Control fisicoquímico de Clorfenamina 4 mg tabletas realizado en el laboratorio HYPATIA S.A., Lima, 2016 - 2017

Descripción del Articulo

The present report of pre-professional practices was aimed at performing the physico-chemical control of Chlorphenamine 4 mg tablets in the laboratory HYPATIA S.A. The sample consisted of 5 different batches of 200 tablets each, using a simple random sampling technique, obtained from a pharmaceutica...

Descripción completa

Detalles Bibliográficos
Autor: Burgos Aguilar, Martha Paola
Formato: tesis de grado
Fecha de Publicación:2017
Institución:Universidad Nacional de Trujillo
Repositorio:UNITRU-Tesis
Lenguaje:español
OAI Identifier:oai:dspace.unitru.edu.pe:20.500.14414/8934
Enlace del recurso:https://hdl.handle.net/20.500.14414/8934
Nivel de acceso:acceso abierto
Materia:Clorfenamina, control fisicoquímico, conformidad
id UNIT_5c72e1585142626933204800a9aaf37f
oai_identifier_str oai:dspace.unitru.edu.pe:20.500.14414/8934
network_acronym_str UNIT
network_name_str UNITRU-Tesis
repository_id_str 4801
dc.title.es_PE.fl_str_mv Control fisicoquímico de Clorfenamina 4 mg tabletas realizado en el laboratorio HYPATIA S.A., Lima, 2016 - 2017
title Control fisicoquímico de Clorfenamina 4 mg tabletas realizado en el laboratorio HYPATIA S.A., Lima, 2016 - 2017
spellingShingle Control fisicoquímico de Clorfenamina 4 mg tabletas realizado en el laboratorio HYPATIA S.A., Lima, 2016 - 2017
Burgos Aguilar, Martha Paola
Clorfenamina, control fisicoquímico, conformidad
title_short Control fisicoquímico de Clorfenamina 4 mg tabletas realizado en el laboratorio HYPATIA S.A., Lima, 2016 - 2017
title_full Control fisicoquímico de Clorfenamina 4 mg tabletas realizado en el laboratorio HYPATIA S.A., Lima, 2016 - 2017
title_fullStr Control fisicoquímico de Clorfenamina 4 mg tabletas realizado en el laboratorio HYPATIA S.A., Lima, 2016 - 2017
title_full_unstemmed Control fisicoquímico de Clorfenamina 4 mg tabletas realizado en el laboratorio HYPATIA S.A., Lima, 2016 - 2017
title_sort Control fisicoquímico de Clorfenamina 4 mg tabletas realizado en el laboratorio HYPATIA S.A., Lima, 2016 - 2017
author Burgos Aguilar, Martha Paola
author_facet Burgos Aguilar, Martha Paola
author_role author
dc.contributor.advisor.fl_str_mv Rengifo Penadillos, Roger Antonio
dc.contributor.author.fl_str_mv Burgos Aguilar, Martha Paola
dc.subject.es_PE.fl_str_mv Clorfenamina, control fisicoquímico, conformidad
topic Clorfenamina, control fisicoquímico, conformidad
description The present report of pre-professional practices was aimed at performing the physico-chemical control of Chlorphenamine 4 mg tablets in the laboratory HYPATIA S.A. The sample consisted of 5 different batches of 200 tablets each, using a simple random sampling technique, obtained from a pharmaceutical industry, which were delivered to the counter sample area to be derived to the area of physicochemistry for its corresponding analysis. The results obtained from the analyzes were: appearance, round shaped tablet with central groove on one of its sides. Orange color with whitish and more intense orange color scores; for the mass uniformity test, resulting in 182.14 mg / tab; solution with 98.28%; content with a percentage of 102.3% and uniformity of content with a percentage of 6.84% (AV); the results obtained were within the values established by the official standard USP 39 and the technical standard of laboratory of origin. It is concluded that Chlorphenamine 4 mg Tablets comply with the specifications set forth by USP 39 and the technical standard of the laboratory of origin
publishDate 2017
dc.date.accessioned.none.fl_str_mv 2017-10-17T17:15:04Z
dc.date.available.none.fl_str_mv 2017-10-17T17:15:04Z
dc.date.issued.fl_str_mv 2017-09
dc.type.es_PE.fl_str_mv info:eu-repo/semantics/bachelorThesis
format bachelorThesis
dc.identifier.uri.none.fl_str_mv https://hdl.handle.net/20.500.14414/8934
url https://hdl.handle.net/20.500.14414/8934
dc.language.iso.es_PE.fl_str_mv spa
language spa
dc.relation.ispartof.fl_str_mv SUNEDU
dc.rights.es_PE.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.uri.es_PE.fl_str_mv http://creativecommons.org/licenses/by-nc-nd/2.5/pe/
eu_rights_str_mv openAccess
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-nd/2.5/pe/
dc.publisher.es_PE.fl_str_mv Universidad Nacional de Trujillo
dc.source.es_PE.fl_str_mv Universidad Nacional de Trujillo
Repositorio institucional - UNITRU
dc.source.none.fl_str_mv reponame:UNITRU-Tesis
