Value Tilt Test Sensitized with Isosorbide Dinitrate Sublingual 5 mg in Patients with Recurrent Syncope Departure Not Determined

Descripción del Articulo

OBJECTIVE : Sign in our study of recurrent syncope of undetermined origin employing Tilt Test (PI) sensitized with isosorbide dinitrate (ISB) . MATERIAL AND METHODS : Prospective study of patients with recurrent syncope , hedge 1995 - 1996 hedge at the Naval Medical Center , using the PI (80° for 25...

Descripción completa

Detalles Bibliográficos
Autores: Yanac, Pedro, Tapia, Pedro
Formato: artículo
Fecha de Publicación:1998
Institución:Universidad Nacional Mayor de San Marcos
Repositorio:Revistas - Universidad Nacional Mayor de San Marcos
Lenguaje:español
OAI Identifier:oai:ojs.csi.unmsm:article/4630
Enlace del recurso:https://revistasinvestigacion.unmsm.edu.pe/index.php/anales/article/view/4630
Nivel de acceso:acceso abierto
Materia:Síncope
Hipotensión Controlada
Dinitrato de lsosorbide
Hipotensión Ortostática
Syncope
Controlled Hypotension
dinitrate lsosorbide
Orthostatic Hypotension
Descripción
Sumario:OBJECTIVE : Sign in our study of recurrent syncope of undetermined origin employing Tilt Test (PI) sensitized with isosorbide dinitrate (ISB) . MATERIAL AND METHODS : Prospective study of patients with recurrent syncope , hedge 1995 - 1996 hedge at the Naval Medical Center , using the PI (80° for 25 min) . If you tested negative , was repeated but with ISB 5 mg SL. The same protocol was performed in patients without a history of syncope. RESULTS : 23 patients were studied. In the baseline test , 4 (17%) tested positive , at 19 (83%) were negative ISB stimulated with 5 mg SL : 10 patients had positive response (43% of total). Only one patient had side effects ( severe headache) . Only one control subject (8 %) had PI (+) after the administration of ISB. Most patients (64 %) were under 40 years. The frequency of positive tests going and specificity of the test with ISU SL is 60 % and 92 % , respectively. CONCLUSIONS: PI stimulated ISB has good sensitivity , specificity and positive predictive value is comparable to stimulation with isoproterenol, which is the technique used, and is quick and simple. We recommend its routine use in the diagnosis of recurrent syncope of undetermined origin .
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).