Exactitud y precisión a nivel de laboratorio en la determinación de au en minerales mediante bomba calorimétrica a partir del concentrado de carbón activado.
Descripción del Articulo
The present work of Investigation, it was based on a reaction of combustion using a calorimeter type bomb to separate Gold of a concentrate with activated coal. The aim is to determine the accuracy and precision of the method of combustion in the bomb calorimetric after the process of cianuración, a...
Autores: | , |
---|---|
Formato: | tesis de grado |
Fecha de Publicación: | 2012 |
Institución: | Universidad Nacional de Trujillo |
Repositorio: | UNITRU-Tesis |
Lenguaje: | español |
OAI Identifier: | oai:dspace.unitru.edu.pe:20.500.14414/3369 |
Enlace del recurso: | https://hdl.handle.net/20.500.14414/3369 |
Nivel de acceso: | acceso abierto |
Materia: | Determinación de au en minerales, Bomba calorimétrica, Concentrado de carbón activado. |
id |
UNIT_afda3e8496f6192dd91d49fdd68bae38 |
---|---|
oai_identifier_str |
oai:dspace.unitru.edu.pe:20.500.14414/3369 |
network_acronym_str |
UNIT |
network_name_str |
UNITRU-Tesis |
repository_id_str |
4801 |
dc.title.es_ES.fl_str_mv |
Exactitud y precisión a nivel de laboratorio en la determinación de au en minerales mediante bomba calorimétrica a partir del concentrado de carbón activado. |
title |
Exactitud y precisión a nivel de laboratorio en la determinación de au en minerales mediante bomba calorimétrica a partir del concentrado de carbón activado. |
spellingShingle |
Exactitud y precisión a nivel de laboratorio en la determinación de au en minerales mediante bomba calorimétrica a partir del concentrado de carbón activado. González Mendoza, Rita Jeanette Determinación de au en minerales, Bomba calorimétrica, Concentrado de carbón activado. |
title_short |
Exactitud y precisión a nivel de laboratorio en la determinación de au en minerales mediante bomba calorimétrica a partir del concentrado de carbón activado. |
title_full |
Exactitud y precisión a nivel de laboratorio en la determinación de au en minerales mediante bomba calorimétrica a partir del concentrado de carbón activado. |
title_fullStr |
Exactitud y precisión a nivel de laboratorio en la determinación de au en minerales mediante bomba calorimétrica a partir del concentrado de carbón activado. |
title_full_unstemmed |
Exactitud y precisión a nivel de laboratorio en la determinación de au en minerales mediante bomba calorimétrica a partir del concentrado de carbón activado. |
title_sort |
Exactitud y precisión a nivel de laboratorio en la determinación de au en minerales mediante bomba calorimétrica a partir del concentrado de carbón activado. |
author |
González Mendoza, Rita Jeanette |
author_facet |
González Mendoza, Rita Jeanette Lostaunau Ardiles, Luis Alberto |
author_role |
author |
author2 |
Lostaunau Ardiles, Luis Alberto |
author2_role |
author |
dc.contributor.advisor.fl_str_mv |
Costilla Sánchez, Noé |
dc.contributor.author.fl_str_mv |
González Mendoza, Rita Jeanette Lostaunau Ardiles, Luis Alberto |
dc.subject.es_ES.fl_str_mv |
Determinación de au en minerales, Bomba calorimétrica, Concentrado de carbón activado. |
topic |
Determinación de au en minerales, Bomba calorimétrica, Concentrado de carbón activado. |
description |
The present work of Investigation, it was based on a reaction of combustion using a calorimeter type bomb to separate Gold of a concentrate with activated coal. The aim is to determine the accuracy and precision of the method of combustion in the bomb calorimetric after the process of cianuración, absorption with activated coal and his later quantification for atomic absorption, demonstrating so by this method the major recovery of Gold is obtained. For the fulfillment of our aims, it was necessary to work with golden boss's diverse standards which were injected to a gram of coal approximately, and one took to combustion the sample. After obtained the sample combustion totally, the residues that stay remove to digestar using royal water, we dilute with nitric acid 1 % for his later reading in the equipment of Atomic Absorption and to obtain the golden concentration. The experimental procedure repeated three times to execute the statistical evaluation as the standard diversion and the coefficient of variation and it could determine the accuracy and precision of the method in the golden determination by means of combustion in the bomb calorimetric. The concentrations of the standards were of 0.08, 0.10 and 0.12 ppm having a recovery of 0.0785, 0.0986, 0.1185 ppm, respectively. |
publishDate |
2012 |
dc.date.accessioned.none.fl_str_mv |
2016-10-14T03:24:33Z |
dc.date.available.none.fl_str_mv |
2016-10-14T03:24:33Z |
dc.date.issued.fl_str_mv |
2012 |
dc.type.es_ES.fl_str_mv |
info:eu-repo/semantics/bachelorThesis |
format |
bachelorThesis |
dc.identifier.uri.none.fl_str_mv |
https://hdl.handle.net/20.500.14414/3369 |
url |
https://hdl.handle.net/20.500.14414/3369 |
dc.language.iso.es_ES.fl_str_mv |
spa |
language |
spa |
dc.relation.ispartof.fl_str_mv |
SUNEDU |
dc.rights.es_ES.fl_str_mv |
info:eu-repo/semantics/openAccess |
dc.rights.uri.none.fl_str_mv |
http://creativecommons.org/licenses/by-nc-nd/2.5/pe/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
