GRAIN DRYING I: PRESSURE LOSS IN SPOUTING BED

Descripción del Articulo

It has been obtained a experimental drop in pressure as a result of making flow air through a column of spouted bed loaded with wheat grains. A built column of stainless steel is used whose traversa section in a semicircular way has 152.4 mm of diameter, it finishes in a base truncated cone whose en...

Descripción completa

Detalles Bibliográficos
Autor: Condorhuamán C., Cesario
Formato: artículo
Fecha de Publicación:2002
Institución:Universidad Nacional Mayor de San Marcos
Repositorio:Revista UNMSM - Revista Peruana de Química e Ingeniería Química
Lenguaje:español
OAI Identifier:oai:ojs.csi.unmsm:article/4330
Enlace del recurso:https://revistasinvestigacion.unmsm.edu.pe/index.php/quim/article/view/4330
Nivel de acceso:acceso abierto
Materia:losses of pressure
spouting bed
fixed bed
drying grain cereals
pérdidas de presión
lecho surtidor
lecho estático
secado de granos
id 1609-7599_e1a5b5a2eed0a17c1a4734e751d24fee
oai_identifier_str oai:ojs.csi.unmsm:article/4330
network_acronym_str 1609-7599
repository_id_str .
network_name_str Revista UNMSM - Revista Peruana de Química e Ingeniería Química
spelling GRAIN DRYING I: PRESSURE LOSS IN SPOUTING BEDSECADO DE GRANOS I: PÉRDIDA DE PRESIÓN EN LECHO SURTIDORCondorhuamán C., Cesariolosses of pressurespouting bedfixed beddrying grain cerealspérdidas de presiónlecho surtidorlecho estáticosecado de granosIt has been obtained a experimental drop in pressure as a result of making flow air through a column of spouted bed loaded with wheat grains. A built column of stainless steel is used whose traversa section in a semicircular way has 152.4 mm of diameter, it finishes in a base truncated cone whose entrance hale is other 1 semi-circulate of 12 .5 mm of diameter and it has a height of 1.30 meters. The results are obtained to standard conditions of pressure and temperature, The flows of air vary between 9.9 and 52.2 cubic meters per hour and losses of pressure are obtained between 6.4 and 14.1 KPa/m, respectively.Se han obtenido las pérdidas de presión experimentales como resultado de hacer fluir aire a través de una columna de lechos surtidor cargado con granos de trigo. Se emplea una columna de acero inoxidable cuya sección transversal, de forma semicircular, tiene 152.4 mm de diámetro, termina en una base cono truncado cuyo orificio de entrada es otro semicírculo de 12.5 mm de diámetro y una altura de 1.30 metros. Los resultados se obtienen a condiciones estándares de presión y temperatura. Los flujos de aire varían entre 9.9 y 52.2 metros cúbicos por hora y se obtienen pérdidas de presión entre 6.4 y 14.1 KPa/m respectivamente.Universidad Nacional Mayor de San Marcos2002-12-30info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistasinvestigacion.unmsm.edu.pe/index.php/quim/article/view/4330Revista Peruana de Química e Ingeniería Química; Vol 5 No 1 (2002); 16-22Revista Peruana de Química e Ingeniería Química; Vol. 5 Núm. 1 (2002); 16-221609-75991726-2208reponame:Revista UNMSM - Revista Peruana de Química e Ingeniería Químicainstname:Universidad Nacional Mayor de San Marcosinstacron:UNMSMspahttps://revistasinvestigacion.unmsm.edu.pe/index.php/quim/article/view/4330/5486Derechos de autor 2002 Cesario Condorhuamán C.http://creativecommons.org/licenses/by-nc-sa/4.0info:eu-repo/semantics/openAccess2021-06-01T18:10:45Zmail@mail.com -
dc.title.none.fl_str_mv GRAIN DRYING I: PRESSURE LOSS IN SPOUTING BED
SECADO DE GRANOS I: PÉRDIDA DE PRESIÓN EN LECHO SURTIDOR
title GRAIN DRYING I: PRESSURE LOSS IN SPOUTING BED
spellingShingle GRAIN DRYING I: PRESSURE LOSS IN SPOUTING BED
Condorhuamán C., Cesario
losses of pressure
spouting bed
fixed bed
drying grain cereals
pérdidas de presión
lecho surtidor
lecho estático
secado de granos
title_short GRAIN DRYING I: PRESSURE LOSS IN SPOUTING BED
title_full GRAIN DRYING I: PRESSURE LOSS IN SPOUTING BED
title_fullStr GRAIN DRYING I: PRESSURE LOSS IN SPOUTING BED
