Shear strength of brick mortar interface for masonry in Lima city
Descripción del Articulo
Masonry structures constitute a large proportion of the building inventory in Lima and in most cities in Peru, mainly because of their benefits in terms of low cost, good mechanical properties and easily worked. It was observed in the cyclic loading test of masonry walls carried out at CISMID that t...
| Autores: | , |
|---|---|
| Formato: | artículo |
| Fecha de Publicación: | 2019 |
| Institución: | Universidad Nacional de Ingeniería |
| Repositorio: | Revista UNI - Tecnia |
| Lenguaje: | español |
| OAI Identifier: | oai:oai:revistas.uni.edu.pe:article/707 |
| Enlace del recurso: | http://www.revistas.uni.edu.pe/index.php/tecnia/article/view/707 |
| Nivel de acceso: | acceso abierto |
| id |
0375-7765_f1fd7ca4a8a919422452a2e1aac5c95f |
|---|---|
| oai_identifier_str |
oai:oai:revistas.uni.edu.pe:article/707 |
| network_acronym_str |
0375-7765 |
| repository_id_str |
. |
| network_name_str |
Revista UNI - Tecnia |
| spelling |
Shear strength of brick mortar interface for masonry in Lima cityLavado, LuisGallardo, JorgeMasonry structures constitute a large proportion of the building inventory in Lima and in most cities in Peru, mainly because of their benefits in terms of low cost, good mechanical properties and easily worked. It was observed in the cyclic loading test of masonry walls carried out at CISMID that the modes of failures can be mainly generated by shear forces. Based on the previous information, it is known that diagonal cracking and slip of the mortar-brick joints are the dominant failure mechanisms of confined masonry walls. In order to determine the mechanical behavior in the mortar-brick joint, an experimental program was carried out, by using industrial and handmade bricks. The test specimens were specifically designed to transmit pure shear along the bed joints under certain constant levels of compressive stress normal to the bed joint. The results of experimental shear tests are presented and discussed. It is then found a consistency between the behavior of masonry joints under shear with the Mohr Coulomb criterion. The shear failure capacity was influenced by the brick type, pre-compression load level and mortar type. It is also noticed in this experimental study that the pre-compressive stress normal to the bed joints significantly increase the shear strength of the mortar-brick joint.Masonry structures constitute a large proportion of the building inventory in Lima and in most cities in Peru, mainly because of their benefits in terms of low cost, good mechanical properties and easily worked. It was observed in the cyclic loading test of masonry walls carried out at CISMID that the modes of failures can be mainly generated by shear forces. Based on the previous information, it is known that diagonal cracking and slip of the mortar-brick joints are the dominant failure mechanisms of confined masonry walls. In order to determine the mechanical behavior in the mortar-brick joint, an experimental program was carried out, by using industrial and handmade bricks. The test specimens were specifically designed to transmit pure shear along the bed joints under certain constant levels of compressive stress normal to the bed joint. The results of experimental shear tests are presented and discussed. It is then found a consistency between the behavior of masonry joints under shear with the Mohr Coulomb criterion. The shear failure capacity was influenced by the brick type, pre-compression load level and mortar type. It is also noticed in this experimental study that the pre-compressive stress normal to the bed joints significantly increase the shear strength of the mortar-brick joint.Universidad Nacional de Ingeniería2019-08-07info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionTECNIA Special Issue on Earthquake Engineeringapplication/pdfaudio/mpeghttp://www.revistas.uni.edu.pe/index.php/tecnia/article/view/70710.21754/tecnia.v29i2.707TECNIA; Vol 29 No 2 (2019): Special Issue on Earthquake EngineeringTECNIA; Vol. 29 Núm. 2 (2019): Edición especial en Ingeniería Sísmica2309-04130375-7765reponame:Revista UNI - Tecniainstname:Universidad Nacional de Ingenieríainstacron:UNIspahttp://www.revistas.uni.edu.pe/index.php/tecnia/article/view/707/1109http://www.revistas.uni.edu.pe/index.php/tecnia/article/view/707/1127info:eu-repo/semantics/openAccess2021-05-29T15:55:42Zmail@mail.com - |
| dc.title.none.fl_str_mv |
Shear strength of brick mortar interface for masonry in Lima city |
| title |
Shear strength of brick mortar interface for masonry in Lima city |
| spellingShingle |
Shear strength of brick mortar interface for masonry in Lima city Lavado, Luis |
| title_short |
Shear strength of brick mortar interface for masonry in Lima city |
| title_full |
Shear strength of brick mortar interface for masonry in Lima city |
| title_fullStr |
Shear strength of brick mortar interface for masonry in Lima city |
| title_full_unstemmed |
Shear strength of brick mortar interface for masonry in Lima city |
| title_sort |
Shear strength of brick mortar interface for masonry in Lima city |
| dc.creator.none.fl_str_mv |
Lavado, Luis Gallardo, Jorge |
| author |
Lavado, Luis |
| author_facet |
Lavado, Luis Gallardo, Jorge |
| author_role |
author |
| author2 |
Gallardo, Jorge |
| author2_role |
author |
| dc.description.none.fl_txt_mv |
