Static, Dynamic, and High Cycle Fatigue Analysis of Crossed Spherical Gearing for Robotic Arm Ball Joint: A Finite Element Analysis Approach

Descripción del Articulo

Crossed spherical gearing is used in the joints of robotic arm prostheses and allows mobility in 3 degrees of freedom. This paper aims to evaluate the design of a cross-spherical gear with three different materials, PEEK, AISI 304L, and Ti-6Al-4V, for a robotic arm prosthesis by finite element analy...

Descripción completa

Detalles Bibliográficos
Autores: Serna-Landivar, José L., Risco Sernaqué, Madelaine Violeta, Rivas Moreano, Ana Beatriz, C. Algoner, William, Anticona-Valderrama, Daniela M., Zúñiga Porras, Walter Enrique, Oliva Guevara, Carlos
Formato: artículo
Fecha de Publicación:2023
Institución:Universidad Autónoma del Perú
Repositorio:AUTONOMA-Institucional
Lenguaje:inglés
OAI Identifier:oai:repositorio.autonoma.edu.pe:20.500.13067/3177
Enlace del recurso:https://hdl.handle.net/20.500.13067/3177
https://doi.org/10.3991/ijoe.v20i02.46817
Nivel de acceso:acceso abierto
Materia:Crossed spherical gearing
Static analysis
Modal analysis
Fatigue analysis
Robotic arm prosthesis
https://purl.org/pe-repo/ocde/ford#2.02.04
id AUTO_390482f2a574f9ec659edabd7de64e17
oai_identifier_str oai:repositorio.autonoma.edu.pe:20.500.13067/3177
network_acronym_str AUTO
network_name_str AUTONOMA-Institucional
repository_id_str 4774
spelling Serna-Landivar, José L.Risco Sernaqué, Madelaine VioletaRivas Moreano, Ana BeatrizC. Algoner, WilliamAnticona-Valderrama, Daniela M.Zúñiga Porras, Walter EnriqueOliva Guevara, Carlos2024-05-23T14:53:07Z2024-05-23T14:53:07Z2023https://hdl.handle.net/20.500.13067/3177International Journal of Online and Biomedical Engineering (iJOE)https://doi.org/10.3991/ijoe.v20i02.46817Crossed spherical gearing is used in the joints of robotic arm prostheses and allows mobility in 3 degrees of freedom. This paper aims to evaluate the design of a cross-spherical gear with three different materials, PEEK, AISI 304L, and Ti-6Al-4V, for a robotic arm prosthesis by finite element analysis. ANSYS mechanical software (version 2021 R1) was used to perform the static analysis and evaluate the deformations and stresses, modal analysis of natural frequencies and vibration modes, and high cycle fatigue analysis to determine fatigue resistance. The results obtained in the static analysis show that the maximum stresses are in the same zones for the three materials and have similar values. However, the Ti-6Al-4V and ASI 304L materials have a higher safety factor than PEEK, with a value of 5.17. In conclusion, the crossed spherical gearing is numerically validated using the finite element analysis so that the prototype can be later manufactured at an experimental level, and the values obtained for the crossed spherical gearing of the robotic arm prosthesis can be verified.application/pdfengInternational Journal of Online and Biomedical Engineering (iJOE)info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by/4.0/Crossed spherical gearingStatic analysisModal analysisFatigue analysisRobotic arm prosthesishttps://purl.org/pe-repo/ocde/ford#2.02.04Static, Dynamic, and High Cycle