Thermal performance evaluation of isolation and two active solar heating systems for an experimental module: A rural Peruvian case at 3700 masl

Descripción del Articulo

Evaluation results of the thermal performance of an experimental housing module (EHM) are presented with considerations for the level of insulation and the installation of two active heaters powered by solar energy. The EHM is located in a high Andean rural area in southern Peru (latitude: 13° 45�...

Descripción completa

Detalles Bibliográficos
Autores: Molina J.O., Espinoza R.E., Horn M.J., Gómez M.M.
Formato: objeto de conferencia
Fecha de Publicación:2019
Institución:Consejo Nacional de Ciencia Tecnología e Innovación
Repositorio:CONCYTEC-Institucional
Lenguaje:inglés
OAI Identifier:oai:repositorio.concytec.gob.pe:20.500.12390/805
Enlace del recurso:https://hdl.handle.net/20.500.12390/805
https://doi.org/10.1088/1742-6596/1173/1/012003
Nivel de acceso:acceso abierto
Materia:Thermal performance evaluations
Rural areas
Solar energy
Solar heating
Thermal insulation
Design and implementations
Evaluation results
Experimental modules
In-situ measurement
Interior temperature
Thermal evaluations
Thermal Performance
C (programming language)
https://purl.org/pe-repo/ocde/ford#1.05.09
Descripción
Sumario:Evaluation results of the thermal performance of an experimental housing module (EHM) are presented with considerations for the level of insulation and the installation of two active heaters powered by solar energy. The EHM is located in a high Andean rural area in southern Peru (latitude: 13° 45'40" S, longitude: 73° 51'26" W, and elevation: 3700 masl), where in situ measurements were made. The design and implementation of the EHM was based on the application of bioclimatic strategies and techniques. For the thermal evaluation of the EHM, 43 temperature sensors connected to dataloggers were used. The results show that the temperature inside the EHM increased more than 12 °C with respect to the outside temperature in the critical hours of extreme cold and frost when the isolation and the proposed radiative systems are used. Finally, the thermal behavior of the EHM was simulated using the EnergyPlus 8.4 program, which showed that there was an average difference of 0.5 °C between the measured interior temperature and the corresponding simulated temperature.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).