RATING PHARMACEUTICAL EQUIVALENCE in vitro BY HPLC METHODOLOGY FOUR DRUGS CONTAINING ACETAMINOPHEN, CHLORPHENIRAMINE MALEATE AND PHENYLEPHRINE HYDROCHLORIDE TABLETS

Descripción del Articulo

Pharmaceutical equivalence in vitro four medicines containing paracetamol, maleate chlorpheniramine and phenylephrine hydrochloride tablets using Chromatography Liquid High Resolution reversed phase (HPLC-RP) is called, the dissolution profiles of the reference product and were determined 4 products...

Descripción completa

Detalles Bibliográficos
Autores: Samaniego Joaquin, Jhonnel, Arias Arroyo, Gladys
Formato: artículo
Fecha de Publicación:2016
Institución:Sociedad Química del Perú
Repositorio:Revista de la Sociedad Química del Perú
Lenguaje:español
OAI Identifier:oai:rsqp.revistas.sqperu.org.pe:article/132
Enlace del recurso:http://revistas.sqperu.org.pe/index.php/revistasqperu/article/view/132
Nivel de acceso:acceso abierto
Materia:in vitro pharmaceutical equivalence
high-resolution liquid chromatography
dissolution profiles difference factor (f1)
similarity factor (f2)
Equivalencia farmacéutica in vitro
cromatografía líquida de alta resolución
perfiles de disolución
factor de diferencia (f1)
factor de similitud (f2)
Descripción
Sumario:Pharmaceutical equivalence in vitro four medicines containing paracetamol, maleate chlorpheniramine and phenylephrine hydrochloride tablets using Chromatography Liquid High Resolution reversed phase (HPLC-RP) is called, the dissolution profiles of the reference product and were determined 4 products in the study also were established and compared the differences in the dissolution profiles of the reference product and the products under study. The design methodology was analytical, experimental and comparative. Four formulations marketed in Lima and the reference product was evaluated by the method of high performance liquid chromatography (HPLC). the dissolution profiles were measured and were compared using a statistical method independent model difference factor (f1) and similarity (f2), which revealed that the dissolution curves are different between products reference laboratory and laboratories analyzed, since f1 and f2 were outside the ranges established in two of the four formulations tested. The results showed that two of the four products tested by this method would not be pharmaceutical equivalents.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).