Evaluation of thermal behavior of a wall construction system in the high andean zone using an experimental module
Descripción del Articulo
        This article aims to evaluate the thermal behavior of a construction system consisting of fired red clay brick walls with cavities, commonly used in large cities in Peru and increasingly adopted in high-altitude Andean areas without being evaluated for frost climates. Consequently, an experimental m...
              
            
    
                        | Autores: | , , | 
|---|---|
| Formato: | artículo | 
| Fecha de Publicación: | 2024 | 
| Institución: | Universidad Nacional de Ingeniería | 
| Repositorio: | Revistas - Universidad Nacional de Ingeniería | 
| Lenguaje: | español | 
| OAI Identifier: | oai:oai:revistas.uni.edu.pe:article/2170 | 
| Enlace del recurso: | https://revistas.uni.edu.pe/index.php/tecnia/article/view/2170 | 
| Nivel de acceso: | acceso abierto | 
| Materia: | Comportamiento térmico Módulo experimental Simulación térmica EnergyPlus Energía Solar Thermal behavior Experimental module Thermal simulation Solar Energy | 
| Sumario: | This article aims to evaluate the thermal behavior of a construction system consisting of fired red clay brick walls with cavities, commonly used in large cities in Peru and increasingly adopted in high-altitude Andean areas without being evaluated for frost climates. Consequently, an experimental module was constructed at a real scale at 4500 masl. The experimentation carried out over 49 days shows that the thermal delay and decrement factor are 4 hours and 0.27, respectively, with the daily hourly average thermal amplitude indoors being 6.4°C and outdoors being 17.1°C. Additionally, the numerical study using EnergyPlus software and the implementation of the equivalent model of a set of homogeneous layers for heterogeneous materials, which dynamically considers the heat transfer modes by conduction, convection, and radiation, achieve good agreements of the indoor temperature between the measured and simulated values with R2 indices of 0.87 and RMSE of 0.91, validating the experimental module model. | 
|---|
 Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
    La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
 
   
   
             
            