title_full_unstemmed GRAIN DRYING I: PRESSURE LOSS IN SPOUTING BED
title_sort GRAIN DRYING I: PRESSURE LOSS IN SPOUTING BED
dc.creator.none.fl_str_mv Condorhuamán C., Cesario
author Condorhuamán C., Cesario
author_facet Condorhuamán C., Cesario
author_role author
dc.subject.none.fl_str_mv losses of pressure
spouting bed
fixed bed
drying grain cereals
pérdidas de presión
lecho surtidor
lecho estático
secado de granos
topic losses of pressure
spouting bed
fixed bed
drying grain cereals
pérdidas de presión
lecho surtidor
lecho estático
secado de granos
dc.description.none.fl_txt_mv It has been obtained a experimental drop in pressure as a result of making flow air through a column of spouted bed loaded with wheat grains. A built column of stainless steel is used whose traversa section in a semicircular way has 152.4 mm of diameter, it finishes in a base truncated cone whose entrance hale is other 1 semi-circulate of 12 .5 mm of diameter and it has a height of 1.30 meters. The results are obtained to standard conditions of pressure and temperature, The flows of air vary between 9.9 and 52.2 cubic meters per hour and losses of pressure are obtained between 6.4 and 14.1 KPa/m, respectively.
Se han obtenido las pérdidas de presión experimentales como resultado de hacer fluir aire a través de una columna de lechos surtidor cargado con granos de trigo. Se emplea una columna de acero inoxidable cuya sección transversal, de forma semicircular, tiene 152.4 mm de diámetro, termina en una base cono truncado cuyo orificio de entrada es otro semicírculo de 12.5 mm de diámetro y una altura de 1.30 metros. Los resultados se obtienen a condiciones estándares de presión y temperatura. Los flujos de aire varían entre 9.9 y 52.2 metros cúbicos por hora y se obtienen pérdidas de presión entre 6.4 y 14.1 KPa/m respectivamente.
description It has been obtained a experimental drop in pressure as a result of making flow air through a column of spouted bed loaded with wheat grains. A built column of stainless steel is used whose traversa section in a semicircular way has 152.4 mm of diameter, it finishes in a base truncated cone whose entrance hale is other 1 semi-circulate of 12 .5 mm of diameter and it has a height of 1.30 meters. The results are obtained to standard conditions of pressure and temperature, The flows of air vary between 9.9 and 52.2 cubic meters per hour and losses of pressure are obtained between 6.4 and 14.1 KPa/m, respectively.
publishDate 2002
dc.date.none.fl_str_mv 2002-12-30
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://revistasinvestigacion.unmsm.edu.pe/index.php/quim/article/view/4330
url https://revistasinvestigacion.unmsm.edu.pe/index.php/quim/article/view/4330
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv https://revistasinvestigacion.unmsm.edu.pe/index.php/quim/article/view/4330/5486
dc.rights.none.fl_str_mv Derechos de autor 2002 Cesario Condorhuamán C.
http://creativecommons.org/licenses/by-nc-sa/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Derechos de autor 2002 Cesario Condorhuamán C.
http://creativecommons.org/licenses/by-nc-sa/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidad Nacional Mayor de San Marcos
publisher.none.fl_str_mv Universidad Nacional Mayor de San Marcos
dc.source.none.fl_str_mv Revista Peruana de Química e Ingeniería Química; Vol 5 No 1 (2002); 16-22
Revista Peruana de Química e Ingeniería Química; Vol. 5 Núm. 1 (2002); 16-22
1609-7599
1726-2208
reponame:Revista UNMSM - Revista Peruana de Química e Ingeniería Química
instname:Universidad Nacional Mayor de San Marcos
instacron:UNMSM
reponame_str Revista UNMSM - Revista Peruana de Química e Ingeniería Química
collection Revista UNMSM - Revista Peruana de Química e Ingeniería Química
instname_str Universidad Nacional Mayor de San Marcos
instacron_str UNMSM
institution UNMSM
repository.name.fl_str_mv -
repository.mail.fl_str_mv mail@mail.com
_version_ 1701389115319123968
score 13.949927
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).