In vitro antimicrobial activity of 3MIX-MP and CTZ pastes against Enterococcus faecalis ATCC® 29212

Descripción del Articulo

Objective. To determine the antibacterial effect of triantibiotic paste (3MIX-MP) and chloramphenicol-tetracycline-ZOE (CTZ) antibiotic paste at 24, 48, 72 hours and 7 days on Enterococcus faecalis. Methods. Experimental, in vitro, comparative study, with a non-probabilistic sample for convenience o...

Descripción completa

Detalles Bibliográficos
Autores: Vargas-Mendoza, Jesús Antonio, Mamani-Quispe, Rosini Alicia, Mercado-Portal, Jorge Luis, Aguilar-Vilca, Abel Josue, Padilla-Cáceres, Tania Carola
Formato: artículo
Fecha de Publicación:2023
Institución:Universidad Nacional Mayor de San Marcos
Repositorio:Revistas - Universidad Nacional Mayor de San Marcos
Lenguaje:español
OAI Identifier:oai:ojs.csi.unmsm:article/23182
Enlace del recurso:https://revistasinvestigacion.unmsm.edu.pe/index.php/odont/article/view/23182
Nivel de acceso:acceso abierto
Materia:Antimicrobials
Pulpotomy
Enterococcus faecalis
Pediatric dentistry
Antimicrobianos
Pulpotomía
Odontología pediátrica
Descripción
Sumario:Objective. To determine the antibacterial effect of triantibiotic paste (3MIX-MP) and chloramphenicol-tetracycline-ZOE (CTZ) antibiotic paste at 24, 48, 72 hours and 7 days on Enterococcus faecalis. Methods. Experimental, in vitro, comparative study, with a non-probabilistic sample for convenience of 210 paper discs, distributed in 30 Petri dishes previously prepared with Mitis Salivarius agar and Mueller Hinton agar and inoculated with strains of Enterococcus faecalis ATCC® 29212. The method was used. Kirby-Bauer, inoculated with a 0.5 McFarland suspension of Enterococcus faecalis. Filter paper discs were placed inside the wells and 10 µl of antimicrobial pastes and control were supplied. The positive control was zinc oxide-eugenol cement discs; halo diameters were measured with a vernier caliper. A repeated measures ANOVA was used for intragroup comparisons, one-way ANOVA for intergroup comparisons, and Tukey’s post hoc tests. Results. After 24 hours, the 3MIX-MP paste obtained larger inhibition zone diameters than the CTZ paste with an average of 39,24 mm and 34,19 mm, respectively, and a minimum of 36,26 mm and 26,38 mm at 24 hours. 7 days. Statistically significant differences were observed between the halos obtained from the 3MIX-MP paste and the CTZ paste, except for the control after 48 hours. Conclusions. It was determined that the 3MIX-MP paste has a greater inhibitory action in vitro compared to the CTZ paste, the diameter of the inhibitory halos decreased as the exposure time to the microorganism increased.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).