Meteorological conditions and particulate material PM10 and PM2.5 in the construction of the hospital Hipólito Unánue, Tacna 2019

Descripción del Articulo

The study was based on the influence of meteorological conditions on the dispersion of PM10 and PM2.5 atmospheric pollutants during the construction of Hipólito Unánue Hospital in Tacna from June to September 2018. The sampling methodology and analysis was based on the DIGESA air quality monitoring...

Descripción completa

Detalles Bibliográficos
Autores: Motocanche Ayala, Diego, Lazo Ramos, Richard Sabino
Formato: artículo
Fecha de Publicación:2020
Institución:Universidad Privada de Tacna
Repositorio:Revistas - Universidad Privada de Tacna
Lenguaje:español
OAI Identifier:oai:revistas.upt.edu.pe:article/297
Enlace del recurso:https://revistas.upt.edu.pe/ojs/index.php/ingenieria/article/view/297
Nivel de acceso:acceso abierto
Materia:Condiciones meteorológicas
Dispersión de Contaminantes
Material particulado
Meteorological conditions
Pollutant dispersion
Particulate matter
id REVUPT_b46a905e359685a7f8049a26dd865f76
oai_identifier_str oai:revistas.upt.edu.pe:article/297
network_acronym_str REVUPT
network_name_str Revistas - Universidad Privada de Tacna
repository_id_str
spelling Meteorological conditions and particulate material PM10 and PM2.5 in the construction of the hospital Hipólito Unánue, Tacna 2019Condiciones meteorológicas y material particulado PM10 y PM2.5 en la construcción del hospital Hipólito Unánue, Tacna 2019Motocanche Ayala, DiegoLazo Ramos, Richard SabinoCondiciones meteorológicasDispersión de ContaminantesMaterial particuladoMeteorological conditionsPollutant dispersionParticulate matterThe study was based on the influence of meteorological conditions on the dispersion of PM10 and PM2.5 atmospheric pollutants during the construction of Hipólito Unánue Hospital in Tacna from June to September 2018. The sampling methodology and analysis was based on the DIGESA air quality monitoring and data management protocol (2005). The 2 monitoring stations EMHU-01 and EMHU-02 registered in the month of June for PM2.5 values of 69.53 and 63.04 ug/m3 and in the month of September in the station EMHU-01 the value of 64.40 ug/m3 which exceeded the environmental quality standard for air. These values were directly related to the high temperature values of 18 and 19.6 °C and the wind speed of 2.5 m/s and an inverse relationship with the relative humidity of 76.3 and 75%. In addition, the analysis of the variance determined that there is no significant difference between the data obtained and both variables were corroborated with the Pearson statistical test (r) 0.705, the correlation coefficient p-value (sig = 0.016) and with a level of significance less than 0.05El presente estudio se basó en la influencia de las condiciones meteorológicas en la dispersión de la concentración de los contaminantes atmosféricos PM10 y PM2.5 durante la construcción del Hospital Hipólito Unánue de Tacna en los meses de junio a setiembre de 2018. La metodología de muestreo y análisis estuvo basado en el protocolo de monitoreo de calidad de aire y gestión de datos de la DIGESA (2005). Las 2 estaciones de monitoreo EMHU-01 y EMHU-02 registraron en el mes de junio para PM2.5 valores de 69.53 y 63,04 ug/m3 y en el mes de setiembre en la estación EMHU-01 el valor de 64,40 ug/m3 los cuales sobrepasaron el estándar de calidad ambiental para aire. Estos valores tuvieron relación directa con los altos valores de Temperatura de 18 y 19,6 °C y la velocidad de viento de 2,5 m/s y una relación inversa con la Humedad relativa 76,3 y 75 %. Además se determinó q no existe relación significativa entre los datos obtenidos y ambas variables fueron corroboradas con la prueba estadística chi cuadrado de PearsonUNIVERSIDAD PRIVADA DE TACNA2020-07-14info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistas.upt.edu.pe/ojs/index.php/ingenieria/article/view/29710.47796/ing.v2i01.297INGENIERÍA INVESTIGA; Vol. 2 No. 01 (2020): Ingeniería Investiga; pp. 276 - 285INGENIERÍA INVESTIGA; Vol. 2 Núm. 01 (2020): Ingeniería Investiga; pp. 276 - 2852708-303910.47796/ing.v2i01reponame:Revistas - Universidad Privada de Tacnainstname:Universidad Privada de Tacnainstacron:UPTspahttps://revistas.upt.edu.pe/ojs/index.php/ingenieria/article/view/297/268info:eu-repo/semantics/openAccessoai:revistas.upt.edu.pe:article/2972021-11-29T10:39:55Z
