Feasibility of reverberant shear wave elastography for in vivo assessment of skeletal muscle viscoelasticity
Descripción del Articulo
Quantifying the local stiffness of muscular tissue can be a useful tool for the improvement of diagnosis, treatment or monitoring of muscle abnormality-related diseases. Shear wave elastography techniques provide information about tissue stiffness by measuring the shear wave speed (SWS). Recently, a...
Autores: | , , , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2020 |
Institución: | Consejo Nacional de Ciencia Tecnología e Innovación |
Repositorio: | CONCYTEC-Institucional |
Lenguaje: | inglés |
OAI Identifier: | oai:repositorio.concytec.gob.pe:20.500.12390/2489 |
Enlace del recurso: | https://hdl.handle.net/20.500.12390/2489 https://doi.org/10.1109/IUS46767.2020.9251504 |
Nivel de acceso: | acceso abierto |
Materia: | Viscoelasticity Elastography Muscle Reverberant field Shear wave speed Ultrasound http://purl.org/pe-repo/ocde/ford#3.01.01 |
id |
CONC_26721dfcfbed4c52987552903f3bf130 |
---|---|
oai_identifier_str |
oai:repositorio.concytec.gob.pe:20.500.12390/2489 |
network_acronym_str |
CONC |
network_name_str |
CONCYTEC-Institucional |
repository_id_str |
4689 |
dc.title.none.fl_str_mv |
Feasibility of reverberant shear wave elastography for in vivo assessment of skeletal muscle viscoelasticity |
title |
Feasibility of reverberant shear wave elastography for in vivo assessment of skeletal muscle viscoelasticity |
spellingShingle |
Feasibility of reverberant shear wave elastography for in vivo assessment of skeletal muscle viscoelasticity MacHado E. Viscoelasticity Elastography Muscle Reverberant field Shear wave speed Ultrasound http://purl.org/pe-repo/ocde/ford#3.01.01 |
title_short |
Feasibility of reverberant shear wave elastography for in vivo assessment of skeletal muscle viscoelasticity |
title_full |
Feasibility of reverberant shear wave elastography for in vivo assessment of skeletal muscle viscoelasticity |
title_fullStr |
Feasibility of reverberant shear wave elastography for in vivo assessment of skeletal muscle viscoelasticity |
title_full_unstemmed |
Feasibility of reverberant shear wave elastography for in vivo assessment of skeletal muscle viscoelasticity |
title_sort |
Feasibility of reverberant shear wave elastography for in vivo assessment of skeletal muscle viscoelasticity |
author |
MacHado E. |
author_facet |
MacHado E. Romero S.E. Flores G. Castaneda B. |
author_role |
author |
author2 |
Romero S.E. Flores G. Castaneda B. |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
MacHado E. Romero S.E. Flores G. Castaneda B. |
dc.subject.none.fl_str_mv |
Viscoelasticity |
topic |
Viscoelasticity Elastography Muscle Reverberant field Shear wave speed Ultrasound http://purl.org/pe-repo/ocde/ford#3.01.01 |
dc.subject.es_PE.fl_str_mv |
Elastography Muscle Reverberant field Shear wave speed Ultrasound |
dc.subject.ocde.none.fl_str_mv |
http://purl.org/pe-repo/ocde/ford#3.01.01 |
description |
Quantifying the local stiffness of muscular tissue can be a useful tool for the improvement of diagnosis, treatment or monitoring of muscle abnormality-related diseases. Shear wave elastography techniques provide information about tissue stiffness by measuring the shear wave speed (SWS). Recently, a new framework involving the generation of a reverberant shear wave field that propagates in all directions within the medium was proposed. The aim of this study is to evaluate the feasibility of Reverberant Shear Wave Elastography (R-SWE) for the in vivo assessment of the viscoelastic properties of skeletal muscle, using the biceps brachii. Four experiments were performed at a vibration frequency range between 200-300 Hz in steps of 50 Hz, with the ultrasound transducer placed along the muscle fibers in both relaxed and contracted (MVC) states. The estimation of the SWS and a dispersion analysis using the Kelvin-Voigt Fractional Derivative (KVFD) model