Comparative radiological study of cardiac parameters between lined up and rotated dorsoventral view of the thorax

Descripción del Articulo

The aim of this study was to compare the cardiac parameters of chest X-rays with aligned dorsoventral view with those of the rotated dorsoventral view of the same patient to determine the acceptable degree of rotation for these views. Fifty-three rotated dorsoventral plates from 32 canine patients w...

Descripción completa

Detalles Bibliográficos
Autores: Baldi Aste, Bianca M., Chilón, Jesús, Chipayo, Isaac, Díaz C., Diego
Formato: artículo
Fecha de Publicación:2020
Institución:Universidad Nacional Mayor de San Marcos
Repositorio:Revista UNMSM - Revista de Investigaciones Veterinarias del Perú
Lenguaje:español
OAI Identifier:oai:ojs.csi.unmsm:article/17536
Enlace del recurso:https://revistasinvestigacion.unmsm.edu.pe/index.php/veterinaria/article/view/17536
Nivel de acceso:acceso abierto
Materia:canine
radiograph
dorsoventral
heart
caninos radiografía
corazón
id 1609-9117_def5cf49d37b9fccf9313fb0ba3f0ca8
oai_identifier_str oai:ojs.csi.unmsm:article/17536
network_acronym_str 1609-9117
repository_id_str .
network_name_str Revista UNMSM - Revista de Investigaciones Veterinarias del Perú
spelling Comparative radiological study of cardiac parameters between lined up and rotated dorsoventral view of the thoraxEstudio comparativo radiológico de los parámetros cardiacos entre imágenes alineadas y con desviación en la vista dorsoventral del tóraxBaldi Aste, Bianca M.Chilón, JesúsChipayo, IsaacDíaz C., Diegocanineradiographdorsoventralheartcaninos radiografíadorsoventralcorazónThe aim of this study was to compare the cardiac parameters of chest X-rays with aligned dorsoventral view with those of the rotated dorsoventral view of the same patient to determine the acceptable degree of rotation for these views. Fifty-three rotated dorsoventral plates from 32 canine patients were used and the parameters compared of those plates with their respective control samples or aligned dorsoventral plates. To do this, the clockface analogy test and the cardio-thoracic ratio were used and complemented with their respective right side-lateral view, allowing obtaining the angle of rotation. The results of the rotated samples were assigned to a group of 0.1º to 6º of rotation and to another group of 6º to 12º of rotation. Each cardiac chamber was evaluated with its respective control plate by the McNemar test. The group from 0.1º to 6º rotation presented a probability value of 0.1025 when evaluating the right atrium, 0.6547 for the left atrium, 0.1573 for the right ventricle and 0.3173 for the left ventricle, being valid for diagnosis; unlike the group of 6° to 12° rotation that obtained 0.0196 for the right atrium, 0.0578 for the left atrium, 0.0114 for the right ventricle and 0.0126 for the left ventricle, not being acceptable for diagnosis.El objetivo de este estudio fue comparar los parámetros cardiacos de radiografías de tórax de vista dorsoventral alineada con los de vista dorsoventral girada de un mismo paciente para determinar el grado de giro aceptable para dicha vista. Se utilizaron 53 placas dorsoventrales giradas de 32 pacientes caninos y se compararon los parámetros de dichas placas con sus respectivas muestras control o placas dorsoventrales alineadas. Para ello, se usaron las pruebas de analogía del reloj y relación cardio-torácica y complementadas con su respectiva vista latero-lateral derecha, permitiendo la obtención del ángulo de giro. Los resultados de las muestras giradas fueron asignadas a un grupo de 0.1º a 6º de giro y a otro de 6º a 12º de giro. Cada cámara cardiaca fue evaluada con su respectiva placa control mediante la prueba de McNemar. El grupo de 0.1º a 6º de giro presenta un valor de probabilidad de 0.1025 al evaluar la aurícula derecha, 0.6547 para la aurícula izquierda, 0.1573 para el ventrículo derecho y 0.3173 para el ventrículo izquierdo, siendo válido para diagnóstico; a diferencia del grupo de 6º a 12º de giro que obtuvo 0.0196 para la