A physicochemical characterization was conducted for samples of rich triethylenglycol RTEG(contacted with natural gas and moisture), poor glycol PTEG (without moisture) and water ofcondensation taken from a cryogenic unit TWC. Tests of linear polarization resistance (LPR)and Tafel polarization curve...

Descripción completa

Detalles Bibliográficos
Autores: Castellanos, Esteban, Díaz-Tang, Isabel
Formato: artículo
Fecha de Publicación:2015
Institución:Sociedad Química del Perú
Repositorio:Revista de la Sociedad Química del Perú
Lenguaje:español
OAI Identifier:oai:rsqp.revistas.sqperu.org.pe:article/14
Enlace del recurso:http://revistas.sqperu.org.pe/index.php/revistasqperu/article/view/14
Nivel de acceso:acceso abierto
Materia:Glycol neutralizer
corrosion inhibitor
triethylenglycol
sulfur
Neutralizador de glicol
inhibidor de corrosión
trietilenglicol
azufre
Descripción
Sumario:A physicochemical characterization was conducted for samples of rich triethylenglycol RTEG(contacted with natural gas and moisture), poor glycol PTEG (without moisture) and water ofcondensation taken from a cryogenic unit TWC. Tests of linear polarization resistance (LPR)and Tafel polarization curves were performed to determine the corrosion rate of RTEG,PTEG and TWR (Teg water removed) and the corrosion inhibitor (Coastal 1755) efficiencyat different concentrations for static conditions. One rotating ring electrode coupled to apotentiostat galvanostat Autolab/PGSTAT 302N was used for evaluation, using procedures inaccordance with ASTM G-170- 01, “Standard Guide for Evaluating and Qualifying Oil Fieldand Refinery Corrosion Inhibitors in the Laboratory “.The corrosion deposit extracted from the drainage system was characterized by an emissionspectrometer, brand Jarrel Ash and x-ray diffraction brand Phillips. Corrosion rate of process water without inhibitor injection is in the order of 4 mpy (0.114 mm/ year) and for mixtures of triethylenglycol are considered negligible therefore Coastal 1755-C inhibitor is neutralizing acidity and controlling corrosion in the system.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).