Sensors based on porous Pd-doped hematite (alpha-Fe2O3) for LPG detection
Descripción del Articulo
371-2012-CONCYTEC-OAJ
Autores: | , , , , , , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2014 |
Institución: | Consejo Nacional de Ciencia Tecnología e Innovación |
Repositorio: | CONCYTEC-Institucional |
Lenguaje: | inglés |
OAI Identifier: | oai:repositorio.concytec.gob.pe:20.500.12390/1261 |
Enlace del recurso: | https://hdl.handle.net/20.500.12390/1261 https://doi.org/10.1016/j.micromeso.2013.11.014 |
Nivel de acceso: | acceso abierto |
Materia: | LPG detection Gas sensor https://purl.org/pe-repo/ocde/ford#2.10.00 |
id |
CONC_ada537978df0d1ca452b2c6592b6d1f5 |
---|---|
oai_identifier_str |
oai:repositorio.concytec.gob.pe:20.500.12390/1261 |
network_acronym_str |
CONC |
network_name_str |
CONCYTEC-Institucional |
repository_id_str |
4689 |
spelling |
Publicationrp02497500rp03655600rp02496500rp01220500rp01082500rp02499500rp02498500Picasso, GKou, MRSVargasmachuca, ORojas, JZavala, CLopez, AIrusta, S2024-05-30T23:13:38Z2024-05-30T23:13:38Z2014https://hdl.handle.net/20.500.12390/1261https://doi.org/10.1016/j.micromeso.2013.11.014330930400010371-2012-CONCYTEC-OAJIn this work, sensors based on nanoparticles of α-Fe2O3 doped with different amounts of Pd ranging from 0.1 to 1.0 wt.% were prepared by coprecipitation for liquefied petroleum gas (LPG) detection. Solids were characterized by thermogravimetric and differential thermal analysis (TG–DTA), X-ray diffraction (XRD), adsorption–desorption of N2 (BET surface), transmission electron microscopy (TEM) and X-ray photoelectron spectroscopy (XPS).Consejo Nacional de Ciencia, Tecnología e Innovación Tecnológica - ConcytecengElsevierMicroporous and Mesoporous Materialsinfo:eu-repo/semantics/openAccessLPG detectionGas sensor-1https://purl.org/pe-repo/ocde/ford#2.10.00-1Sensors based on porous Pd-doped hematite (alpha-Fe2O3) for LPG detectioninfo:eu-repo/semantics/articlereponame:CONCYTEC-Institucionalinstname:Consejo Nacional de Ciencia Tecnología e Innovacióninstacron:CONCYTEC#PLACEHOLDER_PARENT_METADATA_VALUE##PLACEHOLDER_PARENT_METADATA_VALUE#20.500.12390/1261oai:repositorio.concytec.gob.pe:20.500.12390/12612024-05-30 15:52:12.643http://purl.org/coar/access_right/c_14cbinfo:eu-repo/semantics/closedAccessmetadata only accesshttps://repositorio.concytec.gob.peRepositorio Institucional CONCYTECrepositorio@concytec.gob.pe#PLACEHOLDER_PARENT_METADATA_VALUE##PLACEHOLDER_PARENT_METADATA_VALUE##PLACEHOLDER_PARENT_METADATA_VALUE##PLACEHOLDER_PARENT_METADATA_VALUE##PLACEHOLDER_PARENT_METADATA_VALUE##PLACEHOLDER_PARENT_METADATA_VALUE##PLACEHOLDER_PARENT_METADATA_VALUE#<Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="53e6bf43-b6ca-4ec0-9838-b6148e583a43"> <Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843</Type> <Language>eng</Language> <Title>Sensors based on porous Pd-doped hematite (alpha-Fe2O3) for LPG detection</Title> <PublishedIn> <Publication> <Title>Microporous and Mesoporous Materials</Title> </Publication> </PublishedIn> <PublicationDate>2014</PublicationDate> <DOI>https://doi.org/10.1016/j.micromeso.2013.11.014</DOI> <ISI-Number>330930400010</ISI-Number> <Authors> <Author> <DisplayName>Picasso, G</DisplayName> <Person id="rp02497" /> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> <Author> <DisplayName>Kou, MRS</DisplayName> <Person id="rp03655" /> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> <Author> <DisplayName>Vargasmachuca, O</DisplayName> <Person id="rp02496" /> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> <Author> <DisplayName>Rojas, J</DisplayName> <Person id="rp01220" /> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> <Author> <DisplayName>Zavala, C</DisplayName> <Person id="rp01082" /> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> <Author> <DisplayName>Lopez, A</DisplayName> <Person id="rp02499" /> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> <Author> <DisplayName>Irusta, S</DisplayName> <Person id="rp02498" /> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Elsevier</DisplayName> <OrgUnit /> </Publisher> </Publishers> <Keyword>LPG detection</Keyword> <Keyword>Gas sensor</Keyword> <Abstract>In this work, sensors based on nanoparticles of α-Fe2O3 doped with different amounts of Pd ranging from 0.1 to 1.0 wt.