aurícula derecha, 0.0578 para la aurícula izquierda, 0.0114 para el ventrículo derecho y 0.0126 para el ventrículo izquierdo, no siendo aceptables para diagnóstico.Universidad Nacional Mayor de San Marcos, Facultad de Medicina Veterinaria2020-03-29info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistasinvestigacion.unmsm.edu.pe/index.php/veterinaria/article/view/1753610.15381/rivep.v31i1.17536Revista de Investigaciones Veterinarias del Perú; Vol 31 No 1 (2020); e17536Revista de Investigaciones Veterinarias del Perú; Vol. 31 Núm. 1 (2020); e175361682-34191609-9117reponame:Revista UNMSM - Revista de Investigaciones Veterinarias del Perúinstname:Universidad Nacional Mayor de San Marcosinstacron:UNMSMspahttps://revistasinvestigacion.unmsm.edu.pe/index.php/veterinaria/article/view/17536/14804Derechos de autor 2020 Bianca M. Baldi Aste, Jesús Chilón, Isaac Chipayo, Diego Díaz C.http://creativecommons.org/licenses/by-nc-sa/4.0info:eu-repo/semantics/openAccess2021-06-01T18:10:36Zmail@mail.com -
dc.title.none.fl_str_mv Comparative radiological study of cardiac parameters between lined up and rotated dorsoventral view of the thorax
Estudio comparativo radiológico de los parámetros cardiacos entre imágenes alineadas y con desviación en la vista dorsoventral del tórax
title Comparative radiological study of cardiac parameters between lined up and rotated dorsoventral view of the thorax
spellingShingle Comparative radiological study of cardiac parameters between lined up and rotated dorsoventral view of the thorax
Baldi Aste, Bianca M.
canine
radiograph
dorsoventral
heart
caninos radiografía
dorsoventral
corazón
title_short Comparative radiological study of cardiac parameters between lined up and rotated dorsoventral view of the thorax
title_full Comparative radiological study of cardiac parameters between lined up and rotated dorsoventral view of the thorax
title_fullStr Comparative radiological study of cardiac parameters between lined up and rotated dorsoventral view of the thorax
title_full_unstemmed Comparative radiological study of cardiac parameters between lined up and rotated dorsoventral view of the thorax
title_sort Comparative radiological study of cardiac parameters between lined up and rotated dorsoventral view of the thorax
dc.creator.none.fl_str_mv Baldi Aste, Bianca M.
Chilón, Jesús
Chipayo, Isaac
Díaz C., Diego
author Baldi Aste, Bianca M.
author_facet Baldi Aste, Bianca M.
Chilón, Jesús
Chipayo, Isaac
Díaz C., Diego
author_role author
author2 Chilón, Jesús
Chipayo, Isaac
Díaz C., Diego
author2_role author
author
author
dc.subject.none.fl_str_mv canine
radiograph
dorsoventral
heart
caninos radiografía
dorsoventral
corazón
topic canine
radiograph
dorsoventral
heart
caninos radiografía
dorsoventral
corazón
dc.description.none.fl_txt_mv The aim of this study was to compare the cardiac parameters of chest X-rays with aligned dorsoventral view with those of the rotated dorsoventral view of the same patient to determine the acceptable degree of rotation for these views. Fifty-three rotated dorsoventral plates from 32 canine patients were used and the parameters compared of those plates with their respective control samples or aligned dorsoventral plates. To do this, the clockface analogy test and the cardio-thoracic ratio were used and complemented with their respective right side-lateral view, allowing obtaining the angle of rotation. The results of the rotated samples were assigned to a group of 0.1º to 6º of rotation and to another group of 6º to 12º of rotation. Each cardiac chamber was evaluated with its respective control plate by the McNemar test. The group from 0.1º to 6º rotation presented a probability value of 0.1025 when evaluating the right atrium, 0.6547 for the left atrium, 0.1573 for the right ventricle and 0.3173 for the left ventricle, being valid for diagnosis; unlike the group of 6° to 12° rotation that obtained 0.0196 for the right atrium, 0.0578 for the left atrium, 0.0114 for the right ventricle and 0.0126 for the left ventricle, not being acceptable for diagnosis.