were carried out in order to assess the viscoelastic properties of the muscular tissue. Preliminary results show that R-SWE is feasible to use for the in vivo assessment of skeletal muscle by using a multifrequency approach. The viscoelastic parameters obtained by the KVFD curve-fitting and the dispersion analysis showed the expected differences between the relaxed and MVC states (i.e. a significant difference between the coefficient of viscosity and the dispersion rate of change). The SWS estimation also showed differences between the two states (e.g. a difference in SWS values of 35.52% at 300 Hz). © 2020 IEEE. |
publishDate |
2020 |
dc.date.accessioned.none.fl_str_mv |
2024-05-30T23:13:38Z |
dc.date.available.none.fl_str_mv |
2024-05-30T23:13:38Z |
dc.date.issued.fl_str_mv |
2020 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
dc.identifier.uri.none.fl_str_mv |
https://hdl.handle.net/20.500.12390/2489 |
dc.identifier.doi.none.fl_str_mv |
https://doi.org/10.1109/IUS46767.2020.9251504 |
dc.identifier.scopus.none.fl_str_mv |
2-s2.0-85097905009 |
url |
https://hdl.handle.net/20.500.12390/2489 https://doi.org/10.1109/IUS46767.2020.9251504 |
identifier_str_mv |
2-s2.0-85097905009 |
dc.language.iso.none.fl_str_mv |
eng |
language |
eng |
dc.relation.ispartof.none.fl_str_mv |
IEEE International Ultrasonics Symposium, IUS |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.publisher.none.fl_str_mv |
IEEE Computer Society |
publisher.none.fl_str_mv |
IEEE Computer Society |
dc.source.none.fl_str_mv |
reponame:CONCYTEC-Institucional instname:Consejo Nacional de Ciencia Tecnología e Innovación instacron:CONCYTEC |
instname_str |
Consejo Nacional de Ciencia Tecnología e Innovación |
instacron_str |
CONCYTEC |
institution |
CONCYTEC |
reponame_str |
CONCYTEC-Institucional |
collection |
CONCYTEC-Institucional |
repository.name.fl_str_mv |
Repositorio Institucional CONCYTEC |
repository.mail.fl_str_mv |
repositorio@concytec.gob.pe |
_version_ |
1839175831782424576 |
spelling |
Publicationrp06357600rp06355600rp06356600rp05402600MacHado E.Romero S.E.Flores G.Castaneda B.2024-05-30T23:13:38Z2024-05-30T23:13:38Z2020https://hdl.handle.net/20.500.12390/2489https://doi.org/10.1109/IUS46767.2020.92515042-s2.0-85097905009Quantifying the local stiffness of muscular tissue can be a useful tool for the improvement of diagnosis, treatment or monitoring of muscle abnormality-related diseases. Shear wave elastography techniques provide information about tissue stiffness by measuring the shear wave speed (SWS). Recently, a new framework involving the generation of a reverberant shear wave field that propagates in all directions within the medium was proposed. The aim of this study is to evaluate the feasibility of Reverberant Shear Wave Elastography (R-SWE) for the in vivo assessment of the viscoelastic properties of skeletal muscle, using the biceps brachii. Four experiments were performed at a vibration frequency range between 200-300 Hz in steps of 50 Hz, with the ultrasound transducer placed along the muscle fibers in both relaxed and contracted (MVC) states. The estimation of the SWS and a dispersion analysis using the Kelvin-Voigt Fractional Derivative (KVFD) model were carried out in order to assess the viscoelastic properties of the muscular tissue. Preliminary results show that R-SWE is feasible to use for the in vivo assessment of skeletal muscle by using a multifrequency approach. The viscoelastic parameters obtained by the KVFD curve-fitting and the dispersion analysis showed the expected differences between the relaxed and MVC states (i.e. a significant difference between the coefficient of viscosity and the dispersion rate of change). The SWS estimation also showed differences between the two states (e.g. a difference in SWS values of 35.52% at 300 Hz). © 2020 IEEE.Consejo Nacional de Ciencia, Tecnología e Innovación Tecnológica - ConcytecengIEEE Computer SocietyIEEE International