dc.title.none.fl_str_mv Meteorological conditions and particulate material PM10 and PM2.5 in the construction of the hospital Hipólito Unánue, Tacna 2019
Condiciones meteorológicas y material particulado PM10 y PM2.5 en la construcción del hospital Hipólito Unánue, Tacna 2019
title Meteorological conditions and particulate material PM10 and PM2.5 in the construction of the hospital Hipólito Unánue, Tacna 2019
spellingShingle Meteorological conditions and particulate material PM10 and PM2.5 in the construction of the hospital Hipólito Unánue, Tacna 2019
Motocanche Ayala, Diego
Condiciones meteorológicas
Dispersión de Contaminantes
Material particulado
Meteorological conditions
Pollutant dispersion
Particulate matter
title_short Meteorological conditions and particulate material PM10 and PM2.5 in the construction of the hospital Hipólito Unánue, Tacna 2019
title_full Meteorological conditions and particulate material PM10 and PM2.5 in the construction of the hospital Hipólito Unánue, Tacna 2019
title_fullStr Meteorological conditions and particulate material PM10 and PM2.5 in the construction of the hospital Hipólito Unánue, Tacna 2019
title_full_unstemmed Meteorological conditions and particulate material PM10 and PM2.5 in the construction of the hospital Hipólito Unánue, Tacna 2019
title_sort Meteorological conditions and particulate material PM10 and PM2.5 in the construction of the hospital Hipólito Unánue, Tacna 2019
dc.creator.none.fl_str_mv Motocanche Ayala, Diego
Lazo Ramos, Richard Sabino
author Motocanche Ayala, Diego
author_facet Motocanche Ayala, Diego
Lazo Ramos, Richard Sabino
author_role author
author2 Lazo Ramos, Richard Sabino
author2_role author
dc.subject.none.fl_str_mv Condiciones meteorológicas
Dispersión de Contaminantes
Material particulado
Meteorological conditions
Pollutant dispersion
Particulate matter
topic Condiciones meteorológicas
Dispersión de Contaminantes
Material particulado
Meteorological conditions
Pollutant dispersion
Particulate matter
description The study was based on the influence of meteorological conditions on the dispersion of PM10 and PM2.5 atmospheric pollutants during the construction of Hipólito Unánue Hospital in Tacna from June to September 2018. The sampling methodology and analysis was based on the DIGESA air quality monitoring and data management protocol (2005). The 2 monitoring stations EMHU-01 and EMHU-02 registered in the month of June for PM2.5 values of 69.53 and 63.04 ug/m3 and in the month of September in the station EMHU-01 the value of 64.40 ug/m3 which exceeded the environmental quality standard for air. These values were directly related to the high temperature values of 18 and 19.6 °C and the wind speed of 2.5 m/s and an inverse relationship with the relative humidity of 76.3 and 75%. In addition, the analysis of the variance determined that there is no significant difference between the data obtained and both variables were corroborated with the Pearson statistical test (r) 0.705, the correlation coefficient p-value (sig = 0.016) and with a level of significance less than 0.05
publishDate 2020
dc.date.none.fl_str_mv 2020-07-14
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://revistas.upt.edu.pe/ojs/index.php/ingenieria/article/view/297
10.47796/ing.v2i01.297
url https://revistas.upt.edu.pe/ojs/index.php/ingenieria/article/view/297
identifier_str_mv 10.47796/ing.v2i01.297
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv https://revistas.upt.edu.pe/ojs/index.php/ingenieria/article/view/297/268
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv UNIVERSIDAD PRIVADA DE TACNA
publisher.none.fl_str_mv UNIVERSIDAD PRIVADA DE TACNA
dc.source.none.fl_str_mv INGENIERÍA INVESTIGA; Vol. 2 No. 01 (2020): Ingeniería Investiga; pp. 276 - 285
INGENIERÍA INVESTIGA; Vol. 2 Núm. 01 (2020): Ingeniería Investiga; pp. 276 - 285
2708-3039
10.47796/ing.v2i01
reponame:Revistas - Universidad Privada de Tacna
instname:Universidad Privada de Tacna
instacron:UPT
instname_str Universidad Privada de Tacna
instacron_str UPT
institution UPT
reponame_str Revistas - Universidad Privada de Tacna
collection Revistas - Universidad Privada de Tacna
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1853133655560421376
score 12.892405
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).