhnaaa/article/view/1064
10.35434/rcmhnaaa.2021.142.1064
url https://cmhnaaa.org.pe/ojs/index.php/rcmhnaaa/article/view/1064
identifier_str_mv 10.35434/rcmhnaaa.2021.142.1064
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv https://cmhnaaa.org.pe/ojs/index.php/rcmhnaaa/article/view/1064/434
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Cuerpo Médico del Hospital Nacional Almanzor Aguinaga Asenjo
publisher.none.fl_str_mv Cuerpo Médico del Hospital Nacional Almanzor Aguinaga Asenjo
dc.source.none.fl_str_mv Revista del Cuerpo Médico Hospital Nacional Almanzor Aguinaga Asenjo; Vol. 14 No. 2 (2021): April - June; 190 - 194
Revista del Cuerpo Médico Hospital Nacional Almanzor Aguinaga Asenjo; Vol. 14 Núm. 2 (2021): Abril - Junio; 190 - 194
2227-4731
2225-5109
reponame:Revista del Cuerpo Médico Hospital Nacional Almanzor Aguinaga Asenjo
instname:Cuerpo Médico Hospital Nacional Almanzor Aguinaga Asenjo
instacron:HNAAA
instname_str Cuerpo Médico Hospital Nacional Almanzor Aguinaga Asenjo
instacron_str HNAAA
institution HNAAA
reponame_str Revista del Cuerpo Médico Hospital Nacional Almanzor Aguinaga Asenjo
collection Revista del Cuerpo Médico Hospital Nacional Almanzor Aguinaga Asenjo
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1843263927405772800
score 12.650644
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).