Exportación Completada — 

A new approach to inertial damper design to control base displacement in isolated buildings

Descripción del Articulo

A novel design procedure for tuned mass dampers in isolated structures is presented. The proposed optimization method is specifically developed to control base displacements or to solve the large isolator displacement problem in this type of structures under earthquakes. Therefore, it is based on a...

Descripción completa

Detalles Bibliográficos
Autor: Morales, César A.
Formato: artículo
Fecha de Publicación:2022
Institución:Universidad Peruana de Ciencias Aplicadas
Repositorio:UPC-Institucional
Lenguaje:inglés
OAI Identifier:oai:repositorioacademico.upc.edu.pe:10757/668787
Enlace del recurso:http://hdl.handle.net/10757/668787
Nivel de acceso:acceso abierto
Materia:base displacement
base isolation
isolator displacement
passive control
transmissibility
Tuned mass damper
Descripción
Sumario:A novel design procedure for tuned mass dampers in isolated structures is presented. The proposed optimization method is specifically developed to control base displacements or to solve the large isolator displacement problem in this type of structures under earthquakes. Therefore, it is based on a displacement transmissibility function, T, a particular case of the general transmissibility concept, which comes from Vibration Isolation. Three contributions are: 1) application of new seismic displacement narrowbandness, 2) simpler relative transmissibility function, and 3) compound design of isolation plus tuned mass damper. A standard isolated model is used to show that the base displacement can be controlled at levels in the proximity of the ground motion (T ≈ 1), which results in a positive comparison with previous isolation plus tuned mass damper solutions; this is one of the main conclusions and it is based on novelty 3 above; in fact, other solutions in the literature compare their attained displacements with respect to the structure without tuned mass damper. Comparison with isolated results is not, therefore, possible herein, but it is not desirable either; actually, what is possible is a positive and more demanding comparison, which is with respect to the very seismic ground displacement itself. The large isolator displacement problem can be solved or attenuated by properly designing a tuned mass damper subsystem jointly with the isolation one.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).