1
artículo
Publicado 2009
Enlace
Enlace
2843 inquiries were checked, pharmaceuticals and related products, made by the Control and Monitoring Equipment Establishments of DIGEMID from 2002 to 2006. The physicochemical and microbiological analyses were realized by the National Institute of Health and then evaluated by the Control and Monitoring Product. Of the whole of products were found that 65% are satisfied and 35% did not comply. The results of the non-compliant were classified to determine the main observations about quality: Unauthorized labeling 40%, Deficient product 27%, Critical 17%, Specification change 14%, Without sanitary record 1% and Unauthorized presentation form 1 %. In their investigation: 45% were brand name drugs, generic drugs 30%, 10% medical supplies and 9% cosmetics. Were in conformity: brand drugs 69%, generic drugs 64%, medical supplies 60% and cosmetics 68%. Regarding the type of pharmaceutical estab...
2
artículo
Publicado 2009
Enlace
Enlace
2843 inquiries were checked, pharmaceuticals and related products, made by the Control and Monitoring Equipment Establishments of DIGEMID from 2002 to 2006. The physicochemical and microbiological analyses were realized by the National Institute of Health and then evaluated by the Control and Monitoring Product. Of the whole of products were found that 65% are satisfied and 35% did not comply. The results of the non-compliant were classified to determine the main observations about quality: Unauthorized labeling 40%, Deficient product 27%, Critical 17%, Specification change 14%, Without sanitary record 1% and Unauthorized presentation form 1 %. In their investigation: 45% were brand name drugs, generic drugs 30%, 10% medical supplies and 9% cosmetics. Were in conformity: brand drugs 69%, generic drugs 64%, medical supplies 60% and cosmetics 68%. Regarding the type of pharmaceutical estab...
3
tesis de grado
Publicado 2008
Enlace
Enlace
Para este trabajo de investigación se recolectaron 2843 pesquisas de productos farmacéuticos y afines, realizados por el Equipo de Control y Vigilancia de Establecimientos de la DIGEMID en los años 2002 a 2006. Los estudios de los análisis fisicoquímicos y microbiológicos fueron realizados por el Instituto Nacional de Salud y luego evaluados por el Equipo de Control y Vigilancia de Productos de la DIGEMID. Se analizó el total de los productos pesquisados encontrándose que el 65% son conformes y 35% no conformes. Así mismo, los resultados no conformes se clasificaron para determinar las principales observaciones a la calidad: Rotulado No Autorizado 40%, Producto Deficiente 27%, Crítico 17%, Cambio de Especificación 14%, Sin Registro Sanitario 1% y Forma de Presentación No Autorizada 1%. Del total de las pesquisas realizadas: El 45% fueron medicamentos de marca, el 30% medicame...