Environmental and Ambient Vibration Monitoring of Historical Adobe Buildings: Applications in Emblematic Andean Churches
Descripción del Articulo
This paper presents the application of long-term environmental and structural remote monitoring in two emblematic 16th-century adobe churches located in southern Peru. The paper starts by presenting details of the planning and installation processes of the monitoring systems and continues with a det...
Autores: | , , , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2019 |
Institución: | Consejo Nacional de Ciencia Tecnología e Innovación |
Repositorio: | CONCYTEC-Institucional |
Lenguaje: | inglés |
OAI Identifier: | oai:repositorio.concytec.gob.pe:20.500.12390/2757 |
Enlace del recurso: | https://hdl.handle.net/20.500.12390/2757 https://doi.org/10.1080/15583058.2019.1653402 |
Nivel de acceso: | acceso abierto |
Materia: | structural monitoring Adobe buildings Andean churches correlation analysis environmental monitoring http://purl.org/pe-repo/ocde/ford#5.07.01 |
id |
CONC_be36b679f2c0858156ca170b57dd9407 |
---|---|
oai_identifier_str |
oai:repositorio.concytec.gob.pe:20.500.12390/2757 |
network_acronym_str |
CONC |
network_name_str |
CONCYTEC-Institucional |
repository_id_str |
4689 |
dc.title.none.fl_str_mv |
Environmental and Ambient Vibration Monitoring of Historical Adobe Buildings: Applications in Emblematic Andean Churches |
title |
Environmental and Ambient Vibration Monitoring of Historical Adobe Buildings: Applications in Emblematic Andean Churches |
spellingShingle |
Environmental and Ambient Vibration Monitoring of Historical Adobe Buildings: Applications in Emblematic Andean Churches Zonno G. structural monitoring Adobe buildings Andean churches correlation analysis environmental monitoring http://purl.org/pe-repo/ocde/ford#5.07.01 |
title_short |
Environmental and Ambient Vibration Monitoring of Historical Adobe Buildings: Applications in Emblematic Andean Churches |
title_full |
Environmental and Ambient Vibration Monitoring of Historical Adobe Buildings: Applications in Emblematic Andean Churches |
title_fullStr |
Environmental and Ambient Vibration Monitoring of Historical Adobe Buildings: Applications in Emblematic Andean Churches |
title_full_unstemmed |
Environmental and Ambient Vibration Monitoring of Historical Adobe Buildings: Applications in Emblematic Andean Churches |
title_sort |
Environmental and Ambient Vibration Monitoring of Historical Adobe Buildings: Applications in Emblematic Andean Churches |
author |
Zonno G. |
author_facet |
Zonno G. Aguilar R. Boroschek R. Lourenço P.B. |
author_role |
author |
author2 |
Aguilar R. Boroschek R. Lourenço P.B. |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Zonno G. Aguilar R. Boroschek R. Lourenço P.B. |
dc.subject.none.fl_str_mv |
structural monitoring |
topic |
structural monitoring Adobe buildings Andean churches correlation analysis environmental monitoring http://purl.org/pe-repo/ocde/ford#5.07.01 |
dc.subject.es_PE.fl_str_mv |
Adobe buildings Andean churches correlation analysis environmental monitoring |
dc.subject.ocde.none.fl_str_mv |
http://purl.org/pe-repo/ocde/ford#5.07.01 |
description |
This paper presents the application of long-term environmental and structural remote monitoring in two emblematic 16th-century adobe churches located in southern Peru. The paper starts by presenting details of the planning and installation processes of the monitoring systems and continues with a detailed discussion of the results of almost two years of continuous monitoring. As expected, due to the large thermal inertia of the adobe systems and size of the buildings, the results of the environmental monitoring indicated a non-uniform distribution of temperature and relative humidity inside the buildings, and an important attenuation of the internal conditions in comparison with the external ones. On the other hand, the structural monitoring results evidenced an annual cyclical behavior of the natural frequencies with an apparent correspondence with the changes in environmental conditions due to seasonal influences. The correlation of ambient conditions and structural parameters confirmed the high affinity between relative humidity measurements and natural frequencies when hourly fluctuations were removed from the measurements. An important novelty is the affinity of structural dynamic properties and a single environmental variable, the absolute humidity, was also evidenced since high determination coefficients were obtained when it was compared with the identified natural frequencies. © 2019, © 2019 Taylor & Francis. |
publishDate |
2019 |
dc.date.accessioned.none.fl_str_mv |
2024-05-30T23:13:38Z |
dc.date.available.none.fl_str_mv |
2024-05-30T23:13:38Z |
dc.date.issued.fl_str_mv |
2019 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
dc.identifier.uri.none.fl_str_mv |
https://hdl.handle.net/20.500.12390/2757 |
dc.identifier.doi.none.fl_str_mv |
https://doi.org/10.1080/15583058.2019.1653402 |
dc.identifier.scopus.none.fl_str_mv |
2-s2.0-85071032483 |
dc.identifier.isi.none.fl_str_mv |
482164800001 |
url |
https://hdl.handle.net/20.500.12390/2757 https://doi.org/10.1080/15583058.2019.1653402 |
identifier_str_mv |
2-s2.0-85071032483 482164800001 |
dc.language.iso.none.fl_str_mv |
eng |
language |
eng |
dc.relation.ispartof.none.fl_str_mv |
International Journal of Architectural Heritage |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.publisher.none.fl_str_mv |
Taylor and Francis Inc. |
publisher.none.fl_str_mv |
Taylor and Francis Inc. |
dc.source.none.fl_str_mv |
reponame:CONCYTEC-Institucional instname:Consejo Nacional de Ciencia Tecnología e Innovación instacron:CONCYTEC |
instname_str |
Consejo Nacional de Ciencia Tecnología e Innovación |
instacron_str |
CONCYTEC |
institution |
CONCYTEC |
reponame_str |
CONCYTEC-Institucional |
collection |