Fatigue Analysis of Crossed Spherical Gearing for Robotic Arm Ball Joint: A Finite Element Analysis Approachinfo:eu-repo/semantics/article2021630reponame:AUTONOMA-Institucionalinstname:Universidad Autónoma del Perúinstacron:AUTONOMAORIGINAL16.pdf16.pdfArtículoapplication/pdf1701316http://repositorio.autonoma.edu.pe/bitstream/20.500.13067/3177/1/16.pdf1547c5da05b197f6aa06b0e3eea1728dMD51LICENSElicense.txtlicense.txttext/plain; charset=utf-885http://repositorio.autonoma.edu.pe/bitstream/20.500.13067/3177/2/license.txt9243398ff393db1861c890baeaeee5f9MD52TEXT16.pdf.txt16.pdf.txtExtracted texttext/plain41372http://repositorio.autonoma.edu.pe/bitstream/20.500.13067/3177/3/16.pdf.txtbcc0c887f4ae326579d4126fa16082c2MD53THUMBNAIL16.pdf.jpg16.pdf.jpgGenerated Thumbnailimage/jpeg6701http://repositorio.autonoma.edu.pe/bitstream/20.500.13067/3177/4/16.pdf.jpgac76a3c65ee26b54e6cc979d0dae9f55MD5420.500.13067/3177oai:repositorio.autonoma.edu.pe:20.500.13067/31772025-01-06 15:45:12.677Repositorio de la Universidad Autonoma del Perúrepositorio@autonoma.peVG9kb3MgbG9zIGRlcmVjaG9zIHJlc2VydmFkb3MgcG9yOg0KVU5JVkVSU0lEQUQgQVVUw5NOT01BIERFTCBQRVLDmg0KQ1JFQVRJVkUgQ09NTU9OUw==
dc.title.es_PE.fl_str_mv Static, Dynamic, and High Cycle Fatigue Analysis of Crossed Spherical Gearing for Robotic Arm Ball Joint: A Finite Element Analysis Approach
title Static, Dynamic, and High Cycle Fatigue Analysis of Crossed Spherical Gearing for Robotic Arm Ball Joint: A Finite Element Analysis Approach
spellingShingle Static, Dynamic, and High Cycle Fatigue Analysis of Crossed Spherical Gearing for Robotic Arm Ball Joint: A Finite Element Analysis Approach
Serna-Landivar, José L.
Crossed spherical gearing
Static analysis
Modal analysis
Fatigue analysis
Robotic arm prosthesis
https://purl.org/pe-repo/ocde/ford#2.02.04
title_short Static, Dynamic, and High Cycle Fatigue Analysis of Crossed Spherical Gearing for Robotic Arm Ball Joint: A Finite Element Analysis Approach
title_full Static, Dynamic, and High Cycle Fatigue Analysis of Crossed Spherical Gearing for Robotic Arm Ball Joint: A Finite Element Analysis Approach
title_fullStr Static, Dynamic, and High Cycle Fatigue Analysis of Crossed Spherical Gearing for Robotic Arm Ball Joint: A Finite Element Analysis Approach
title_full_unstemmed Static, Dynamic, and High Cycle Fatigue Analysis of Crossed Spherical Gearing for Robotic Arm Ball Joint: A Finite Element Analysis Approach
title_sort Static, Dynamic, and High Cycle Fatigue Analysis of Crossed Spherical Gearing for Robotic Arm Ball Joint: A Finite Element Analysis Approach
author Serna-Landivar, José L.
author_facet Serna-Landivar, José L.
Risco Sernaqué, Madelaine Violeta
Rivas Moreano, Ana Beatriz
C. Algoner, William
Anticona-Valderrama, Daniela M.
Zúñiga Porras, Walter Enrique
Oliva Guevara, Carlos
author_role author
author2 Risco Sernaqué, Madelaine Violeta
Rivas Moreano, Ana Beatriz
C. Algoner, William
Anticona-Valderrama, Daniela M.
Zúñiga Porras, Walter Enrique
Oliva Guevara, Carlos
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Serna-Landivar, José L.
Risco Sernaqué, Madelaine Violeta
Rivas Moreano, Ana Beatriz
C. Algoner, William
Anticona-Valderrama, Daniela M.