http://creativecommons.org/licenses/by-nc-nd/2.5/pe/ |
dc.publisher.es_ES.fl_str_mv |
Universidad Nacional de Trujillo |
dc.source.es_ES.fl_str_mv |
Universidad Nacional de Trujillo Repositorio institucional - UNITRU |
dc.source.none.fl_str_mv |
reponame:UNITRU-Tesis instname:Universidad Nacional de Trujillo instacron:UNITRU |
instname_str |
Universidad Nacional de Trujillo |
instacron_str |
UNITRU |
institution |
UNITRU |
reponame_str |
UNITRU-Tesis |
collection |
UNITRU-Tesis |
bitstream.url.fl_str_mv |
https://dspace.unitru.edu.pe/bitstreams/682a3555-f88b-486b-9300-fa4b44453dd1/download https://dspace.unitru.edu.pe/bitstreams/033f0839-150b-4688-a19c-c693343e00ad/download |
bitstream.checksum.fl_str_mv |
d9e11368c371fd61dd099beea8e732be 8a4605be74aa9ea9d79846c1fba20a33 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
repository.name.fl_str_mv |
Repositorio Institucional - UNITRU |
repository.mail.fl_str_mv |
repositorios@unitru.edu.pe |
_version_ |
1807290171214790656 |
spelling |
Costilla Sánchez, NoéGonzález Mendoza, Rita JeanetteLostaunau Ardiles, Luis Alberto2016-10-14T03:24:33Z2016-10-14T03:24:33Z2012https://hdl.handle.net/20.500.14414/3369The present work of Investigation, it was based on a reaction of combustion using a calorimeter type bomb to separate Gold of a concentrate with activated coal. The aim is to determine the accuracy and precision of the method of combustion in the bomb calorimetric after the process of cianuración, absorption with activated coal and his later quantification for atomic absorption, demonstrating so by this method the major recovery of Gold is obtained. For the fulfillment of our aims, it was necessary to work with golden boss's diverse standards which were injected to a gram of coal approximately, and one took to combustion the sample. After obtained the sample combustion totally, the residues that stay remove to digestar using royal water, we dilute with nitric acid 1 % for his later reading in the equipment of Atomic Absorption and to obtain the golden concentration. The experimental procedure repeated three times to execute the statistical evaluation as the standard diversion and the coefficient of variation and it could determine the accuracy and precision of the method in the golden determination by means of combustion in the bomb calorimetric. The concentrations of the standards were of 0.08, 0.10 and 0.12 ppm having a recovery of 0.0785, 0.0986, 0.1185 ppm, respectively.El presente trabajo de Investigación, se basó en una reacción de combustión empleando un calorímetro tipo bomba para separar Oro de un concentrado con carbón activado. El objetivo es determinar la exactitud y precisión del método de combustión en la bomba calorimétrica después del proceso de cianuración, absorción con carbón activado y su posterior cuantificación por absorción atómica, demostrando así que por este método se obtiene la mayor recuperación de Oro. Para el cumplimiento de nuestros objetivos, fue necesario trabajar con diversos estándares de patrón de Oro los cuales fueron inyectados aun gramo de carbón aproximadamente, y se llevó a combustión la muestra. Luego de obtenida la muestra totalmente combustionada, los residuos que quedan se llevan a digestar empleando agua regia, diluimos con ácido nítrico al 1% para su posterior lectura en el equipo de Absorción Atómica y obtener la concentración de Oro. Se repitió el procedimiento experimental tres veces para ejecutar la evaluación estadística como la desviación estándar y el coeficiente de variación y se pueda determinar la exactitud y precisión del método en la determinación de Oro mediante combustión en la bomba calorimétrica. Las concentraciones de los estándares fueron de 0.08, 0.10 y 0.12 ppm teniendo una recuperación de 0.0785, 0.0986, 0.1185 ppm, respectivamente.spaUniversidad Nacional de Trujilloinfo:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-nd/2.5/pe/Universidad Nacional de TrujilloRepositorio institucional - UNITRUreponame:UNITRU-Tesisinstname:Universidad Nacional de Trujilloinstacron:UNITRUDeterminación de au en minerales, Bomba calorimétrica, Concentrado de carbón activado.Exactitud y precisión a nivel de laboratorio en la determinación de au en minerales mediante bomba calorimétrica a partir del concentrado de carbón activado.info:eu-repo/semantics/bachelorThesisSUNEDUTítulo ProfesionalIngeniero QuímicoIngenieria QuímicaUniversidad Nacional de Trujillo.Facultad de Ingeniería QuímicaORIGINALGonzalezMendoza_R - LostaunauArdiles_L.pdfGonzalezMendoza_R - LostaunauArdiles_L.pdfBachiller en Ingeniería Químicaapplication/pdf1744376https://dspace.unitru.edu.pe/bitstreams/682a3555-f88b-486b-9300-fa4b44453dd1/downloadd9e11368c371fd61dd099beea8e732beMD51LICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://dspace.unitru.edu.pe/bitstreams/033f0839-150b-4688-a19c-c693343e00ad/download8a4605be74aa9ea9d79846c1fba20a33MD5220.500.14414/3369oai:dspace.unitru.edu.pe:20.500.14414/33692017-11-15 12:18:38.867http://creativecommons.org/licenses/by-nc-nd/2.5/pe/info:eu-repo/semantics/openAccessopen.accesshttps://dspace.unitru.edu.peRepositorio Institucional - UNITRUrepositorios@unitru.edu.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 |
score |
13.982926 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).