CONCYTEC-Institucional |
repository.name.fl_str_mv |
Repositorio Institucional CONCYTEC |
repository.mail.fl_str_mv |
repositorio@concytec.gob.pe |
_version_ |
1844883036627271680 |
spelling |
Publicationrp00702600rp05603600rp00703600rp00704600Zonno G.Aguilar R.Boroschek R.Lourenço P.B.2024-05-30T23:13:38Z2024-05-30T23:13:38Z2019https://hdl.handle.net/20.500.12390/2757https://doi.org/10.1080/15583058.2019.16534022-s2.0-85071032483482164800001This paper presents the application of long-term environmental and structural remote monitoring in two emblematic 16th-century adobe churches located in southern Peru. The paper starts by presenting details of the planning and installation processes of the monitoring systems and continues with a detailed discussion of the results of almost two years of continuous monitoring. As expected, due to the large thermal inertia of the adobe systems and size of the buildings, the results of the environmental monitoring indicated a non-uniform distribution of temperature and relative humidity inside the buildings, and an important attenuation of the internal conditions in comparison with the external ones. On the other hand, the structural monitoring results evidenced an annual cyclical behavior of the natural frequencies with an apparent correspondence with the changes in environmental conditions due to seasonal influences. The correlation of ambient conditions and structural parameters confirmed the high affinity between relative humidity measurements and natural frequencies when hourly fluctuations were removed from the measurements. An important novelty is the affinity of structural dynamic properties and a single environmental variable, the absolute humidity, was also evidenced since high determination coefficients were obtained when it was compared with the identified natural frequencies. © 2019, © 2019 Taylor & Francis.Consejo Nacional de Ciencia, Tecnología e Innovación Tecnológica - ConcytecengTaylor and Francis Inc.International Journal of Architectural Heritageinfo:eu-repo/semantics/openAccessstructural monitoringAdobe buildings-1Andean churches-1correlation analysis-1environmental monitoring-1http://purl.org/pe-repo/ocde/ford#5.07.01-1Environmental and Ambient Vibration Monitoring of Historical Adobe Buildings: Applications in Emblematic Andean Churchesinfo:eu-repo/semantics/articlereponame:CONCYTEC-Institucionalinstname:Consejo Nacional de Ciencia Tecnología e Innovacióninstacron:CONCYTEC20.500.12390/2757oai:repositorio.concytec.gob.pe:20.500.12390/27572024-05-30 16:11:06.41http://purl.org/coar/access_right/c_14cbinfo:eu-repo/semantics/closedAccessmetadata only accesshttps://repositorio.concytec.gob.peRepositorio Institucional CONCYTECrepositorio@concytec.gob.pe#PLACEHOLDER_PARENT_METADATA_VALUE##PLACEHOLDER_PARENT_METADATA_VALUE##PLACEHOLDER_PARENT_METADATA_VALUE##PLACEHOLDER_PARENT_METADATA_VALUE#<Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="d9095dac-412e-4c43-a1f9-b992e2b48203"> <Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843</Type> <Language>eng</Language> <Title>Environmental and Ambient Vibration Monitoring of Historical Adobe Buildings: Applications in Emblematic Andean Churches</Title> <PublishedIn> <Publication> <Title>International Journal of Architectural Heritage</Title> </Publication> </PublishedIn> <PublicationDate>2019</PublicationDate> <DOI>https://doi.org/10.1080/15583058.2019.1653402</DOI> <ISI-Number>482164800001</ISI-Number> <SCP-Number>2-s2.0-85071032483</SCP-Number> <Authors> <Author> <DisplayName>Zonno G.</DisplayName> <Person id="rp00702" /> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> <Author> <DisplayName>Aguilar R.</DisplayName> <Person id="rp05603" /> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> <Author> <DisplayName>Boroschek R.</DisplayName> <Person id="rp00703" /> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> <Author> <DisplayName>Lourenço P.B.</DisplayName> <Person id="rp00704" /> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Taylor and Francis Inc.</DisplayName> <OrgUnit /> </Publisher> </Publishers> <Keyword>structural monitoring</Keyword> <Keyword>Adobe buildings</Keyword> <Keyword>Andean churches</Keyword> <Keyword>correlation analysis</Keyword> <Keyword>environmental monitoring</Keyword> <Abstract>This paper presents the application of long-term environmental and structural remote monitoring in two emblematic 16th-century adobe churches located in southern Peru. The paper starts by presenting details of the planning and installation processes of the monitoring systems and continues with a detailed discussion of the results of almost two years of continuous monitoring. As expected, due to the large thermal inertia of the adobe systems and size of the buildings, the results of the environmental monitoring indicated a non-uniform distribution of temperature and relative humidity inside the buildings, and an important attenuation of the internal conditions in comparison with the external ones. On the other hand, the structural monitoring results evidenced an annual cyclical behavior of the natural frequencies with an apparent correspondence with the changes in environmental conditions due to seasonal influences. The correlation of ambient conditions and structural parameters confirmed the high affinity between relative humidity measurements and natural frequencies when hourly fluctuations were removed from the measurements. An important novelty is the affinity of structural dynamic properties and a single environmental variable, the absolute humidity, was also evidenced since high determination coefficients were obtained when it was compared with the identified natural frequencies. © 2019, © 2019 Taylor & Francis.</Abstract> <Access xmlns="http://purl.org/coar/access_right" > </Access> </Publication> -1 |
score |
13.079572 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).