Masonry structures constitute a large proportion of the building inventory in Lima and in most cities in Peru, mainly because of their benefits in terms of low cost, good mechanical properties and easily worked. It was observed in the cyclic loading test of masonry walls carried out at CISMID that the modes of failures can be mainly generated by shear forces. Based on the previous information, it is known that diagonal cracking and slip of the mortar-brick joints are the dominant failure mechanisms of confined masonry walls. In order to determine the mechanical behavior in the mortar-brick joint, an experimental program was carried out, by using industrial and handmade bricks. The test specimens were specifically designed to transmit pure shear along the bed joints under certain constant levels of compressive stress normal to the bed joint. The results of experimental shear tests are presented and discussed. It is then found a consistency between the behavior of masonry joints under shear with the Mohr Coulomb criterion. The shear failure capacity was influenced by the brick type, pre-compression load level and mortar type. It is also noticed in this experimental study that the pre-compressive stress normal to the bed joints significantly increase the shear strength of the mortar-brick joint. Masonry structures constitute a large proportion of the building inventory in Lima and in most cities in Peru, mainly because of their benefits in terms of low cost, good mechanical properties and easily worked. It was observed in the cyclic loading test of masonry walls carried out at CISMID that the modes of failures can be mainly generated by shear forces. Based on the previous information, it is known that diagonal cracking and slip of the mortar-brick joints are the dominant failure mechanisms of confined masonry walls. In order to determine the mechanical behavior in the mortar-brick joint, an experimental program was carried out, by using industrial and handmade bricks. The test specimens were specifically designed to transmit pure shear along the bed joints under certain constant levels of compressive stress normal to the bed joint. The results of experimental shear tests are presented and discussed. It is then found a consistency between the behavior of masonry joints under shear with the Mohr Coulomb criterion. The shear failure capacity was influenced by the brick type, pre-compression load level and mortar type. It is also noticed in this experimental study that the pre-compressive stress normal to the bed joints significantly increase the shear strength of the mortar-brick joint. |
| description |
Masonry structures constitute a large proportion of the building inventory in Lima and in most cities in Peru, mainly because of their benefits in terms of low cost, good mechanical properties and easily worked. It was observed in the cyclic loading test of masonry walls carried out at CISMID that the modes of failures can be mainly generated by shear forces. Based on the previous information, it is known that diagonal cracking and slip of the mortar-brick joints are the dominant failure mechanisms of confined masonry walls. In order to determine the mechanical behavior in the mortar-brick joint, an experimental program was carried out, by using industrial and handmade bricks. The test specimens were specifically designed to transmit pure shear along the bed joints under certain constant levels of compressive stress normal to the bed joint. The results of experimental shear tests are presented and discussed. It is then found a consistency between the behavior of masonry joints under shear with the Mohr Coulomb criterion. The shear failure capacity was influenced by the brick type, pre-compression load level and mortar type. It is also noticed in this experimental study that the pre-compressive stress normal to the bed joints significantly increase the shear strength of the mortar-brick joint. |
| publishDate |
2019 |
| dc.date.none.fl_str_mv |
2019-08-07 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion TECNIA Special Issue on Earthquake Engineering |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
http://www.revistas.uni.edu.pe/index.php/tecnia/article/view/707 10.21754/tecnia.v29i2.707 |
| url |
http://www.revistas.uni.edu.pe/index.php/tecnia/article/view/707 |
| identifier_str_mv |
10.21754/tecnia.v29i2.707 |
| dc.language.none.fl_str_mv |
spa |
| language |
spa |
| dc.relation.none.fl_str_mv |
http://www.revistas.uni.edu.pe/index.php/tecnia/article/view/707/1109 http://www.revistas.uni.edu.pe/index.php/tecnia/article/view/707/1127 |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf audio/mpeg |
| dc.publisher.none.fl_str_mv |
Universidad Nacional de Ingeniería |
| publisher.none.fl_str_mv |
Universidad Nacional de Ingeniería |
| dc.source.none.fl_str_mv |
TECNIA; Vol 29 No 2 (2019): Special Issue on Earthquake Engineering TECNIA; Vol. 29 Núm. 2 (2019): Edición especial en Ingeniería Sísmica 2309-0413 0375-7765 reponame:Revista UNI - Tecnia instname:Universidad Nacional de Ingeniería instacron:UNI |
| reponame_str |
Revista UNI - Tecnia |
| collection |
Revista UNI - Tecnia |
| instname_str |
Universidad Nacional de Ingeniería |
| instacron_str |
UNI |
| institution |
UNI |
| repository.name.fl_str_mv |
-
|
| repository.mail.fl_str_mv |
mail@mail.com |
| _version_ |
1701108800444956672 |
| score |
13.890295 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).