Control fisicoquímico de Clorfenamina 4 mg tabletas realizado en el laboratorio HYPATIA S.A., Lima, 2016 - 2017
Descripción del Articulo
The present report of pre-professional practices was aimed at performing the physico-chemical control of Chlorphenamine 4 mg tablets in the laboratory HYPATIA S.A. The sample consisted of 5 different batches of 200 tablets each, using a simple random sampling technique, obtained from a pharmaceutica...
Autor: | |
---|---|
Formato: | tesis de grado |
Fecha de Publicación: | 2017 |
Institución: | Universidad Nacional de Trujillo |
Repositorio: | UNITRU-Tesis |
Lenguaje: | español |
OAI Identifier: | oai:dspace.unitru.edu.pe:20.500.14414/8934 |
Enlace del recurso: | https://hdl.handle.net/20.500.14414/8934 |
Nivel de acceso: | acceso abierto |
Materia: | Clorfenamina, control fisicoquímico, conformidad |
Sumario: | The present report of pre-professional practices was aimed at performing the physico-chemical control of Chlorphenamine 4 mg tablets in the laboratory HYPATIA S.A. The sample consisted of 5 different batches of 200 tablets each, using a simple random sampling technique, obtained from a pharmaceutical industry, which were delivered to the counter sample area to be derived to the area of physicochemistry for its corresponding analysis. The results obtained from the analyzes were: appearance, round shaped tablet with central groove on one of its sides. Orange color with whitish and more intense orange color scores; for the mass uniformity test, resulting in 182.14 mg / tab; solution with 98.28%; content with a percentage of 102.3% and uniformity of content with a percentage of 6.84% (AV); the results obtained were within the values established by the official standard USP 39 and the technical standard of laboratory of origin. It is concluded that Chlorphenamine 4 mg Tablets comply with the specifications set forth by USP 39 and the technical standard of the laboratory of origin |
---|
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).