% were prepared by coprecipitation for liquefied petroleum gas (LPG) detection. Solids were characterized by thermogravimetric and differential thermal analysis (TG–DTA), X-ray diffraction (XRD), adsorption–desorption of N2 (BET surface), transmission electron microscopy (TEM) and X-ray photoelectron spectroscopy (XPS).</Abstract> <Access xmlns="http://purl.org/coar/access_right" > </Access> </Publication> -1 |
dc.title.none.fl_str_mv |
Sensors based on porous Pd-doped hematite (alpha-Fe2O3) for LPG detection |
title |
Sensors based on porous Pd-doped hematite (alpha-Fe2O3) for LPG detection |
spellingShingle |
Sensors based on porous Pd-doped hematite (alpha-Fe2O3) for LPG detection Picasso, G LPG detection Gas sensor https://purl.org/pe-repo/ocde/ford#2.10.00 |
title_short |
Sensors based on porous Pd-doped hematite (alpha-Fe2O3) for LPG detection |
title_full |
Sensors based on porous Pd-doped hematite (alpha-Fe2O3) for LPG detection |
title_fullStr |
Sensors based on porous Pd-doped hematite (alpha-Fe2O3) for LPG detection |
title_full_unstemmed |
Sensors based on porous Pd-doped hematite (alpha-Fe2O3) for LPG detection |
title_sort |
Sensors based on porous Pd-doped hematite (alpha-Fe2O3) for LPG detection |
author |
Picasso, G |
author_facet |
Picasso, G Kou, MRS Vargasmachuca, O Rojas, J Zavala, C Lopez, A Irusta, S |
author_role |
author |
author2 |
Kou, MRS Vargasmachuca, O Rojas, J Zavala, C Lopez, A Irusta, S |
author2_role |
author author author author author author |
dc.contributor.author.fl_str_mv |
Picasso, G Kou, MRS Vargasmachuca, O Rojas, J Zavala, C Lopez, A Irusta, S |
dc.subject.none.fl_str_mv |
LPG detection |
topic |
LPG detection Gas sensor https://purl.org/pe-repo/ocde/ford#2.10.00 |
dc.subject.es_PE.fl_str_mv |
Gas sensor |
dc.subject.ocde.none.fl_str_mv |
https://purl.org/pe-repo/ocde/ford#2.10.00 |
description |
371-2012-CONCYTEC-OAJ |
publishDate |
2014 |
dc.date.accessioned.none.fl_str_mv |
2024-05-30T23:13:38Z |
dc.date.available.none.fl_str_mv |
2024-05-30T23:13:38Z |
dc.date.issued.fl_str_mv |
2014 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
dc.identifier.uri.none.fl_str_mv |
https://hdl.handle.net/20.500.12390/1261 |
dc.identifier.doi.none.fl_str_mv |
https://doi.org/10.1016/j.micromeso.2013.11.014 |
dc.identifier.isi.none.fl_str_mv |
330930400010 |
url |
https://hdl.handle.net/20.500.12390/1261 https://doi.org/10.1016/j.micromeso.2013.11.014 |
identifier_str_mv |
330930400010 |
dc.language.iso.none.fl_str_mv |
eng |
language |
eng |
dc.relation.ispartof.none.fl_str_mv |
Microporous and Mesoporous Materials |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.publisher.none.fl_str_mv |
Elsevier |
publisher.none.fl_str_mv |
Elsevier |
dc.source.none.fl_str_mv |
reponame:CONCYTEC-Institucional instname:Consejo Nacional de Ciencia Tecnología e Innovación instacron:CONCYTEC |
instname_str |
Consejo Nacional de Ciencia Tecnología e Innovación |
instacron_str |
CONCYTEC |
institution |
CONCYTEC |
reponame_str |
CONCYTEC-Institucional |
collection |
CONCYTEC-Institucional |
repository.name.fl_str_mv |
Repositorio Institucional CONCYTEC |
repository.mail.fl_str_mv |
repositorio@concytec.gob.pe |
_version_ |
1839175545262178304 |
score |
13.439101 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).