El objetivo de este estudio fue comparar los parámetros cardiacos de radiografías de tórax de vista dorsoventral alineada con los de vista dorsoventral girada de un mismo paciente para determinar el grado de giro aceptable para dicha vista. Se utilizaron 53 placas dorsoventrales giradas de 32 pacientes caninos y se compararon los parámetros de dichas placas con sus respectivas muestras control o placas dorsoventrales alineadas. Para ello, se usaron las pruebas de analogía del reloj y relación cardio-torácica y complementadas con su respectiva vista latero-lateral derecha, permitiendo la obtención del ángulo de giro. Los resultados de las muestras giradas fueron asignadas a un grupo de 0.1º a 6º de giro y a otro de 6º a 12º de giro. Cada cámara cardiaca fue evaluada con su respectiva placa control mediante la prueba de McNemar. El grupo de 0.1º a 6º de giro presenta un valor de probabilidad de 0.1025 al evaluar la aurícula derecha, 0.6547 para la aurícula izquierda, 0.1573 para el ventrículo derecho y 0.3173 para el ventrículo izquierdo, siendo válido para diagnóstico; a diferencia del grupo de 6º a 12º de giro que obtuvo 0.0196 para la aurícula derecha, 0.0578 para la aurícula izquierda, 0.0114 para el ventrículo derecho y 0.0126 para el ventrículo izquierdo, no siendo aceptables para diagnóstico.
description The aim of this study was to compare the cardiac parameters of chest X-rays with aligned dorsoventral view with those of the rotated dorsoventral view of the same patient to determine the acceptable degree of rotation for these views. Fifty-three rotated dorsoventral plates from 32 canine patients were used and the parameters compared of those plates with their respective control samples or aligned dorsoventral plates. To do this, the clockface analogy test and the cardio-thoracic ratio were used and complemented with their respective right side-lateral view, allowing obtaining the angle of rotation. The results of the rotated samples were assigned to a group of 0.1º to 6º of rotation and to another group of 6º to 12º of rotation. Each cardiac chamber was evaluated with its respective control plate by the McNemar test. The group from 0.1º to 6º rotation presented a probability value of 0.1025 when evaluating the right atrium, 0.6547 for the left atrium, 0.1573 for the right ventricle and 0.3173 for the left ventricle, being valid for diagnosis; unlike the group of 6° to 12° rotation that obtained 0.0196 for the right atrium, 0.0578 for the left atrium, 0.0114 for the right ventricle and 0.0126 for the left ventricle, not being acceptable for diagnosis.
publishDate 2020
dc.date.none.fl_str_mv 2020-03-29
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://revistasinvestigacion.unmsm.edu.pe/index.php/veterinaria/article/view/17536
10.15381/rivep.v31i1.17536
url https://revistasinvestigacion.unmsm.edu.pe/index.php/veterinaria/article/view/17536
identifier_str_mv 10.15381/rivep.v31i1.17536
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv https://revistasinvestigacion.unmsm.edu.pe/index.php/veterinaria/article/view/17536/14804
dc.rights.none.fl_str_mv Derechos de autor 2020 Bianca M. Baldi Aste, Jesús Chilón, Isaac Chipayo, Diego Díaz C.
http://creativecommons.org/licenses/by-nc-sa/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Derechos de autor 2020 Bianca M. Baldi Aste, Jesús Chilón, Isaac Chipayo, Diego Díaz C.
http://creativecommons.org/licenses/by-nc-sa/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidad Nacional Mayor de San Marcos, Facultad de Medicina Veterinaria
publisher.none.fl_str_mv Universidad Nacional Mayor de San Marcos, Facultad de Medicina Veterinaria
dc.source.none.fl_str_mv Revista de Investigaciones Veterinarias del Perú; Vol 31 No 1 (2020); e17536
Revista de Investigaciones Veterinarias del Perú; Vol. 31 Núm. 1 (2020); e17536
1682-3419
1609-9117
reponame:Revista UNMSM - Revista de Investigaciones Veterinarias del Perú
instname:Universidad Nacional Mayor de San Marcos
instacron:UNMSM
reponame_str Revista UNMSM - Revista de Investigaciones Veterinarias del Perú
collection Revista UNMSM - Revista de Investigaciones Veterinarias del Perú
instname_str Universidad Nacional Mayor de San Marcos
instacron_str UNMSM
institution UNMSM
repository.name.fl_str_mv -
repository.mail.fl_str_mv mail@mail.com
_version_ 1701389176925061120
score 13.87115
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).