instname:Universidad Nacional de Trujillo
instacron:UNITRU
instname_str Universidad Nacional de Trujillo
instacron_str UNITRU
institution UNITRU
reponame_str UNITRU-Tesis
collection UNITRU-Tesis
bitstream.url.fl_str_mv https://dspace.unitru.edu.pe/bitstreams/1982324c-a3fd-45c0-b763-67a6157c547e/download
https://dspace.unitru.edu.pe/bitstreams/193c8af9-291c-48f2-be83-dacf95ef17be/download
bitstream.checksum.fl_str_mv 8e765f41d6afe1b76402a4b9b7841efb
8a4605be74aa9ea9d79846c1fba20a33
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Repositorio Institucional - UNITRU
repository.mail.fl_str_mv repositorios@unitru.edu.pe
_version_ 1807290087893893120
spelling Rengifo Penadillos, Roger AntonioBurgos Aguilar, Martha Paola2017-10-17T17:15:04Z2017-10-17T17:15:04Z2017-09https://hdl.handle.net/20.500.14414/8934The present report of pre-professional practices was aimed at performing the physico-chemical control of Chlorphenamine 4 mg tablets in the laboratory HYPATIA S.A. The sample consisted of 5 different batches of 200 tablets each, using a simple random sampling technique, obtained from a pharmaceutical industry, which were delivered to the counter sample area to be derived to the area of physicochemistry for its corresponding analysis. The results obtained from the analyzes were: appearance, round shaped tablet with central groove on one of its sides. Orange color with whitish and more intense orange color scores; for the mass uniformity test, resulting in 182.14 mg / tab; solution with 98.28%; content with a percentage of 102.3% and uniformity of content with a percentage of 6.84% (AV); the results obtained were within the values established by the official standard USP 39 and the technical standard of laboratory of origin. It is concluded that Chlorphenamine 4 mg Tablets comply with the specifications set forth by USP 39 and the technical standard of the laboratory of originEl presente informe de prácticas pre-profesionales tuvo como finalidad realizar el control fisicoquímico de Clorfenamina 4 mg tabletas en el laboratorio HYPATIA S.A. La muestra estuvo conformada por 5 lotes diferentes de 200 tabletas cada uno, utilizando como técnica de muestreo simple aleatorio, obtenidas de una industria farmacéutica, las cuales fueron entregadas al área de contramuestra para ser derivadas al área de fisicoquímica para su análisis correspondiente. Los resultados que se obtuvieron de los análisis realizados fueron: aspecto, tableta de forma redonda con ranura central en uno de sus lados. Color anaranjado con puntuaciones blanquecinas y de color anaranjado más intenso; para el ensayo de uniformidad de masa, teniendo como resultado 182,14 mg/tab.; disolución con un porcentaje de 98,228%; contenido con un porcentaje de 102,3% y uniformidad de contenido con un porcentaje de 6,84% (AV); los resultados obtenidos estuvieron dentro de los valores establecidos por la norma oficial USP 39 y la norma técnica de laboratorio de origen. Se concluye que Clorfenamina 4 mg Tabletas cumple con las especificaciones consignadas por la USP 39 y la norma técnica del laboratorio de origenTesisspaUniversidad Nacional de Trujilloinfo:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-nd/2.5/pe/Universidad Nacional de TrujilloRepositorio institucional - UNITRUreponame:UNITRU-Tesisinstname:Universidad Nacional de Trujilloinstacron:UNITRUClorfenamina, control fisicoquímico, conformidadControl fisicoquímico de Clorfenamina 4 mg tabletas realizado en el laboratorio HYPATIA S.A., Lima, 2016 - 2017info:eu-repo/semantics/bachelorThesisSUNEDUTítulo ProfesionalQuímico FarmacéuticoFarmaciaUniversidad Nacional de Trujillo.Facultad de Farmacia y BIoquímicaORIGINALBurgos Aguilar Martha Paola.pdfBurgos Aguilar Martha Paola.pdfapplication/pdf1015553https://dspace.unitru.edu.pe/bitstreams/1982324c-a3fd-45c0-b763-67a6157c547e/download8e765f41d6afe1b76402a4b9b7841efbMD51LICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://dspace.unitru.edu.pe/bitstreams/193c8af9-291c-48f2-be83-dacf95ef17be/download8a4605be74aa9ea9d79846c1fba20a33MD5220.500.14414/8934oai:dspace.unitru.edu.pe:20.500.14414/89342017-11-15 12:18:36.436http://creativecommons.org/licenses/by-nc-nd/2.5/pe/info:eu-repo/semantics/openAccessopen.accesshttps://dspace.unitru.edu.peRepositorio Institucional - UNITRUrepositorios@unitru.edu.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
score 13.876876
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).