Influencia de la posición del sensor MQ-6 y el tiempo transcurrido en la detección de concentración de GLP en una fuga doméstica
Descripción del Articulo
Gas leaks in Lima and Ica (Peru) increase every year, causing accidents and irreparable damage to the population. In this article, a controlled leak was produced using a two-burner kitchen and an array of MQ-6 sensors positioned at different angles (45°, 0° and 30°) with respect to the kitchen. The...
Autores: | , |
---|---|
Formato: | tesis de grado |
Fecha de Publicación: | 2023 |
Institución: | Universidad de Lima |
Repositorio: | ULIMA-Institucional |
Lenguaje: | español |
OAI Identifier: | oai:repositorio.ulima.edu.pe:20.500.12724/19409 |
Enlace del recurso: | https://hdl.handle.net/20.500.12724/19409 |
Nivel de acceso: | acceso abierto |
Materia: | Sensors Liquefied petroleum gas Sensores Gas licuado de petróleo https://purl.org/pe-repo/ocde/ford#2.11.04 |
Sumario: | Gas leaks in Lima and Ica (Peru) increase every year, causing accidents and irreparable damage to the population. In this article, a controlled leak was produced using a two-burner kitchen and an array of MQ-6 sensors positioned at different angles (45°, 0° and 30°) with respect to the kitchen. The results show that, if the kitchen is in a high position (87 cm), the detected concentration is lower, but the detection is faster (6.419 s) if the arrangement is located 50 cm from the origin of the leak. The detection time is between 13,515 s and 21,740 s and the maximum concentration detected is 98 ppm. The best adapted learning model is Suport Vector Machine, with an RMSE of 4,61 ppm. It is concluded that the best position for gas detection was at a height of 47 cm above the ground, at 50 cm from the sensor and at an angle of 0°. The detection time is 13.84 s. Finally, it is concluded that 30 seconds of leakage are not enough to reach the harmfull limit (147 ppm). |
---|
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).