Zúñiga Porras, Walter Enrique
Oliva Guevara, Carlos
dc.subject.es_PE.fl_str_mv Crossed spherical gearing
Static analysis
Modal analysis
Fatigue analysis
Robotic arm prosthesis
topic Crossed spherical gearing
Static analysis
Modal analysis
Fatigue analysis
Robotic arm prosthesis
https://purl.org/pe-repo/ocde/ford#2.02.04
dc.subject.ocde.es_PE.fl_str_mv https://purl.org/pe-repo/ocde/ford#2.02.04
description Crossed spherical gearing is used in the joints of robotic arm prostheses and allows mobility in 3 degrees of freedom. This paper aims to evaluate the design of a cross-spherical gear with three different materials, PEEK, AISI 304L, and Ti-6Al-4V, for a robotic arm prosthesis by finite element analysis. ANSYS mechanical software (version 2021 R1) was used to perform the static analysis and evaluate the deformations and stresses, modal analysis of natural frequencies and vibration modes, and high cycle fatigue analysis to determine fatigue resistance. The results obtained in the static analysis show that the maximum stresses are in the same zones for the three materials and have similar values. However, the Ti-6Al-4V and ASI 304L materials have a higher safety factor than PEEK, with a value of 5.17. In conclusion, the crossed spherical gearing is numerically validated using the finite element analysis so that the prototype can be later manufactured at an experimental level, and the values obtained for the crossed spherical gearing of the robotic arm prosthesis can be verified.
publishDate 2023
dc.date.accessioned.none.fl_str_mv 2024-05-23T14:53:07Z
dc.date.available.none.fl_str_mv 2024-05-23T14:53:07Z
dc.date.issued.fl_str_mv 2023
dc.type.es_PE.fl_str_mv info:eu-repo/semantics/article
format article
dc.identifier.uri.none.fl_str_mv https://hdl.handle.net/20.500.13067/3177
dc.identifier.journal.es_PE.fl_str_mv International Journal of Online and Biomedical Engineering (iJOE)
dc.identifier.doi.es_PE.fl_str_mv https://doi.org/10.3991/ijoe.v20i02.46817
url https://hdl.handle.net/20.500.13067/3177
https://doi.org/10.3991/ijoe.v20i02.46817
identifier_str_mv International Journal of Online and Biomedical Engineering (iJOE)
dc.language.iso.es_PE.fl_str_mv eng
language eng
dc.rights.es_PE.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.uri.es_PE.fl_str_mv https://creativecommons.org/licenses/by/4.0/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/4.0/
dc.format.es_PE.fl_str_mv application/pdf
dc.publisher.es_PE.fl_str_mv International Journal of Online and Biomedical Engineering (iJOE)
dc.source.none.fl_str_mv reponame:AUTONOMA-Institucional
instname:Universidad Autónoma del Perú
instacron:AUTONOMA
instname_str Universidad Autónoma del Perú
instacron_str AUTONOMA
institution AUTONOMA
reponame_str AUTONOMA-Institucional
collection AUTONOMA-Institucional
dc.source.volume.es_PE.fl_str_mv 20
dc.source.issue.es_PE.fl_str_mv 2
dc.source.beginpage.es_PE.fl_str_mv 16
dc.source.endpage.es_PE.fl_str_mv 30
bitstream.url.fl_str_mv http://repositorio.autonoma.edu.pe/bitstream/20.500.13067/3177/1/16.pdf
http://repositorio.autonoma.edu.pe/bitstream/20.500.13067/3177/2/license.txt
http://repositorio.autonoma.edu.pe/bitstream/20.500.13067/3177/3/16.pdf.txt
http://repositorio.autonoma.edu.pe/bitstream/20.500.13067/3177/4/16.pdf.jpg
bitstream.checksum.fl_str_mv 1547c5da05b197f6aa06b0e3eea1728d
9243398ff393db1861c890baeaeee5f9
bcc0c887f4ae326579d4126fa16082c2
ac76a3c65ee26b54e6cc979d0dae9f55
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
repository.name.fl_str_mv Repositorio de la Universidad Autonoma del Perú
repository.mail.fl_str_mv repositorio@autonoma.pe
_version_ 1835915507003293696
score 13.882472
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).