Inhibición de la corrosión del acero ASTM A192 en solución de ácido clorhídrico por el mucilago de Linum usitatissimum

Descripción del Articulo

In this study, the inhibition of the corrosion of ASTM A192 steel in HCl 0,5 M at temperature different, by the Linum usitatissimum mucilage, was investigated using techniques: Tafel extrapolation, linear polarization resistance, electrochemical impedance spectroscopy and electrochemical frequency m...

Descripción completa

Detalles Bibliográficos
Autores: Zavaleta-Gutierrez, Nilthon Emerson, Polo-Briceño, Elmer Rolando, Siche, Raúl, Angelats-Silva, Luis Manuel
Formato: artículo
Fecha de Publicación:2018
Institución:Consejo Nacional de Ciencia Tecnología e Innovación
Repositorio:CONCYTEC-Institucional
Lenguaje:español
OAI Identifier:oai:repositorio.concytec.gob.pe:20.500.12390/1300
Enlace del recurso:https://hdl.handle.net/20.500.12390/1300
https://doi.org/10.1590/s1517-707620180002.0390
Nivel de acceso:acceso abierto
Materia:Linum usitatissimum
acero ASTM A192
inhibición ácida
EIS
EFM
https://purl.org/pe-repo/ocde/ford#1.04.01
Descripción
Sumario:In this study, the inhibition of the corrosion of ASTM A192 steel in HCl 0,5 M at temperature different, by the Linum usitatissimum mucilage, was investigated using techniques: Tafel extrapolation, linear polarization resistance, electrochemical impedance spectroscopy and electrochemical frequency modulation. The Linum mucilage acts as an optimum corrosion inhibitor of ASTM A192 steel in HCl. The average inhibition efficiency obtained with the evaluated techniques were of 84,3% at 25 °C, 89,0% at 45 °C and 91,8% at 65 °C, with a concentration of the mucilage of 1 g/l. It was found that the efficiency of inhibition and the adsorption constant increased with increasing temperature. The standard enthalpy of adsorption was positive and the apparent activation energy decreased with the increase of the concentration of the mucilage. All these parameters indicate that the adsorption of flaxseed mucilage in steel evaluated occurs through a chemical adsorption. In addition, as the temperature increases, mucilage behavior changes from an anodic inhibitor to a mixed-type inhibitor.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).