Ultrasonics Symposium, IUSinfo:eu-repo/semantics/openAccessViscoelasticityElastography-1Muscle-1Reverberant field-1Shear wave speed-1Ultrasound-1http://purl.org/pe-repo/ocde/ford#3.01.01-1Feasibility of reverberant shear wave elastography for in vivo assessment of skeletal muscle viscoelasticityinfo:eu-repo/semantics/articlereponame:CONCYTEC-Institucionalinstname:Consejo Nacional de Ciencia Tecnología e Innovacióninstacron:CONCYTEC20.500.12390/2489oai:repositorio.concytec.gob.pe:20.500.12390/24892024-05-30 16:08:40.162http://purl.org/coar/access_right/c_14cbinfo:eu-repo/semantics/closedAccessmetadata only accesshttps://repositorio.concytec.gob.peRepositorio Institucional CONCYTECrepositorio@concytec.gob.pe#PLACEHOLDER_PARENT_METADATA_VALUE##PLACEHOLDER_PARENT_METADATA_VALUE##PLACEHOLDER_PARENT_METADATA_VALUE##PLACEHOLDER_PARENT_METADATA_VALUE#<Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="fda15ac5-c80f-422d-a751-c88c04216767"> <Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843</Type> <Language>eng</Language> <Title>Feasibility of reverberant shear wave elastography for in vivo assessment of skeletal muscle viscoelasticity</Title> <PublishedIn> <Publication> <Title>IEEE International Ultrasonics Symposium, IUS</Title> </Publication> </PublishedIn> <PublicationDate>2020</PublicationDate> <DOI>https://doi.org/10.1109/IUS46767.2020.9251504</DOI> <SCP-Number>2-s2.0-85097905009</SCP-Number> <Authors> <Author> <DisplayName>MacHado E.</DisplayName> <Person id="rp06357" /> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> <Author> <DisplayName>Romero S.E.</DisplayName> <Person id="rp06355" /> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> <Author> <DisplayName>Flores G.</DisplayName> <Person id="rp06356" /> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> <Author> <DisplayName>Castaneda B.</DisplayName> <Person id="rp05402" /> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>IEEE Computer Society</DisplayName> <OrgUnit /> </Publisher> </Publishers> <Keyword>Viscoelasticity</Keyword> <Keyword>Elastography</Keyword> <Keyword>Muscle</Keyword> <Keyword>Reverberant field</Keyword> <Keyword>Shear wave speed</Keyword> <Keyword>Ultrasound</Keyword> <Abstract>Quantifying the local stiffness of muscular tissue can be a useful tool for the improvement of diagnosis, treatment or monitoring of muscle abnormality-related diseases. Shear wave elastography techniques provide information about tissue stiffness by measuring the shear wave speed (SWS). Recently, a new framework involving the generation of a reverberant shear wave field that propagates in all directions within the medium was proposed. The aim of this study is to evaluate the feasibility of Reverberant Shear Wave Elastography (R-SWE) for the in vivo assessment of the viscoelastic properties of skeletal muscle, using the biceps brachii. Four experiments were performed at a vibration frequency range between 200-300 Hz in steps of 50 Hz, with the ultrasound transducer placed along the muscle fibers in both relaxed and contracted (MVC) states. The estimation of the SWS and a dispersion analysis using the Kelvin-Voigt Fractional Derivative (KVFD) model were carried out in order to assess the viscoelastic properties of the muscular tissue. Preliminary results show that R-SWE is feasible to use for the in vivo assessment of skeletal muscle by using a multifrequency approach. The viscoelastic parameters obtained by the KVFD curve-fitting and the dispersion analysis showed the expected differences between the relaxed and MVC states (i.e. a significant difference between the coefficient of viscosity and the dispersion rate of change). The SWS estimation also showed differences between the two states (e.g. a difference in SWS values of 35.52% at 300 Hz). © 2020 IEEE.</Abstract> <Access xmlns="http://purl.org/coar/access_right" > </Access> </Publication> -1 |
score |
13.430107 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).